FDNY Fire Life & Safety Director Test #1 | Questions and Correct Solutions Latest Update2025/2026
FDNY Fire Life & Safety Director Test #1 | Questions and Correct Solutions Latest Update A supply of at least six spare sprinkler heads must be kept available on the premises near what location? Main control valve Wet and dry chemical fire extinguishing systems must be visually inspected at least _________.(Refer to the Reference material) monthly In the event of an activation of fire alarm, the FLS Director must immediately report to_______. The Fire Command Center The majority of deaths due to a smoke or fire situation are a result of: Smoke inhalation and oxygen deficient fire gases If the fourth floor is "off-line" with the central station due to welding and cutting, and during the course of the day, an initiating device is activated on the eleventh floor, what action should the Fire Life Safety Director take? Immediately notify the Fire Department and request a response. If you are looking at a stairway door and notice a number on the door, which of the following is TRUE? You're on the stair side of a door. Which comes first when operating a portable fire extinguisher: Pull the pin When ordinary combustible materials like wood, cloth, paper, rubber, or even some plastics, are used to fuel a fire, it would be deemed as a _________ fire. Class A As a general practice, during a fire, occupants in non-affected areas may be safest if they __________. Remain in place at their present location and listen for announcementsThe water flow alarms of a standpipe system must be tested ____________. (Refer to the Reference material) Quarterly What would be described as a continuous and unobstructed path of vertical and horizontal egress travel form any occupied portion of a building, structure or premises to a public way, consisting of the exit access, the exit, and the exit discharge: Means of egress The fire alarm system on the 15th floor is unable to function in compliance with the building code. In this case, the FLS Director should promptly notify: The tenants occupying the 15th floor Portable fueled equipment must be stored outdoors, unless it is stored in an FDNY approved indoor storage area. If not, which of the following cannot be used indoors? - Weed trimmers and lawn movers - Portable generators and power washers - Snow blowers What color tag would be placed at the main control valve to indicate that a fire protection system has been restored back to normal service? The system is fully operational and free of any defects. Green Fire Life Safety Directors are required to provide a refresher staff training session in an R-1 occupancy how often? 1 hour quarterly
Written for
- Institution
- FDNY Fire Life & Safety Director
- Course
- FDNY Fire Life & Safety Director
Document information
- Uploaded on
- May 27, 2025
- Number of pages
- 3
- Written in
- 2024/2025
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
fdny fire life safety director test 1 2025
Also available in package deal