1. inherent energy of the tissues
2. closeness of molecular tumbling rate to Larmor frequency
3. how closely spaced the molecules are - Answers What are the 3 things factors that determine T1 and
T2 relaxation/decay times of tissues
T1, T2, PD, Flow
Apparent diffusion coefficient (ADC). - Answers What are the intrinsic parameters-
TR
TE
Flip angle
TI
Turbo factor/echo train length
b value. - Answers What are the extrinsic parameters -
T1 recovery is spin lattice relaxation, longitudinal magnetization regrowth - Answers What is T1 recovery
-
Loss of transverse magnetization due to spin-spin interaction/relaxation - Answers What is T2 decay?
white / bright - Answers High signal intensity/hyper-intensity appears -
black / dark - Answers Low signal intensity / hypointensity appears -
The TR is less than the T1 and T2 relaxation times of a tissue - Answers What is steady state -
parameters are selected to make one contrast dominate over the other.
IE: more T1 vs T2 or more T2 vs T1 - Answers Define the term weighting -
TE ; this determines how much dephasing is allowed to occur before the signal is read - Answers What
extrinsic parameter controls T2 decay, and why ?
The TR determines the amount of longitudinal relaxation that occurs between the end of one RF
excitation pulse and application of the next. - Answers What extrinsic parameter controls T1 relaxation,
and why ?
Permanent, resistive, superconducting - Answers What are the three basic types of magnets used to
construct MRI scanners?
, superconducting - Answers What is the most common type of MRI magnet in use today
Ferromagnetic attraction / missile effect - Answers One of the most important safety concerns
associated with MRI is:
Permanent - Answers What type of magnet cannot be turned off?
In certain life threatening emergencies - Answers Under what circumstances should a superconducting
magnet be turned off?
The MRI technologist - Answers The person responsible for the safety of everyone in and around the
MRI environment is:
False - Answers All wheelchairs, IV poles, and gurney are allowed in the MRI room
Isidor Rabi - Answers Who was the first person to demonstrate a radio signal from the nucleus of an
atom?
Bloch and Purcell - Answers Which two physicists first won a Nobel Prize in Physics for their
development of nuclear induction?
1952 - Answers In what year did these two individuals win this prize?
Raymond Damadian - Answers Who is credited with the first human body image in 1977?
1985 - Answers In what year did MRI receive its FDA approval?
Bloch - Answers Who is considered to be the father of MRI with their development of the T1 and T2
equations?
Nuclear Magnetic Resonance - Answers One of the original names for the technology, NMR, stood for
what?
Chemicals, spectroscopy - Answers What were the early NMR machines used to study, and what was the
name of this technique?
Indomitable" - Answers Raymond Damadian's first human-sized machine, now in the Smithsonian, is
named:
Nuclear disasters at the time.
To prevent patients from thinking it was ionizing radiation - Answers What prompted the name change
from NMR to MRI prior to FDA approval?
Hydrogen - Answers Which of the following is the most abundant atom in the human body?
Magnet, computer, operating console - Answers What are the three main components of an MRI
machine?