QUESTIONS AND CORRECT ANSWERS
12-24v - CORRECT ANSWER✅✅What is the input voltage range of the Doorbell Cam?
16.5 VAC - CORRECT ANSWER✅✅What is the output voltage of the transformer used
to power the SkyControl panel?
true - CORRECT ANSWER✅✅True or False: When programming a sensor into the sky
panel you can type in the serial number or "learn" it in by triggering the device
2 - CORRECT ANSWER✅✅When programming a DW21, which loop number is used?
1
2
3
beans and wire caps - CORRECT ANSWER✅✅Which of the following materials can you
use to group multiple ground terminals in a takeover module:
Solder
String
Wire Caps
Duct Tape
Beans
True - CORRECT ANSWER✅✅T or F: When installing the firefighter, it is required to
test the customer's existing smoke detectors
3/4" - CORRECT ANSWER✅✅When installing a DW21, what size bit should you use to
drill the hole for the sensor?
1/2"
3/8"
3/4"
1"
True - CORRECT ANSWER✅✅T or F: When installing the TAKE-345, you must ensure
that the transformer is supplying power to the power supply before the battery.
True - CORRECT ANSWER✅✅T or F: You are required to test signals from all
secondary keypads and key fobs even though they are not detection devices
False - CORRECT ANSWER✅✅T or F: When running power to the TAKE-345 polarity
does not apply
- CORRECT ANSWER✅✅What is the correct height at which to install the PIR2?
7 ft
At least 5 ft
, At least 7 ft
At 7.5 ft
How would you program a CO3 if mounted on a hallway wall?
Loop 1 Zone 8
Loop 1 Zone 14
Loop 3 Zone 4
Loop 1 Zone 4 - CORRECT ANSWER✅✅
When installing a DW21 into a metal door frame, with a wooden door, what should you be
sure to use?
Metal Drill bit
A DW11 should be used on all metal door frames
3/4" insulated magnet
Eye goggles - CORRECT ANSWER✅✅
True - CORRECT ANSWER✅✅T or F: Panic Pendants are programmed as an audible
alarm
T or F: The Firefighter may be installed next to a stand-alone battery-powered smoke detector
- CORRECT ANSWER✅✅
Which of the following zone/sensor types are correct when programming an SMKT3?
Type 9 - Freeze Detect
Type 7 - Freeze Detect
Type 9 - Heat detect
Type 6 - heat detect
type 1 - heat detect
type 8 - freeze detect
type 5 - smoke detect
type 7 - smoke detect
type 9 - smoke detect - CORRECT ANSWER✅✅
When installing a DW21 where is the approved location for the sensor?
Anywhere in the door
between 6"(15 cm) and 2' (61 cm) from floor
Below 6" from the floor
Top of the door - CORRECT ANSWER✅✅
T or F: When performing a full system test, you may bypass any open doors or windows -
CORRECT ANSWER✅✅
T or F: When installing a translator, you must program all of the existing sensors as new
equipment on the panel - CORRECT ANSWER✅✅
When programming a DW11 that has been installing on a window, which zone/sensor type
should you use?
10
01