Propane\\ACTUAL EXAM \NEWEST VERSION
2025-2026 \COMPLETE QUESTIONS AND
ACCURATE DETAILED ANSWERS \VERIFIED
SOLUTIONS ALREADY GRADED A+
Increasing gas rate causes... flow velocity to increase
915 mm horizontally from any appliance exhaust
A fuel filler must be 36" horizontally from any appliance exhaust
located:
A propane regulator shall with its vent facing downloads at a 45 degree angle or
be mounted... less from vertical
Tubing and piping may be The area is not used for heating or return air ducts
routed through the chassis The area is not insulated
provided
How many cubic feet of 50 cu, Ft
oxygen are needed to
burn 10 cubic feet of
propane
Type K, L, and GP may be in size from 3/8" to 3/4" only
used for
1/18
,6/24/25, 8:16 PM Propane
The two types of flames luminous and bunsen
are
POL hoses are certified 350 psig
for what pressure?
What is required if road Has to be protected
hazards may damage the
tubing of a propane
system?
What must be done when cap and plug the lines
an appliance is removed
from a coach for
servicing?
What is the working 11" wc
pressure required when
testing a regulator?
What pressure should you 8"
use when doing a leak
test?
2/18
, 6/24/25, 8:16 PM Propane
3/18