NEC Journeyman Electrician Exam : 300+ Questions & Verified Answers (Pass Guaranteed)

Document preview thumbnail
Preview 4 out of 36 pages

Pass your Journeyman Electrician exam with this complete NEC-based question bank! Features 300+ practice questions with verified answers on conductors, load calculations, GFCI/AFCI rules, and electrical theory

Content preview

Journeyman Electrician Exam Questions &
Verified Answers.
1/4" ~CORRECT ANSWER~✓✓Threads of drainage fittings shall be tapped as to
allow _____ pitch per foot



4 lbs ~CORRECT ANSWER~✓✓Lead used for safe pans shall not be less than
________ per square foot



Copper Tube, Cast Iron, Stainless steel, ABS, PVC DWV ~CORRECT
ANSWER~✓✓Name 3 allowable materials for the DWV system "underground"



1-1/4" - 1 dfu's

1-1/2" - 3 dfu's

2" - 4 dfu's

3" 6 dfu's

4" - dfu's ~CORRECT ANSWER~✓✓What are the fixture unit values for the
following traps



Double fixture fitting ~CORRECT ANSWER~✓✓What type of fitting is used for
continuous waste and venting of lavatories back to back?



1" ~CORRECT ANSWER~✓✓Caulk joints for cast iron bell and spigot shall be
filled with molten lead to a depth of not less than ________?

,Wye, Combination Wye w/ 1/8 bend, Long sweep ~CORRECT
ANSWER~✓✓What type of fitting or fittings can be used to connect horizontal
drainage to another horizontal drainage line?



- Each horizontal drainage pipe shall be provided with a cleat at its upper
terminal

- Horizontal run more than 100'

- Each horizontal change of direction exceeding 135°

- Front Main Cleanout ~CORRECT ANSWER~✓✓Cleanout locations required by
code



100' ~CORRECT ANSWER~✓✓Maximum distance a cleanup can be spaced
apart



12"

18" ~CORRECT ANSWER~✓✓Minimum clearance in front of a cleanup for 2" or
less

Minimum clearance in front of a cleanup for 2" or more



20' ~CORRECT ANSWER~✓✓Underfloor cleanup shall not be located more than
_____ from an access door, trap door, or crawl hole



Back Water Valve ~CORRECT ANSWER~✓✓When plumbing fixtures are
installed on a floor level lower than the next upstream manhole cover of the
sewer, such drainage piping shall be protected from backflow of sewage by a
____________

,20 ~CORRECT ANSWER~✓✓Sewage ejectors receiving the discharge of water
closets or ruinals shall have a discharge capacity not less than ___ gallons per
minute



2" ~CORRECT ANSWER~✓✓What is the minimum size discharge pipe for an
ejector installed in a single dwelling?



2" ~CORRECT ANSWER~✓✓The lowest inlet connected to the ejector pump
shall have a clearance of not less than ____ from the high water or starting level
of the sump.



Yes, with prior approval of the AHJ ~CORRECT ANSWER~✓✓Can macerating
toilet systems be installed instead of a sewage pump system



3/4" ~CORRECT ANSWER~✓✓What is the minimum size discharge pipe for a
macerating toilet system



1/4" per foot ~CORRECT ANSWER~✓✓What is the minimum pitch required
fora 2" horizontal drain?



Swing check valve ~CORRECT ANSWER~✓✓The discharge line from an ejector
pump shall be provided with an accessible ___________ and gate or ball valve.



Downstream of the backwater valve ~CORRECT ANSWER~✓✓Where shall the
gate valve be located on the discharge line on an ejector pump

, 8' ~CORRECT ANSWER~✓✓Drainage connections shall not be made into a
drainage piping system within ________ of an vertical or horizontal change in
direction of a stack containing suds producing fixtures.



10' Head of water for 15 minutes

5 psi for and air test ~CORRECT ANSWER~✓✓What are the requirements when
testing the DWV system Water and Air?



When the dwelling is more than 200' away from the sewer. ~CORRECT
ANSWER~✓✓When is the public sewer considered not being available?



2' away from the building ~CORRECT ANSWER~✓✓At what point does the
building sewer begin?



DFU's ~CORRECT ANSWER~✓✓How is the size of the building sewer
determined?



300' ~CORRECT ANSWER~✓✓What is the maximum distance allowed between
approved manholes?



12" ~CORRECT ANSWER~✓✓When a water pipe and sewer pipe are placed in a
common trench what is the minimum distance above the top of the sewer line to
the bottom of the water pipe?

Document information

Uploaded on
June 26, 2025
Number of pages
36
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$14.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
PUREGRADES
4.5
(20)
Sold
130
Followers
5
Items
1123
Last sold
4 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions