A) the technician certification is grandfathered for six months to allow time for taking the recertification exam. B) a new certification test must be taken within 90 days to be recertified. C) a new certification test must be taken within 90 days to be recertified. D) it is the technician's responsibility to comply with any future changes in the law. Answer: D correct answers If the EPA regulations should change after a technician becomes certified: A) hydrozine gas. B) helium gas. C) phosgene gas. D) all of the above will be formed. Answer: C correct answers At high temperatures, (i.e., open flames, glowing metal surfaces, etc.) R-12 and R-22 can decompose to form: A) R-123 B) R-24 C) R-141a/141b blend D) R-134a Answer: D correct answers Which of the following refrigerants is most commonly used as a replacement for R-12 in new household refrigerators? A) May 15, 1993. B) June 15, 1992.

Content preview

EPA Section 608 Type I || 100% verified solutions.

A) the technician certification is grandfathered for six months to allow time for taking the
recertification exam.
B) a new certification test must be taken within 90 days to be recertified.
C) a new certification test must be taken within 90 days to be recertified.
D) it is the technician's responsibility to comply with any future changes in the law.


Answer: D correct answers If the EPA regulations should change after a technician becomes
certified:


A) hydrozine gas.
B) helium gas.
C) phosgene gas.
D) all of the above will be formed.
Answer: C correct answers At high temperatures, (i.e., open flames, glowing metal surfaces, etc.)
R-12 and R-22 can decompose to form:


A) R-123
B) R-24
C) R-141a/141b blend
D) R-134a


Answer: D correct answers Which of the following refrigerants is most commonly used as a
replacement for R-12 in new household refrigerators?


A) May 15, 1993.
B) June 15, 1992.

,C) July 15, 1993.
D) November 15, 1993.


Answer: D correct answers Recovery equipment used for the service or repair of small
appliances must be certified by an EPA- approved laboratory if the recovery
equipment was manufactured after:


A) 4 pounds
B) 5 pounds
C) 7 pounds
D) 10 pounds


Answer: B correct answers What is the maximum allowable factory charge of refrigerant for
Type I appliances?


A) The pressure reading along with a temperature reading can indicate if there is excessive air or
other non-condensables in the cylinder.
B) The pressure reading can indicate the remaining cylinder capacity.
C) The pressure reading can indicate if the refrigerant has been damaged.
D) both "a" and "c".


Answer: A correct answers Why is it important to obtain an accurate pressure reading of
refrigerant inside a recovery cylinder?


A) recovering 90% of the refrigerant when the compressor is operating or achieving a 4 inch
vacuum under the conditions of ARI 740-1993.
B) recovering 80% of the refrigerant when the compressor is operating.
C) recovering 95% of the refrigerant when the compressor is operating or achieving a 4 inch
vacuum under the conditions of ARI740-1993.

, D) recovering 85% of the refrigerant when the compressor is operating.


Answer: A correct answers Recovery devices that were manufactured after November 15, 1993
and are used for recovery of refrigerant from small appliances must be
capable of:


A) they are too expensive to remain on every product.
B) they tend to leak over time.
C) they become loose and vibrate.
D) both "a" and "c"


Answer: B correct answers Solderless piercing valves should not remain installed on
refrigeration systems after completion of repairs because:


A) only nitrogen vapor should be used.
B) only liquid nitrogen should be used.
C) either liquid or vapor nitrogen can be used.
D) nitrogen can only be used if mixed with R-22.


Answer: A correct answers When ever nitrogen is used to pressurize or blow debris out of the
system:


A) a closed recovery tank inlet valve.
B) excessive air or other non-condensables in the recovery tank.
C) a closed recovery tank outlet valve.
D) Either choice "A" or "B"

Document information

Uploaded on
May 18, 2025
Number of pages
21
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$14.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
SirAnton
3.7
(118)
Sold
793
Followers
438
Items
40096
Last sold
4 hours ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions