Exam
The sizing of grease traps should take into consideration the
___________________ and the ___________________________________. - ✔
✔ type of facility served and the
estimated daily sewage flow.
Grease traps may be constructed of ___________materials used for
conventional septic tanks. - ✔ ✔ any
It is recommended that grease traps be cleaned when ___________ percent of
their grease retention capacity is reached. - ✔ ✔ 75%
Commercial on-site sewage disposal systems shall adhere to all the standards
established for residential systems unless
__________________________________. - ✔ ✔ specifically addressed in the
permit.
, Commercial systems shall be sized according to the
______________________________________ for the facility to be served. - ✔
✔ anticipated daily sewage flow
For residential type facilities both single and multifamily, _________________
per bedroom will be used to estimate the number of gallons per day sewage
flow. - ✔ ✔ 150 gallons per bedroom
Where garbage grinders are used increase tank capacity by
__________________% - ✔ ✔ 50%
All solid pipe used in the installation of on-site sewage disposal systems shall be
schedule _________________ or equivalent. (cast Iron shall be considered to
meet the equivalency standard.) - ✔ ✔ 40 PVC
All wiring and electrical components for systems requiring electrical
components should for systems requiring electrical components should meet
the standards set forth in the ____________________________________. - ✔
✔ National Electrical Code
Trenches that exceed sixty inches in depth should have ___________ stabilized
with appropriate shoring devices. - ✔ ✔ Walls