In a preaction sprinkler system, what must happen before water
will flow? Select one:
A. The alarm condition must persist for a set time
B. An alarm initiating device must be activated
C. The dry-pipe valve must close
D.System water pressure must drop ( correct answers ) B. An
alarm initiating device must be activated

Where is a main sprinkler system valve usually
installed? Select one:
A. On the main riser, below the water supply
control valve
B. Outside the building, coming up out of the
ground on a post D.
C. Near the FDC On
D.On the main riser, above the water supply control valve
( correct
Which answers
class ) the main
of standpipe riser, above
is intended thedepartment
for fire water supply control
valve
use only? Select one:
A. III
B. II
C. I
D. IV ( correct answers ) C. I

Which is a distinguishing feature of old-style sprinkler
heads? Select one:
A. All heads are of the pendant type
B. Only a few activation temperatures are available
C. The heads are highly sensitive to pressure
fluctuation ( correct answers )
D.The discharge pattern directs some water onto D.
the ceiling The discharge pattern directs some water
onto the
Which ceiling
is a function of a sprinkler
head? Select one:
A. Detect smoke or fumes
B. Activate the fire alarm system
C. Report any trouble in the
system
D.Auto-restore when the fire is out ( correct answers ) B.
Activate the fire alarm system



GRADED
A+

,Which is a typical temperature rating for a sprinkler head in a light-hazard
occupancy such as an office building?
Select one:
A. 225°F (107°C)
B. 205°F (96°C)
C. 185°F (85°C)
D. 165°F (74°C) ( correct answers ) D. 165°F (74°C)

Which is the preferred water source for a sprinkler
system? Select one:
E. An elevated storage tank
F. A private fire protection supply system
G. A municipal water system
H. A dedicated static supply ( correct answers )
C. A municipal water system

Which sprinkler head mechanism uses a liquid-filled glass capsule to hold
the cap in place?
Select one:
I. Liquid capsule
J. Frangible bulb
K. Chemical pellet
L. Fusible device ( correct answers ) B. Frangible bulb

Which type of facility monitors alarms systems located at multiple
facilities? Select one:
M.Protected premises control center
N. Central station
O. Remote alarm receiving center
P. Supervising alarm center ( correct answers ) B. Central
station

Which type of fire alarm annunciation system identifies the zone in which
the alarm was initiated audible or visual signals?
Select one:
Q. Individual
R. Addressable
S. Coded
T. Master ( correct answers ) C. Coded

A fire department pumper can supplement a sprinkler system water supply
through the: Select one:
U. Class I standpipe.
V. APV.
W.FDC.
X. OS&Y. ( correct answers ) C. FDC.


GRADED
A+

, According to NFPA 72, which type of alarm is caused by improper
installation of an alarm system?
Select one:
A. Trouble
B. Nuisance
C. False
D. Unwanted ( correct answers ) B. Nuisance

According to NFPA 72, which type of alarm occurs when an activation of a
fire alarm is not the result of a potentially hazardous condition?
Select one:
E. Trouble
F. Tamper
G. False
H. Nuisance ( correct answers ) D. Nuisance

According to the NFPA, a smoke alarm should be replaced after years
from the date of manufacture
Select one:
I. 3
J. 7
K. 5
L. 10 ( correct answers ) D. 10

All of the following are standard sprinkler head mounting positions except
one. Choose the exception.
Select one:
M.Sidewall
N. Branch
O. Pendent
P. Upright ( correct answers ) B. Branch

Closing the valve is a method of shutting down the flow of
water in a sprinkler system.
Select one:
Q. alarm
R. post indicator
S. main check
T. main water service ( correct answers ) B. post indicator

Fire alarm systems in most high-rise buildings are programmed to alert the
occupants located:
Select one:
U. on the alarm floor and floors immediately below and above the alarm
floor.
V. on the alarm floor and floor immediately above the alarm floor.
W.throughout the entire building.

GRADED
A+

Document information

Uploaded on
May 12, 2025
Number of pages
30
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$18.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
HopeJewels
3.6
(8)
Sold
96
Followers
11
Items
8854
Last sold
4 days ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions