KENTUCKY UST EVALUATION EXAM 2025/2026
QUESTIONS WITH ANSWERS MARKED A+
✔✔vent piping connected to underground tanks... - ✔✔must have a discharge point
upward which is not less than 12 feet above adjacent ground or two feet above the roof
at the point of attachment if attached to a building

✔✔couplings and fittings used in the piping of a steel underground petroleum product
storage system should be at least... - ✔✔150 pound malleable iron

✔✔between all underground lines and the excavation sides top and floor there should
be - ✔✔a minimum of 6 inches of well compacted approved backfill material

✔✔underground product lines and Vapor return lines if required for petroleum storage
systems should - ✔✔have a uniform slope of not less then 1/8 inch per foot toward the
tank

✔✔Flex joints should be installed on metallic underground petroleum system piping... -
✔✔a point where the piping connects with the underground tanks and where it ends at
pump Islands and vent risers

✔✔suction and fill lines should be installed - ✔✔at least 4 inches from the tank bottom

✔✔and air pressure tightness test conducted on a newly installed product piping system
before the system is covered or placed in use should? - ✔✔be conducted by
pressurizing the piping system at 50 PSIG for a period of one hour soaping all joints and
inspecting for bubbles

✔✔to minimize possible problems resulting from cracked fittings or sand holes and
fittings as well as corrosion of fittings it is recommended that? - ✔✔all metal fittings
used in piping systems be of extra-heavy quality

✔✔all the new piping should be tested with air pressure if for some reason typing has
been backfilled or has contained product prior to testing then a hydrostatic test should
be conducted. the proper pressure for a hydrostatic test of piping is? - ✔✔110% of
operating pressure but not less than 50 PSIG

✔✔before being covered new piping except for the fill pipe should be subjected to an air
test for a period of no less than - ✔✔1 hour

✔✔when preparing a new piping system for an air test you should first isolate the
product lines from? - ✔✔both tanks and dispensers

, ✔✔it is recommended that the installer provide a convenient means of venting Vapors
trapped and man weighs or at the end of sloped tanks for what purpose? - ✔✔to
facilitate tank tightness test at a later date

✔✔according to NFPA 30A dispensers and stalled in conjunction with remote pumping
systems should have a listed emergency shut-off valve installed with a? - ✔✔rigid
mount to the concrete Island

✔✔according to NFPA 30A if a vapor return pipe is located inside the dispenser housing
it must be equipped with a? - ✔✔Shear section or flexible connector

✔✔metallic tanks and piping in an underground storage system protected by a galvanic
cathodic protection system should? - ✔✔be electronically isolated from other
unprotected steel structures

✔✔when an impressed current cathodic protection system is used to protect an entire
underground tank system including tanks piping and Associated equipment what is
unnecessary? - ✔✔electrical isolation of storage system components is unnecessary
and in fact undesirable

✔✔prior to backfilling sacrificial anodes should? - ✔✔have any waterproof packaging
materials removed

✔✔when you are installing cathodically protected underground systems you should
make sure that anode lead wires and monitoring wires are? - ✔✔back filled with care
and left slack to provide flexibility

✔✔when sacrificial anodes are installed they should be? - ✔✔back filled with native soil
soaked with three to five gallons of water

✔✔connections between anode lead wires and structures that are to be thought of you
protected should be - ✔✔thermite welded or made by means of pressure type
grounding clamps

✔✔in the absence of specific plan installation of anodes used for the cathodic protection
of underground piping systems should be characterized by one of the following
Arrangements - ✔✔at least two magnesium anodes should be positioned vertically 5
feet from the center of the pipe trench and below the level of the piping

✔✔cathodic protected piping must be electronically continuous. unconnected pipe in the
system should be bonded with? - ✔✔number 12 TW or THHN stranded or solid wire

Document information

Uploaded on
May 22, 2025
Number of pages
14
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$12.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
BOARDWALKer
3.4
(20)
Sold
164
Followers
6
Items
26749
Last sold
3 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions