KENTUCKY PESTICIDE CATEGORY 11:
AERIAL EXAM GRADED A+
Dosage d- dcorrect danswers d-- dAmount dof dchemical dabsorbed.
- dSize dof dthe dorganism dreceiving dthe dchemical.
Toxicity d- dcorrect danswers d-The dinherent dcapability dof da dchemical dsubstance dto
dcause dinjury.
LD50 d- dcorrect danswers d-Lethal ddosage dlikely dto dkill d50% dof dthe dtest dorganism.
d
50 dppm dor dless d= dHighly dHazardous d(Dangerous).
51 dto d500 dppm d= dModerately dHazardous d(Warning).
501 dto d5000 dppm d= dSlightly dHazardous d(Caution).
More dthan d5000 dppm d= dRelatively dNonhazardous.
Signs dvs. dSymptoms d- dcorrect danswers d--Signs d= dVisible dindication dof dpoisoning
dthat danother dcan dSEE din da dvictim. d
, -Symptoms d= dInvisible devidence dof dpoisoning dthat donly dthe dvictim dcan dFEEL.
Medical dAntidotes d- dcorrect danswers d-Only dprescribed dand dadministered dby
dqualified dphysicians.
Spray dTank dLocation d- dcorrect danswers d-Mounted din dfront dof dthe dcockpit dand das
dclose das dpossible dto dthe dcenter dof dgravity.
Most dwidely dused dspray dpump dtype? d- dcorrect danswers d-Centrifugal dPump
Centrifugal dPump dvs. dGear dPump d- dcorrect danswers d-Centrifugal:
- dHigh dGPM drate dwhile dworking dagainst dLOW dpressure d(25 dto d50 dpsi). d
Gear:
- dLow dGPM drate dwhile dworking dagainst dHIGH dpressure d(>60 dpsi).
- dWeighs dmore dthan dcentrifugal.
Pesticides drequiring dconstant dagitation? d- dcorrect danswers d-- dWettable dPowders
- dFlowables
Pipe dsizing dfor dfixed dwing dvs. drotary d- dcorrect danswers d-Fixed dWing d= d2 dinch
Rotary d= d1 dinch
Spray dsystem dhoses dare dless dlikely dto daccidently dseparate dfrom dfittings dif dthey
dare? d- dcorrect danswers d-Barbed dhoses, ddouble dclamped dor dboth.
Maximum dBoom dLength don dAirplane dvs. dRotorcraft d- dcorrect danswers d-Airplane
d= d70% dof dthe dwingspan. d
Rotorcraft d= d80% dof dthe drotor ddiameter.
Nozzle dClassifications d- dcorrect danswers d-Conventional d= d5 dto d15 dor dmore dGPA
Low dVolume d(LV) d= d0.5 dto d5 dGPA
Ultra dLow dVolume d(ULV) d= dLess dthan d0.5 dGPA
In dorder dto ddouble dthe doutput drate dyou dmust? d- dcorrect danswers d-Quadruple dthe
dpressure.
Ram dAir dSpreader dVanes d- dcorrect danswers d-- dThe dtop dof deach dvane dMUST
dcontact dthe dupper dskin
- dFWD dand dAFT dportions dare dadjustable. d
- dTo dcounteract dpropwash dthe dspreader dvanes dshould dbe dpositioned dmore dleft
dto dallow dmore dflow dof dmaterial don dthe dright. d
- dOrientation dshould dnever dexceed d15 ddegrees dangle dof dincidence. d
- dAs dthe drate dincreases, dthe dswath dwidth ddecreases. d
- dMaximum dof d35 dpounds dper dsecond
AERIAL EXAM GRADED A+
Dosage d- dcorrect danswers d-- dAmount dof dchemical dabsorbed.
- dSize dof dthe dorganism dreceiving dthe dchemical.
Toxicity d- dcorrect danswers d-The dinherent dcapability dof da dchemical dsubstance dto
dcause dinjury.
LD50 d- dcorrect danswers d-Lethal ddosage dlikely dto dkill d50% dof dthe dtest dorganism.
d
50 dppm dor dless d= dHighly dHazardous d(Dangerous).
51 dto d500 dppm d= dModerately dHazardous d(Warning).
501 dto d5000 dppm d= dSlightly dHazardous d(Caution).
More dthan d5000 dppm d= dRelatively dNonhazardous.
Signs dvs. dSymptoms d- dcorrect danswers d--Signs d= dVisible dindication dof dpoisoning
dthat danother dcan dSEE din da dvictim. d
, -Symptoms d= dInvisible devidence dof dpoisoning dthat donly dthe dvictim dcan dFEEL.
Medical dAntidotes d- dcorrect danswers d-Only dprescribed dand dadministered dby
dqualified dphysicians.
Spray dTank dLocation d- dcorrect danswers d-Mounted din dfront dof dthe dcockpit dand das
dclose das dpossible dto dthe dcenter dof dgravity.
Most dwidely dused dspray dpump dtype? d- dcorrect danswers d-Centrifugal dPump
Centrifugal dPump dvs. dGear dPump d- dcorrect danswers d-Centrifugal:
- dHigh dGPM drate dwhile dworking dagainst dLOW dpressure d(25 dto d50 dpsi). d
Gear:
- dLow dGPM drate dwhile dworking dagainst dHIGH dpressure d(>60 dpsi).
- dWeighs dmore dthan dcentrifugal.
Pesticides drequiring dconstant dagitation? d- dcorrect danswers d-- dWettable dPowders
- dFlowables
Pipe dsizing dfor dfixed dwing dvs. drotary d- dcorrect danswers d-Fixed dWing d= d2 dinch
Rotary d= d1 dinch
Spray dsystem dhoses dare dless dlikely dto daccidently dseparate dfrom dfittings dif dthey
dare? d- dcorrect danswers d-Barbed dhoses, ddouble dclamped dor dboth.
Maximum dBoom dLength don dAirplane dvs. dRotorcraft d- dcorrect danswers d-Airplane
d= d70% dof dthe dwingspan. d
Rotorcraft d= d80% dof dthe drotor ddiameter.
Nozzle dClassifications d- dcorrect danswers d-Conventional d= d5 dto d15 dor dmore dGPA
Low dVolume d(LV) d= d0.5 dto d5 dGPA
Ultra dLow dVolume d(ULV) d= dLess dthan d0.5 dGPA
In dorder dto ddouble dthe doutput drate dyou dmust? d- dcorrect danswers d-Quadruple dthe
dpressure.
Ram dAir dSpreader dVanes d- dcorrect danswers d-- dThe dtop dof deach dvane dMUST
dcontact dthe dupper dskin
- dFWD dand dAFT dportions dare dadjustable. d
- dTo dcounteract dpropwash dthe dspreader dvanes dshould dbe dpositioned dmore dleft
dto dallow dmore dflow dof dmaterial don dthe dright. d
- dOrientation dshould dnever dexceed d15 ddegrees dangle dof dincidence. d
- dAs dthe drate dincreases, dthe dswath dwidth ddecreases. d
- dMaximum dof d35 dpounds dper dsecond