) Portable Fire Extinguishers are required to checked by a W-96
certificate of fitness holder when?
a) Monthly
b) Weekly
c) Every 5 years
d) Annually Ans✓✓✓ D. Annually
A Fire Alarm Control Panel (FACP) initiates following signals EXCEPT:
A. Fire Alarm Signals
B. Supervisory Signals
C. Trouble Signals
D. National Disasters Ans✓✓✓ D. National Disasters
A Fire Guard must, after initial 4 hours of an out of service condition do
what?
A. Have a F-01 Certificate of Fitness
B. be maintained continuously for 24 hours a day
C. patrol all areas at least once an hour
D. ALL of the ABOVE Ans✓✓✓ D. ALL of the ABOVE
Adequate aisle space shall be maintained throughout the emergency
shelter. Aisles shall not be less than?
,A. 36 inches in width, except that cross aisles (aisle space in the main
hallways) shall not be less than 48 inches in width
B. All aisle must at least 48 inches wide
C. All aisle must be 36 inches wide
D. Aisle width depends on the building layout. Ans✓✓✓ A. 36 inches in
width, except that cross aisles (aisle space in the main hallways) shall
not be less than 48 inches in width
All elevators equipped with Phase I emergency elevator recall and
Phase II emergency in-service elevator operation shall be maintained in
proper working order such that the emergency elevator operations are
operable at all times. All elevators shall be subjected, at least a
_______, to a Phase I recall test. All elevators shall also be subjected, at
least a ________, to a minimum of a Phase II one-floor operation test.
A. Monthly, Monthly
B. Weekly, Weekly
C. Semi Annually, Annual
D. Monthly, Semi Annually Ans✓✓✓ A. Monthly, Monthly
All newly installed fire alarm pull stations must be located within how
many feet of the exit doorway opening?
A. 1
B. 2
C. 3
D. 5 Ans✓✓✓ D.5
, All of the following are Building Fire protection features that are
normally activated by the fire alarm system except:
a) Fire Dampers close
b) Elevator recall
c) HVAC shutdown
d) All Call communication activation Ans✓✓✓ D. All call
communication activation
Are Individuals who are certified for the F-80 Certificate of Fitness will
be exempt from having to obtain a separate S-95 Certificate of Fitness
for Supervision of Fire Alarm Systems and Other Related Systems.
A. Yes they are always exempt from needing an S-95
B. No they need to have and S-95 at all times.
C. Yes as long as someone in the building has a valid S-95
D. Yes exemption is for Coordinator of Fire Safety & Alarm Systems in
Homeless Shelters who work in shelters only. Ans✓✓✓ D. Yes
exemption is for Coordinator of Fire Safety & Alarm Systems in
Homeless Shelters who work in shelters only.
Carbon Monoxide Detectors are required in any building that has:
A. A theater
B. A lounge
C. Fossil (gas / oil ) fuel burning equipment