CFESA Electrical

What do the following prefixes mean? Micro, Kilo,Mega,Milli - answer1/1,000,000, 1000,
1,000,000, 1/1000

If you know the wattage and voltage, how do you determine the current? - answer
Divide the wattage by the voltage

If you know the voltage and current how do you determine the wattage? - answer
Multiply voltage times current

If a circuit is supplied with 100 volts and the total resistance of the circuit is 200 ohms,
how much current will the circuit draw? - answer.5 amps

If a piece of equipment is supplied 208 volts and the amp meter clamped to the hot line
reads 20 amps, what is the wattage of the load? - answer4160 Watts

How much voltage is in one hot line? - answerNone

What happens to current in a parallel circuit? - answerIt divides across resistances

what happens to voltage across the loads in a parallel circuit? - answerstays the same

what happens to the voltage across the loads in a series circuit? - answerit divides
across the resistances

what happens to the current in a series circuit? - answerIt stays the same everywhere

in a parallel circuit the total resistance of the circuit will always be less than what
resistance? - answerthe smallest resistance

how do you find the total resistance of a series circuit? - answeradd the resistances
together

how do you find the total resistance of a parallel circuit? - answer1/RT = 1/R1 + 1/R2 +
1/R3 ...

If a circuit is wired parallel, and the supply voltage is 120 volts, each load must be rated
at what voltage? - answer120 volts

if a circuit has two elements wired in series, and each is rated at 120 volts, what voltage
must be supplied to the circuit in order for the elements to heat at full power? -
answer240 volts

,What is the advantage of using higher voltages? - answerLower Current and wire size

Is there a negative and positive line in AC power supplies? - answerNo

What is the voltage between two hot lines in a 230-volt system? - answer230V

What is the voltage between two hot lines in a 208-volt system? - answer208V

What is the voltage between a hot line and a neutral in a 230-volt single phase supply? -
answer115V

What is the voltage between a hot line and a neutral in a 208-volt single phase supply? -
answer120V

What is the accepted maximum voltage difference between the name plate voltage and
the supplied voltage? - answer+ or - 10%

What is the voltage between any two hot lines of a 230 volt delta power supply? -
answer230V

what is the voltage between a hot line and ground on a 240 volt delta power supply -
answerNo usable voltage

what is the voltage between any two hot lines of a 230 volt grounded delta power supply
- answer230V

draw a diagram of a 230 volt grounded delta power supply. label all of the voltages and
the wild leg - answer

what is the wild leg? - answerleg with higher than 120v to ground or neutral

what danger is the wild leg? - answerhigh voltage that will damage 120v component in
the circuit

what is the voltage between either of the non wild leg hot lines and neutral in a 230 volt
grounded delta system? - answer115v

how do you determine which hot line is the wild leg in a 250 volt grounded delta power
supply? - answerthe one that does not measure 120 volts to neutral or ground

what danger is there when replacing a three phase circuit breaker in a 230 volt
grounded delta power supply? - answercrossing the hot lines and supplying the wild leg
to the wrong terminal in the unit.

,Why is a "WYE" power supply so versatile - answercan get 120v and 208v as well as
single and three phase

What is the voltage between any two hot lines in a 208 volt WYE power supply? -
answer208v

What is the voltage between any hot line and neutral or ground in a 208 volt WYE
power supply? - answer120v

What is the voltage from any hot line to ground or neutral, on a 480 volt WYE power
supply? - answer277v

if you had a commercial building and you had a three phase supply to your building how
many different incoming power supplies would you need if the incoming three phase
supply was three phase delta? - answer2

if you had a commercial building and you had a three phase supply to your building,
how many different incoming power supplies would you need if the incoming three
phase supply was three phase grounded delta? - answer1

if you had a commercial building and you had a three phase supply to your building how
many different incoming power supplies would you need if the incoming three phase
supply was three phase WYE 208v? - answer1

approximately how much will the wattage increase on a 208v piece of equipment if it is
connected to 240v supply? - answer33%

approximately how much will the rated wattage decrease if a 240v unit is connected to a
208v power supply? - answer25%

what damage could potentially be caused to the supply wiring if 208v unit is connected
to a 240v supply? - answerhigher wattage created will damage heaters or other
components

how can the cooking characteristics of equipment be changed by a low supply voltage?
- answerslow recovery time, uneven cooking

when is the most opportune time to discover a low or high voltage problem? - answerat
equipment startup, before the unit is energized

can high voltage result in and overheating problem when trying to control the temp of an
oven? - answeryes

how many resistances must you have to have a balanced load? - answer3 or a multiple
of 3

, what is the formula for calculating the current draw from the wattage and voltage on a
three phase balanced load? - answeramperage = wattage / (voltage X 1.732)

how can you tell if a piece of equipment will be a balanced load or not? - answermust
have 3 or a multiple of three loads

Joe says a convection oven that has three heating elements, and a single phase blower
motor is a balanced three phase load. Jim says it is not. Who is right? - answerJim, sing
phase motor unbalances the load

Electricity will always follow what path? - answerPath of least resistance

Why should all equipment be grounded? - answersafety and code

How should the earth ground from the main fuse or breaker panel be connected? -
answerfrom grounding bus bar to ground rod or metal water pipe

in order for a receptacle to be properly grounded, the ground wire must run to where? -
answerall the way back to the panel

How much resistance should you read from a neutral connection to a ground
connection? - answer0 ohms

What is the difference between neutral and ground? - answerthe neatural normall
carries current, the ground does not

Can you get shocked from the casing on a piece of equipment if it is properly grounded?
- answerNo

Ground wires must always be what colors? - answergreen, green with yellow tracer, or
bare white

How much current does a short circuit draw? - answerInfinite Amps

if a cord on a unit is shorted, can it damage the power switch on the piece of
equipment? - answerNo

if a heating element on an electric grill is shorted could it damage the thermostat? -
answerYes

If a power switch is shorted on a heat lamp could it damage the heating element? -
answerNo

When checking voltage, you must touch your meter leads where? - answerAcross the
load you are measuring

Document information

Uploaded on
May 14, 2025
Number of pages
35
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$13.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
julianah420
4.2
(158)
Sold
715
Followers
328
Items
35986
Last sold
2 weeks ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions