1- Which of the following factors below does not affect heat transfer - Correct Answer Density. 2-An example of a poor conductor of heat is. -Correct Answer Wood. 3- Thermal conductivity ('k') is -Correct Answer The number of BTUs that will pass in one hour through a material 1'' thick with an area 1ft2 if the temperature difference from one side to the other is 1'f 4-Which is not a source of fouling of a heat exchanger surface -Correct Answer Water. 5- Which is a true statement -Correct Answer The higher the k factor the greater the thermal conductivity6- Optimum U factor for the given material that the heat exchanger is made of the results when -Correct Answer There is no impeding substance such as ice dirt or oil on the surfaces of the heat exchanger tubes.

Content preview

Reta Book 2 Chapter 1 Exam Test

1- Which of the following factors below does not affect heat transfer -

Correct Answer ✔ ✔ Density.


2-An example of a poor conductor of heat is. -Correct Answer ✔ ✔

Wood.


3- Thermal conductivity ('k') is -Correct Answer ✔ ✔ The number

of BTUs that will pass in one hour through a material 1'' thick with an

area 1ft2 if the temperature difference from one side to the other is

1'f


4-Which is not a source of fouling of a heat exchanger surface -Correct

Answer ✔ ✔ Water.


5- Which is a true statement -Correct Answer ✔ ✔ The higher the

k factor the greater the thermal conductivity

, 6- Optimum U factor for the given material that the heat exchanger is

made of the results when -Correct Answer ✔ ✔ There is no

impeding substance such as ice dirt or oil on the surfaces of the heat

exchanger tubes.


7- When air flow is decreased across a heat exchange surface,cooling

capacity is -Correct Answer ✔ ✔ Reduced


8-Centrifugal fans have advantage over propeller fans in that

they............ than prop fans. -Correct Answer ✔ ✔ Are quieter


9-The operating engineer -Correct Answer ✔ ✔ Cannot change the

K factor of the metal but has some control of the overall U factor for

the evaporator as a unit.


10-The limiting factor of an evaporator's capacity that the operator

can't control is -Correct Answer ✔ ✔ Evaporator size.

Document information

Uploaded on
June 23, 2025
Number of pages
9
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$8.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
jackline98
3.3
(61)
Sold
272
Followers
152
Items
9892
Last sold
2 months ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions