• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 3 out of 22 pages
Exam (elaborations)

NICET Level 1 Water Based Systems Layout NFPA13 Comprehensive Questions (Frequently Tested) with Verified Answers

Document preview thumbnail
Preview 3 out of 22 pages

NICET Level 1 Water Based Systems Layout NFPA13 Comprehensive Questions (Frequently Tested) with Verified Answers

Content preview

NICET Level 1 Water Based
Systems Layout NFPA13
Comprehensive Questions
(Frequently Tested) with
Verified Answers
The document that provides the designer with information about the intended use of the building -
Answer: Owner's certificate NFPA 13-4.2



A K-8.0 sprinkler has _________ of the nominal discharge of a K-5.6 sprinkler - Answer: 140% NFPA 13-
Table 7.2.2.1



Where the design is based on the density/area method, the design area shall be a rectangular area
having a dimension parallel to the branch lines at least _____ times the square root of the sprinkler
operation. - Answer: 1.2 NFPA 13-28.2.4.2.1



An intermediate level between the floor and ceiling of a level would be considered a ____ - Answer:
Mezzanine IBC-Section 202 Definitions



Which of the following shall be included with water supply capacity information - Answer: Flow location,
residual pressure. NFPA 13-4.5.1



What NFPA standard refers to the Standard for the Installation of Standpipe and Hose Systems - Answer:
14 NFPA 13-ch.2



The stock of a spare sprinklers for a protection facility having 400 sprinklers shall be no less than ____ -
Answer: 12 NFPA 13-16.2.7.5



What type of pipe or tubing would have the least amount of friction loss - Answer: Plastic NFPA 13-Table
28.2.4.8.1

,What class of standpipe is intended for use by trained personnel - Answer: Class II NFPA 14-3.3.22.2



All of the following materials shall be classified as group C except_____

Polystyrene

Melamine

Fluoroplastics

Phenolic - Answer: Polystyrene NFPA 13-20.4.7



Occupancies where the quantity and combustibility of contents are very high, and dust, lint or other
materials are present, introducing the probability of rapidly developing fires with high rates of heat
release but with little or no combustible or flammable liquids are classified as ___ - Answer: Extra hazard
(Group 2) NFPA 13-3.3.141.1



All threaded pipe and fittings shall have threads cut to which standard - Answer: ASME B1.20.1 NFPA 13-
7.4.1



Consider the hydrant shown. What coefficient would be used to calculate the discharge (Q) during flow
testing. (outlet smooth and rounded - Answer: .9 NFPA 291 - Figure 4.9.1



What is the device shown in the image below - Answer: Pitot Gauge - Equipment



NFPA 13 requires a single air vent to be provided on wet pipe systems utilizing metallic pipe. What is the
purpose of the air vent? - Answer: Reduce corrosion activity NFPA 13-A.16.7



You are using a power tool that has a 3-prong (grounded) plug. Unfortunately, the only outlets available
are 2 prong (non grounded) What action is required? - Answer: Locate a 3-prong plug or use a tool with
a 2-prong plug - Osha



The maximum floor area of the hydraulically calculated extra hazard classification system that can be
supported from one sprinkler riser is____? - Answer: 40,000 sf. NFPA 13-4.4.1(3)



A ceiling with a slope of 2 in 12 would be considered - Answer: Horizontal NFPA 13-3.3.28.2

, 1.

What is the item pictured here? item that is a horse shoe shape with a beveled top piece and hole in
the center of the top piece - Answer: Clevis Hanger NFPA 13-A.17.1



The NFPA 13 standard applies to which of the following?

FACP's

Fittings

Piping

Halon

Valves

Selection of sprinklers

Dialers - Answer: Fittings

Piping

Valves

Selection of sprinklers

NFPA 13-1.3.1



Sprinklers should only be painted by the manufacturer - Answer: True NFPA 13-7.2.5.2



When a single main less than _____ diameter serves both domestic and fire systems, the domestic
demand shall be added to the hydraulic calculations for the fire system at the point of connection unless
provisions have been made to isolate domestic demand - Answer: 4" NFPA 13-5.1.3.3



Paddle-type waterflow alarm indicators shall be installed in which of the following systems only -
Answer: Wet systems NFPA 13-16.11.3.4



What is not considered a residential occupancy per NFPA 13R - Answer: Single family dwelling NFPA
13R-3.3.10

Document information

Uploaded on
June 10, 2025
Number of pages
22
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$15.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
YourExamplug
4.1
(74)
Sold
223
Followers
27
Items
18055
Last sold
6 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions