✔✔How many joules can the Zoll deliver? - ✔✔1-200J
✔✔What are the four ways to disarm the charge setting on the Zoll? - ✔✔change the
energy, wait 60 seconds, disarm the zoll, turn it off
✔✔What are the two ways to pace a patient - ✔✔sync and demand
✔✔what doe the AECM do to the zoll between pts? - ✔✔turn off and wait two minutes
✔✔What are the zoll settings for syncing pt rhythm? - ✔✔40-80 output; 100 intrinsic
✔✔What are the two ways to determine pacing capture? - ✔✔electrical-pacer spikes
and mechanical-pulse
✔✔Zoll MD warning - ✔✔pads should be appropriate size for the pt
✔✔What is one caution for the Zoll MD - ✔✔to assure protection for discharge, use only
zoll approved accessories
✔✔Restraints purpose - ✔✔provide physical restraint
✔✔one WARNING for restraints - ✔✔make sure the keys are compatible
✔✔How many people minimum does it take to restrain a patient - ✔✔3 people min
✔✔Where can you NOT restrain pts - ✔✔litters or aircraft parts
✔✔When a pt is restrainted, what should they be able to do? - ✔✔touch their nose
✔✔Where can you place an IO? - ✔✔proximal humorous, proximal tibia and distance
tibia
✔✔How many places in total can you place an IO - ✔✔6 places
✔✔How can you check if the IO is the appropriate size? - ✔✔push down to the bone; if
the black line shows; drill
✔✔ AFI 11-2AEV3 - ✔✔Policy that governs AE operations and procedures
✔✔AFI 10-2909 - ✔✔Policy that governs approved medical equipment for flight;
Approved by AMC/A3VM
, ✔✔AMC - ✔✔Who is the waiver authority?
✔✔Will and Shall - ✔✔mandatory requirement
✔✔Should - ✔✔Preferred but not mandatory
✔✔May - ✔✔acceptable or suggested
✔✔Warning - ✔✔Loss of life/personal injury
✔✔Caution - ✔✔Damage to equipment
✔✔Note - ✔✔essential to emphasize
✔✔AF Form 4033 - ✔✔Certified to fly label; orange sticker
✔✔AF Form 368 or DD Form 2163 - ✔✔Maintenance Sticker; calibrated, operational
and ready for flight. Yellow sticker
✔✔Equipment Malfunction procedure - ✔✔Notify MTF
AFTO 350-repairable item tag
DD form 2852-near miss
Notify pilot IF aircraft will be effected
✔✔AWIS purpose - ✔✔communicate with AE crew members and CCATT
✔✔AWIS power - ✔✔two AA batteries (noise cancelling device)
✔✔trans receiver power - ✔✔3 AA batteries or NiMH (rechargeable batteries)
identify which and place switch correctly
✔✔AWIS placement - ✔✔headset on head; trans receiver on body
✔✔Operational pre-flight - ✔✔ensure all items are present and serviceable within 24 hrs
of the mission; per AFI 10-2909
✔✔Function Check - ✔✔modified pre-flight performed on aircraft power
✔✔Electronic Flight Bag (EFB) purpose - ✔✔ipad that carries all AE publications
approved by AMC
✔✔EFB power - ✔✔50-60Hz household power
WITH ANSWERS RATED A+
✔✔How many joules can the Zoll deliver? - ✔✔1-200J
✔✔What are the four ways to disarm the charge setting on the Zoll? - ✔✔change the
energy, wait 60 seconds, disarm the zoll, turn it off
✔✔What are the two ways to pace a patient - ✔✔sync and demand
✔✔what doe the AECM do to the zoll between pts? - ✔✔turn off and wait two minutes
✔✔What are the zoll settings for syncing pt rhythm? - ✔✔40-80 output; 100 intrinsic
✔✔What are the two ways to determine pacing capture? - ✔✔electrical-pacer spikes
and mechanical-pulse
✔✔Zoll MD warning - ✔✔pads should be appropriate size for the pt
✔✔What is one caution for the Zoll MD - ✔✔to assure protection for discharge, use only
zoll approved accessories
✔✔Restraints purpose - ✔✔provide physical restraint
✔✔one WARNING for restraints - ✔✔make sure the keys are compatible
✔✔How many people minimum does it take to restrain a patient - ✔✔3 people min
✔✔Where can you NOT restrain pts - ✔✔litters or aircraft parts
✔✔When a pt is restrainted, what should they be able to do? - ✔✔touch their nose
✔✔Where can you place an IO? - ✔✔proximal humorous, proximal tibia and distance
tibia
✔✔How many places in total can you place an IO - ✔✔6 places
✔✔How can you check if the IO is the appropriate size? - ✔✔push down to the bone; if
the black line shows; drill
✔✔ AFI 11-2AEV3 - ✔✔Policy that governs AE operations and procedures
✔✔AFI 10-2909 - ✔✔Policy that governs approved medical equipment for flight;
Approved by AMC/A3VM
, ✔✔AMC - ✔✔Who is the waiver authority?
✔✔Will and Shall - ✔✔mandatory requirement
✔✔Should - ✔✔Preferred but not mandatory
✔✔May - ✔✔acceptable or suggested
✔✔Warning - ✔✔Loss of life/personal injury
✔✔Caution - ✔✔Damage to equipment
✔✔Note - ✔✔essential to emphasize
✔✔AF Form 4033 - ✔✔Certified to fly label; orange sticker
✔✔AF Form 368 or DD Form 2163 - ✔✔Maintenance Sticker; calibrated, operational
and ready for flight. Yellow sticker
✔✔Equipment Malfunction procedure - ✔✔Notify MTF
AFTO 350-repairable item tag
DD form 2852-near miss
Notify pilot IF aircraft will be effected
✔✔AWIS purpose - ✔✔communicate with AE crew members and CCATT
✔✔AWIS power - ✔✔two AA batteries (noise cancelling device)
✔✔trans receiver power - ✔✔3 AA batteries or NiMH (rechargeable batteries)
identify which and place switch correctly
✔✔AWIS placement - ✔✔headset on head; trans receiver on body
✔✔Operational pre-flight - ✔✔ensure all items are present and serviceable within 24 hrs
of the mission; per AFI 10-2909
✔✔Function Check - ✔✔modified pre-flight performed on aircraft power
✔✔Electronic Flight Bag (EFB) purpose - ✔✔ipad that carries all AE publications
approved by AMC
✔✔EFB power - ✔✔50-60Hz household power