INTERNATIONAL RESIDENTIAL CODE
MECHANICAL CODE MASTER SET
EXAM QUESTIONS WITH CORRECT
ANSWERS
IMC/Residential

A domestic open-top broiler unit shall be provided with a minimum clearance of ______
between the hood and the underside of the combustible material or cabinets. -
ANSWER-1/4 inch
M1505.1

IMC/Residential

For a domestic open-top boiler unit, a minimum of ______ shall be maintained between
the cooking surface and combustible material or cabinet. - ANSWER-24 inches
M1505.1

IMC/Residential

Heating equipment connected to an above-ground duct system shall be designed to
limit discharge air temperature to a maximum of ______. - ANSWER-250* F
M1601.1.1 #1

IMC/Residential

When serving heating, cooling or ventilation equipment, above-ground factory-made
duct systems shall be constructed of materials classified as ______ . - ANSWER-Class
0 or Class 1
M1601.1.1 #2

IMC/Residential

A 16-inch exposed retangular duct that is a portion of an above-ground duct system
shall have a minimum equivalent galvanized sheet gage of ______ . - ANSWER-No. 26
Table M1601.1.1 (2)

IMC/Residential

Gypsum board may be used in the construction of a return air plenum in an above-
ground duct system, provided the maximum air temperature is ______ and the exposed
surfaces are not subject to condensation. - ANSWER-125* F

,M1601.1.1 #5

IMC/Residential

What is the maximum flame spread index permitted for materials used to construct
above-ground duct systems? - ANSWER-200
M1601.1.1 #6

IMC/Residential

Where used in an underground duct system, the maximum permitted duct temperature
for plastic ducts shall be ______ . - ANSWER-150* F

IMC/Residential

When protected by concrete, metal ducts installed in an underground duct system shall
be encased with a minimum thickness of ______ . - ANSWER-2 inches
M1601.1.2

IMC/Residential

Duct coverings and linings for factory-made ducts shall have a maximum flame spread
index of ______ and a maximum smake-developed index of ______ . - ANSWER-25,
50
M1601.3 #1

IMC/Residential

Factory-insulated flexible factory-made ducts shall be identified at a maximum intervals
of ______ with the name of the manufacturer, the thermal resistance R-value, the flame
spread index and the smoke-developed index. - ANSWER-3 feet
M1601.3 #3

IMC/Residential

Where vibration isolators are installed between mechanical equipment and metal ducts,
they shall have a maximum length of ______ . - ANSWER-10 inches
M1601.2.1

IMC/Residential

Where metal ducts are supported by 1/2 inch wide metal straps, the straps shall be
minimum ______ and located a maximum of ______ on center. - ANSWER-18-gage, 10
feet
M1601.4.3

, IMC/Residential

In an existing structure, an under-floor space used as a supply plenum shall be formed
by meterials having a maximum flame spread raiting of ______ . - ANSWER-200
M1601.5.2

IMC/Residential

Where the under-floor space is permitted to be used as a supply plenum, a duct shall
extend from the furnace supply outlet to a minimum of ______ inches below the
combustible framing. - ANSWER-6
M1601.5.3

IMC/Residential

Unless the discharge outlet is a minimum of ______ above the outside air inlet,outside
air for forced-air heating system shall be taken a minimum of ______ from an appliance
vent outlet, a vent opening from a plumbing drainage system, or the discharge outlet of
an exhaust fan. - ANSWER-3 feet, 10 feet
M1602.2 #1

IMC/Residential

Which one of the following spaces is acceptable as a source for return air for a forced-
air heating system?
sleeping room
bathroom
kitchen closet - ANSWER-sleeping room
M1602.2 #4

IMC/Residential

Outdoor air inlets for a return air system shall be covered with screens having a
minimum opening size of ______ and a maximum opening size of ______ . - ANSWER-
1/4 inch, 1/2 inch
M1602.3

IMC/Residential

Built-in or freestanding ranges shall have a minimum vertical clearance of ______
above the cooking top to an unprotected combustible construction. - ANSWER-30
inches
M1901.1

IMC/Residential

Document information

Uploaded on
May 11, 2025
Number of pages
21
Written in
2024/2025
Type
Exam (elaborations)
Contains
Unknown
$22.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
STUDYGUIDESET
3.2
(6)
Sold
48
Followers
17
Items
2528
Last sold
1 week ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions