According to ASTM C1064, what is one reason to take the temperature of concrete? - CORRECT ANSWER-to verify conformance to a specific requirement. A max. temp. of freshly mixed concrete is specified in ASTM C1064. T/F - CORRECT ANSWER-False The sample of concrete used for temperature determination must be rodded 25 times. - CORRECT ANSWER-False Sampling by this method covers procedures or obtaining representative samples, on which test are to be performed to determined __ with quality requirements of the specifications under which the concrete is furnished. - CORRECT ANSWERCompliance This method covers sampling from four types of mixers, which are __, __, __, and __. - CORRECT ANSWER-Stationary mixers / Paving mixers / revolving drum mixers / open top mixers The elapsed time between obtaining the first and final portions of a composite sample shall not exceed __ min. - CORRECT ANSWER-15 min. Portions of a composite sample shall be thoroughly mixed before beginning test on the sample. T/F - CORRECT ANSWER-True Start tests for slump, temp, and air content within __ min. after obtaining the final portion of the composite sample. - CORRECT ANSWER-5 min. The end of the temperature sensing portion of the temperature measuring device is submerged a minimum of __mm [__in.] into the freshly mixed concrete. - CORRECT ANSWER-77mm /3in. The temperature measuring device shall be capable of accurately measuring the temperature of freshly mixed concrete to +- __C [+__F] throught a range of __. - CORRECT ANSWER-0.5 C / +-1F / 0-50 Decrees C

Content preview

ACI Concrete Field Testing Technician -
Grade I

According to ASTM C1064, what is one reason to take the temperature of concrete? -
CORRECT ANSWER-to verify conformance to a specific requirement.

A max. temp. of freshly mixed concrete is specified in ASTM C1064. T/F - CORRECT
ANSWER-False

The sample of concrete used for temperature determination must be rodded 25 times. -
CORRECT ANSWER-False

Sampling by this method covers procedures or obtaining representative samples, on
which test are to be performed to determined __ with quality requirements of the
specifications under which the concrete is furnished. - CORRECT ANSWER-
Compliance

This method covers sampling from four types of mixers, which are __, __, __, and __. -
CORRECT ANSWER-Stationary mixers / Paving mixers / revolving drum mixers / open
top mixers

The elapsed time between obtaining the first and final portions of a composite sample
shall not exceed __ min. - CORRECT ANSWER-15 min.

Portions of a composite sample shall be thoroughly mixed before beginning test on the
sample. T/F - CORRECT ANSWER-True

Start tests for slump, temp, and air content within __ min. after obtaining the final portion
of the composite sample. - CORRECT ANSWER-5 min.

The end of the temperature sensing portion of the temperature measuring device is
submerged a minimum of __mm [__in.] into the freshly mixed concrete. - CORRECT
ANSWER-77mm /3in.

The temperature measuring device shall be capable of accurately measuring the
temperature of freshly mixed concrete to +- __C [+__F] throught a range of __. -
CORRECT ANSWER-0.5 C / +-1F / 0-50 Decrees C

The temp. measuring device shall be verified __, or whenever there is a question of __.
- CORRECT ANSWER-Annually / accuracy

, The temp of concrete may be measured in a wheelbarrow? T/F - CORRECT ANSWER-
True

The temp. of concrete may be measured in a wall form. T/F - CORRECT ANSWER-
True

A composite sample of concrete is required even if the only purpose for obtaining the
sample is to determine temp. T/F - CORRECT ANSWER-False

What must be done to the sample container prior to sampling the concrete - CORRECT
ANSWER-It must be dampened with water

What must be done to the concrete surrounding the temp measuring device after the
device is submerged in the fresh concrete? - CORRECT ANSWER-Gently press the
concrete at the surface around the measuring device.

How long must the temperature measuring device remain in the freshly mixed concrete?
- CORRECT ANSWER-At least 2 min., no longer than 5 min.

After the temperature of the concrete is read, what is then required? - CORRECT
ANSWER-Reporting of temp.

The temp. of concrete is reported to the nearest __. - CORRECT ANSWER-1 degree F


start molding specimens fr strength tests within __ after fabrication the composite
sample. - CORRECT ANSWER-15 min.

The concrete sample must be protected from contamination and __. - CORRECT
ANSWER-Rapid evaporation

The maximum size sample for making strength test specimens is __ ft cubed -
CORRECT ANSWER-1 foot cubed.

When sampling from a STATIONARY mixer, the batch must be sampled at __ or more
regularly spaced intervals during discharge of the middle portion of the batch. -
CORRECT ANSWER-2

When sampling from a PAVING mixer, obtain samples from at least __ different portions
of the pile and combine them into one composite sample for test purposes - CORRECT
ANSWER-5

When sampling from a REVOLVING DRUM TRUCK mixer, sample the concrete by
collecting __ or more portions taken at regularly spaced intervals during discharge of
the middle portion of the batch. - CORRECT ANSWER-2

Document information

Uploaded on
June 10, 2025
Number of pages
5
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$10.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ACADEMICMATERIALS
4.0
(101)
Sold
629
Followers
185
Items
10510
Last sold
16 hours ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions