Water must be degassed each time the ultrasonic cleaner's tank is changed, because correct
answers Excess bubbles from filling reduce the energy of the cavitation process
Mechanical washers and washer-decontaminators are regulated by the CDC. correct answers
false
Inventory replenishment system in which items removed from inventory are automatically
identified and tracked. when reorder point is reached, item information is generated on a
supply pack list in central storeroom. items are then issued, and transferred to appropriate
user are correct answers Automated Supply Replenishment System
When liquid chemicals are labeled as both a high-level disinfectant and a sterilant, the time
required to achieve sterilization is no longer than the time required to achieve high-level
disinfection. correct answers True
Which of the following means "around or about'? correct answers Peri
Typically 1 min of drying time programmed into flash cycles--removes steam from chamber
but doesn't dry device completely correct answers Drying Phase of Steam Sterilization
Why is important to evenly distribute large instruments i a set? correct answers Extra
condensation will make the set more difficult to dry
Dental Drills are used to remove cement. correct answers False
Surgery that removes lymph tissue in the pharynx (throat) correct answers tonsillectomy
Water softeners are used to remove BLANK in the water correct answers Calcium and
magnesium
The most efficient type of dry heat sterilizer is correct answers the mechanical convection
sterilizer
Disposable components such as pads and tubing on patient care equipment should be: correct
answers Discarded at point of use
To prevent coagulation of proteins, water temperature should be: correct answers Below
43°C (110°F)
Proposed standards are submitted from members such as AAMI. correct answers ANSI
What is burning in a class C fire? correct answers Energized Electric Equipment
Official inventory: correct answers Can be counted as an asset on the facilities balance sheet
Minimum Recommendations for EtO Aeration correct answers 8 hours at 140 F or 12 hours
at 122 F