• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 4 out of 45 pages
Exam (elaborations)

RAC Practice Exam 2025|Actual Exam Test(MULTIPLE CHOICES) and (RATIONALES) questions and verified answers |GET IT 100% ACCURATE!!

Document preview thumbnail
Preview 4 out of 45 pages

RAC Practice Exam 2025|Actual Exam Test(MULTIPLE CHOICES) and (RATIONALES) questions and verified answers |GET IT 100% ACCURATE!!

Content preview

RAC Practice Exam 2025|Actual Exam Test(MULTIPLE CHOICES) and
2009 RAC Practice Exam
(RATIONALES) questions and verified answers |GET IT 100%
Study online at https://quizlet.com/_1es8x3
ACCURATE!!
1. A physician reports to a manufacturer C. 30 calendar days.
that a patient was hospitalized with
acute sepsis after treatment with an Serious injury must be reported within 30 days. 21
approved device. This side effect is CFR 803.50(a).
not listed in the package insert. This
event must be reported by the manu-
facturer to FDA no later than:

A. 5 calendar days.
B. 15 calendar days.
C. 30 calendar days.
D. The next quarterly or annual re-
port.

2. Under the IDE regulation, all of the C. An unanticipated adverse device effect.
following must be reported to the
sponsor within five working days EX- The investigator notifies the sponsor and IRB with-
CEPT: in 10 days of notification of any unanticipated ad-
verse effect. 21 CFR 812.150.
A. A deviation from the investigational
plan.
B. Withdrawal of IRB approval.
C. An unanticipated adverse device ef-
fect.
D. Use of a device without informed
consent.

3. When design verification testing is C. Identification of test methods used.
being performed by a manufactur-
er, which element is NOT included Refer to 820.30(f)
as a potential requirement under de-
vice design verification section of the



, 2009 RAC Practice Exam
Study online at https://quizlet.com/_1es8x3

QSR?

A. Identification of the design.
B. Software validation.
C. Identification of test methods
used.
D. Name of individuals performing
the testing.

4. Under the statutory violations, lack of A. Adulteration
an approved PMA for a PMA device
that is not exempt and is in commer- PMA products introduced into commercial distrib-
cial distribution is considered to be: ution without an approval PMA are considered to
be adulterated. FD&C Act 501(f).
A. Adulteration
B. Improper use
C. Misbranded
D. Fraudulent

5. A manufacturer of the following must C. A custom device being studied for safety and
file an IDE before conducting a hu- effectiveness.
man clinical study?
While a custom device may be studied in humans
A. A device in commercial distribu- without an IDE, if its safety and efficacy are being
tion before 28 May 1976 when used studied in support of commercial marketing, an
or investigated in accordance with its IDE must be filed (21 CFR 812.2(c)(7)
indications in labeling in effect at that
time.
B. A device intended solely for veteri-
nary use.
C. A custom device being studied for
safety and effectiveness.



, 2009 RAC Practice Exam
Study online at https://quizlet.com/_1es8x3

D. A device in commercial distribu-
tion before 28 May 1976 when used
or investigated in accordance with its
indications in labeling in effect at that
time. And a device intended solely for
veterinary use.

6. The regulatory affairs professional A. Preparing criteria for the MDR report.
performs all of the following prior to
submitting a PMA to FDA EXCEPT: MDR reporting is a post PMA approval require-
ment.
A. Preparing criteria for the MDR re-
port.
B. Preparing a brief statement of rea-
sons for noncompliance with regula-
tion.
C. Identifying all omissions in PMA
content.
D. Reviewing, organizing and check-
ing adequacy of data pertaining to
safety and efficacy evaluation.

7. Which of the following sections is re- D. A discussion of benefit and risk considerations.
quired in a PMA?
See 21 CFR 814.20(b)(3)(vi).
A. Patent certification information.
B. A copy of quality manual.
C. An economic cost/benefit assess-
ment.
D. A discussion of benefit and risk
considerations.




, 2009 RAC Practice Exam
Study online at https://quizlet.com/_1es8x3

8. Subacute toxicity testing should be B. In one rodent and one non-rodent species.
performed:
See ICH guideline M3 Maintenance of The ICH
A. In two rodent species. Guideline on Non-Clinical Safety Studies for The
B. In one rodent and one non-rodent Conduct of Human Clinical Trials for Pharmaceuti-
species. cals.
C. For a minimum of two weeks.
D. For a minimum of six months.

9. What FDA clearances are required to C. No clearance required.
export a drug approved by FDA?
There are no FDA export requirements for ap-
A. Certificate of Free Sale. proved products.
B. Customs Tax Stamps.
C. No clearance required.
D. FDA receipt for sample Form-484.

10. Fully quality-assured individual toxi- B. 120 days.
cology reports are not required for
submission of an initial IND applica- See FDA "Guidance for Industry Q & A: Content and
tion. However, finalized and fully qual- Format of INDs for Phase 1 Studies of Drugs, In-
ity assured reports should be avail- cluding Well-Characterized, Therapeutic, Biotech-
able to FDA upon request within what nology-Derived Products." October 2000.
period of the start of the human
study?

A. 90 days.
B. 120 days.
C. One year.
D. The final report is only required in
the submission for the NDA.

Document information

Uploaded on
June 15, 2025
Number of pages
45
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$21.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TutorGemini
5.0
(502)
Sold
6952
Followers
2
Items
3069
Last sold
4 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions