Spiked Sample - is a wet wipe spiked with a known amount of lead to test the laboratories ability to analyze dust wipe samples Ratio for spiked samples - 1 sample for every 50 field samples Advantages of composite sampling - lower cost per surface sampled; increased surface area that can be wiped for the same cost; Disadvantages of composite sampling - information on specific location is lost; laboratories will have to adopt special handling and digestion procedures Composite samples should be collected from where? - bare floors, carpeted floors (wall to wall carpet), window sills, window troughs, exterior surfaces What happens if a composite sample fails? - all the rooms with that component must be re-cleaned When should single surface wipe samples be used? - when informion is needed to determine leaded dust levels in a specific location; in other areas where leaded dust levels are expected to be high to determine if targeted cleaning efforts are needed. When should composite wipe samples be used? - controlling cost is essential; no reason to suspect that dust levels from same surfaces in different rooms will vary greatly; costs of multiple-room cleanup will not greatly exceed cost of single room cleanup Determine numbers of post-abatement clearance samples to be collected? - depends upon the number of rooms treated, the type of sampling conducted, and whether work was done on interior or exterior When does the EPA not require dust wipe sampling? - following abatement exclusively on exterior of a dwelling What are EPA requirements for clearance sampling multifamily housing of 20 units or more - require that a sufficient number of residential dwellings are selected for dust sampling to provide a 95 percent level of confidence that no more than 5% or 50 of the residential dwellings in the randomly sampled population exceed the appropriate clearance levels

Content preview

EPA LEAD SUPERVISOR EXAM STUDY GUIDE
WITH ACTUAL QUESTIONS 2025

✅Spiked Sample - ✅✅is a wet wipe spiked with a known amount of lead to test the
laboratories ability to analyze dust wipe samples

✅Ratio for spiked samples - ✅✅1 sample for every 50 field samples

✅Advantages of composite sampling - ✅✅lower cost per surface sampled;
increased surface area that can be wiped for the same cost;

✅Disadvantages of composite sampling - ✅✅information on specific location is lost;
laboratories will have to adopt special handling and digestion procedures

✅Composite samples should be collected from where? - ✅✅bare floors, carpeted
floors (wall to wall carpet), window sills, window troughs, exterior surfaces

✅What happens if a composite sample fails? - ✅✅all the rooms with that component
must be re-cleaned

✅When should single surface wipe samples be used? - ✅✅when informion is
needed to determine leaded dust levels in a specific location; in other areas where
leaded dust levels are expected to be high to determine if targeted cleaning efforts are
needed.

✅When should composite wipe samples be used? - ✅✅controlling cost is essential;
no reason to suspect that dust levels from same surfaces in different rooms will vary
greatly; costs of multiple-room cleanup will not greatly exceed cost of single room
cleanup

✅Determine numbers of post-abatement clearance samples to be collected? -
✅✅depends upon the number of rooms treated, the type of sampling conducted, and
whether work was done on interior or exterior

✅When does the EPA not require dust wipe sampling? - ✅✅following abatement
exclusively on exterior of a dwelling

✅What are EPA requirements for clearance sampling multifamily housing of 20 units
or more - ✅✅require that a sufficient number of residential dwellings are selected for
dust sampling to provide a 95 percent level of confidence that no more than 5% or 50 of

,the residential dwellings in the randomly sampled population exceed the appropriate
clearance levels

✅Final dust wipe sample results must be reported in - ✅✅ug/ft2
✅Lead Paint 1978 level allowed - ✅✅.06%; 600 ppm

✅Current level lead allowed in paint - ✅✅.009%; 90 ppm

✅Lead Paint allowed in all other consumer products - ✅✅.01%; 100 ppm

✅Hazardous Waste Toxic Characteristic Leaching Procedure (TCLP) - ✅✅5 ppm

✅The use of lead based paint exceeding .06% was banned - ✅✅in 1978 for
residential housing.

✅T/F the concentration of lead paint in deteriorating housing must be greater than 1
mg/cm2 by XRF to pose a threat to workers doing renovation or abatement practices. -
✅✅False

✅Title X does not apply to; - ✅✅bridges and steel structure; hotels and motels
rented less than 100 days and commercial complexes.

✅What is the primary objective of a Lead Paint Risk Assessment? - ✅✅to discover
lead hazards

✅What is the primary objective of a Lead Paint Inspection? - ✅✅to discover lead
paint

✅TSCA Title IV, Section 402/404 Rule directed EPA to; - ✅✅develop training and
certification requirements for lead professionals. Individuals performing inspections and
risk assessments for lead hazards must be certified through the EPA accredited
program

✅T/F EPA's debris rule advises contractors that lead waste generated during
renovation and remodeling of residential housing is now waived from RCRA's rule and
can be disposed of as municipal waste - ✅✅True

✅T/F OSHA established the standard for the worker's permissible exposure limit,
action limit, and exposure time while abating lead - ✅✅True

✅T/F Section 1012/1013 within Title X are sections referring to HUD rules - ✅✅True

✅Y/N Are lead inspections mandatory in pre 1978 housing? - ✅✅No

, ✅A lead inspection is a - ✅✅surface by surface investigation for lead based paint.

✅Two most common ways for lead to enter the body? - ✅✅ingestion and inhalation

✅What body system is most affected by lead poisoning? - ✅✅the nervous system

✅Why are dust samples taken? - ✅✅to identify lead paint hazards; to see if the
contractor cleaned up properly after renovation; to identify a dust hazard from lead that
may not be paint

✅After a final clearance wipe down, a clearance test can begin _________ after the
clean-up. - ✅✅one hour

✅T/F No one should operate the XRF analyzer until they have received radiation
safety training - ✅✅True

✅What does a performance characteristic sheet for an XRF instrument determine? -
✅✅XRF specified range; results that are positive, negative, and inconclusive;
calibration check tolerances

✅A testing combination is a - ✅✅unique combination of room equivalents, building
component types, or substrates

✅An abbreviated test can be performed when - ✅✅the owner agrees; all
components tested are the same in each room equivalent; the component tested is
positive for lead based paint in the first five rooms tested.

✅T/F An XRF calibration check should be performed before an inspection begins; after
the inspection is completed, or at least every 24 hours, whichever occurs first. -
✅✅False

✅Dust wipe media must meet what criteria? - ✅✅ASTM E 1792 laboratory criteria

✅A soil sample from around the drip line of a house resulted in 530 ppm. As a risk
assessor you must explain to the owner what should be done with the soil. - ✅✅soil
where children have contact must be abated; interim controls can be used to eliminate
the present hazard.

✅What is the procedure for clean up of lead dust after abatement or renovation? -
✅✅HEPA vacuum, wet clean, HEPA vacuum again

✅What should a risk assessor do prior to conducting a risk assessment on a house? -
✅✅gather information on the property

Document information

Uploaded on
May 9, 2025
Number of pages
18
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$12.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TopGradeInsider
4.2
(13)
Sold
184
Followers
2
Items
58897
Last sold
1 day ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions