S12 sprinkler Test Correct Questions And
Answers
________ NOZZLES ARE USED FOR TRANSFORMER VAULTS AND OTHER HAZARDOUS AREAS. - ANSWER-
b b b b b b b b b b b b
OPEN-FIXED
________ SYSTEMS ARE INSTALLED WHERE A WET PIPE SYSTEM CANNOT BE HEATED TO PREVENT
b b b b b b b b b b b b b
FREEZING. - ANSWER-DRY PIPE
b b b b
_________ ARE ABLE TO SUPPLY FEED MAINS OR CROSS MAINS DIRECTLY. - ANSWER-RISERS
b b b b b b b b b b b b
_________ SPRINKLERS HAVE BEEN RECALLED. - ANSWER-CYCLING
b b b b b b
_________ SYSTEMS ARE USED FOR THE PROTECTION OF SPECIAL HAZARDOUS OCCUPANCIES. -
b b b b b b b b b b b
ANSWER-FOAM SUPPLY
b b
_________ SYSTEMS ARE USUALLY FOUND IN BASEMENTS OR OTHER DIFFICULT TO REACH AREAS. -
b b b b b b b b b b b b b
ANSWER-PERFORATED PIPE
b b
__________ SHALL BE POSTED ON THE TAG INDICATING BOTH STATIC AND FLOW PRESSURES BEFORE
b b b b b b b b b b b b b
AND AFTER. - ANSWER-DRAIN TEST RESULTS
b b b b b b
__________ SHALL BE READILY AVAILABLE TO ANY REPRESENTATIVE OF THE FIRE DEPT. THESE ARE TO BE
b b b b b b b b b b b b b b b
MAINTAINED ON SITE FOR 3 YEARS. - ANSWER-RECORDS
b b b b b b b b
__________ SHALL NOT BE USED TO FASTEN THE SYSTEM OR BUILDING ATTACHMENTS TO THE
b b b b b b b b b b b b b
STRUCTURE. - ANSWER-NAILS
b b b
__________ TANKS ARE MADE OF WOOD, STEEL, OR CONCRETE. - ANSWER-GRAVITY
b b b b b b b b b b
__________ VALVES ARE NO LONGER PERMITTED TO BE INSTALLED. - ANSWER-COLD WEATHER
b b b b b b b b b b b
___________ ARE DESIGNED TO TAKE WATER FROM A SUPPLY AND DISCHARGE IT UNDER PRESSURE. -
b b b b b b b b b b b b b b
ANSWER-FIRE PUMPS
b b
____________ LINES ARE DIRECTLY CONNECTED TO SPRINKLER HEADS. - ANSWER-BRANCH
b b b b b b b b b
A _______ SHALL BE REQUIRED TO POST TAGS AT MAIN CONTROL VALVE AND ANY SECTIONAL VALVES. -
b b b b b b b b b b b b b b b b
ANSWER-MASTER FIRE SUPPRESSION PIPING CONTRACTOR
b b b b b
A ________ CAN INSPECT, MAINTAIN, TEST, AND REPAIR ALL FIRE STANDPIPE AND SPRINKLER SYSTEMS. -
b b b b b b b b b b b b b b
ANSWER-MASTER FIRE SUPPRESSION PIPING CONTRACTOR (MFSPC)
b b b b b b
A ________ DISC OF 8-9 INCHES SHALL BE PLACED ON CONNECTIONS TO INDICATE THE SYSTEM IS
b b b b b b b b b b b b b b b
PARTIALLY OUT OF SERVICE. - ANSWER-BLUE
b b b b b b
, A _________ DISC OF 8-9 INCHES SHALL BE PLACED ON CONNECTIONS TO INDICATE THE SYSTEM IS
b b b b b b b b b b b b b b b
FULLY OUT OF SERVICE. - ANSWER-WHITE
b b b b b b
A MASTER PLUMBER (MP) WITH COF IS LIMITED TO RESIDENTIAL OCCUPANCIES WITH _________
b b b b b b b b b b b b
SPRINKLER HEADS OR LESS. - ANSWER-30
b b b b b b
A MINIMUM OF _________ EXTRA SPRINKLER HEADS WITH THE APPROPRIATE WRENCHES SHALL BE
b b b b b b b b b b b b
AVAILABLE TO REPLACED DAMAGED ONES - ANSWER-6
b b b b b b b
A SIGN INDICATING THE LOCATION OF ALL _______ SHALL BE KEPT IN THE COMPACTOR ROOM. -
b b b b b b b b b b b b b b b
ANSWER-CONTROL VALVES
b b
A VERTICAL TURBINE PUMP IS USED TO DRAW WATER FROM A WELL TO ___________. - ANSWER-FILL A
b b b b b b b b b b b b b b b b
STORAGE TANK.
b b
ABOUT ______ PERCENT OF FIRES ARE EXTINGUISHED OR CONTROLLED WHEN SPRINKLERS ARE
b b b b b b b b b b b
INSTALLED. - ANSWER-96
b b b
Alarm Retarding Devices - ANSWER-An alarm check valve that is exposed to changing water supply
b b b b b b b b b b b b b b
pressure needs an alarm retarding device. This is required to prevent false alarms when the check valve
b b b b b b b b b b b b b b b b b
clapper is lifted from its seat by a temporary pressure surge. Vane type water flow switches sensitivity
b b b b b b b b b b b b b b b b b
can also be adjusted to changing water pressures.
b b b b b b b b
ALL INDICATING VALVES IN THE COMPACTOR SPRINKLER SYSTEM SHALL BE ________ OPEN. - ANSWER-
b b b b b b b b b b b b b
SEALED
AN ACCELERATOR AND EXHAUSTER ARE USED TO _______THE TIME TO ALLOW WATER INTO THE
b b b b b b b b b b b b b
SYSTEM. - ANSWER-REDUCE
b b b
AT A DISTANCE OF 4 FEET BELOW THE DEFLECTOR, THE SPRAY PATTERN COVERS A DIAMETER OF
b b b b b b b b b b b b b b b
_________ FEET WHEN DISCHARGING AT 15 GPM. - ANSWER-16
b b b b b b b b b
AUTOMATIC BALL DRIP DEVICES SHALL BE INSTALLED IN THE _________ POSITION. - ANSWER-
b b b b b b b b b b b b
HORIZONTAL
AUTOMATIC FILL PUMPS FILL THE TANK AT A RATE OF _________ GPM OR MORE. - ANSWER-65
b b b b b b b b b b b b b b b
Automatic fill pumps supply the water to most gravity tanks. The pumps fill the tank at a rate of __ gpm -
b b b b b b b b b b b b b b b b b b b b b
ANSWER-65
b
AUTOMATIC FIRE PUMPS ARE USUALLY NEEDED WHERE A ___________ MAY OCCUR IMMEDIATELY. -
b b b b b b b b b b b b
ANSWER-HIGH WATER DEMAND
b b b
blue disk - ANSWER-partially out of service- on all fire department connections
b b b b b b b b b b b
Booster pumps/special service pumps - ANSWER-Booster pumps are sometimes used in sprinkler
b b b b b b b b b b b
systems. They small pumps with limited power are usually located in the basement or taking suction
b b b b b b b b b b b b b b b b
from gravity tanks. The booster pump is used when the water pressure available at the highest sprinkler
b b b b b b b b b b b b b b b b b
head does not quite meet the needs of the sprinkler system. This small pump increases the water
b b b b b b b b b b b b b b b b b
pressure in the sprinkler system until it reaches acceptable levels. The booster pump should not be
b b b b b b b b b b b b b b b b
confused with the fire pump or the jockey pump.
b b b b b b b b b