Steves Review Exam 3 Questions and
Answers 2025
StaticAboneAimagingAisAperformedAseveralAhoursAafterAtracerAadministrationAtoApermit
A.AMaximumAtracerAuptakeAinAtheAskeleton
B.ATracerAclearanceAfromAnormalAboneAtissue
C.ATracerAclearanceAfromAsitesAofAinfiltrationA
D.ABloodAclearanceAofAexcessAtracer
E.ATracerAclearanceAfromAtheAkidneysA-ACORRECTAANSWERSA-
D.ABloodAclearanceAofAexcessAtracer
MaximumAskeletalAuptakeAofA99mTcAMedronateAandA99mTcAOxidronateAoccursAwithinA45
minAafterAtracerAadministrationAandAimagingAisAtoAallowAtheAexcessAcirculatingAtracerAtoAbe
AclearedAfromAtheAbloodAbyAtheAkidneys.ASuchAcleaenceAisAnecesaryAtoAincreaseAtheAtarge
tA(bone)AnonAtargetA(softAtissue)AratioAforAanAoptimalAimage
ForAwhichAofAtheAfollowingAclinicalAindicationsAwouldAlimitedAboneAimagingA("spot"Aviews)A
beAmostAappropriateA
A.ARuleAoutAskeletalAmetastasesA
B.AEvaluateAPaget'sAdisease
C.AEvaluateAtemporomandibularAjointApain
D.AWithAhistoryAofAchidAabuse,AruleAoutAoccultAfractures
E.ARuleAoutAkidneyAstonesA-ACORRECTAANSWERSA-
C.AEvaluateATemporomandibularAjointApain
A,AB,ACAtendAtoAwidespreadAthroughoutAtheAskeletalAsystem.AForAtheseAaAtotalAboneAimagi
ngAisAindicated.AForATMJAimagingAspotAviewAimagingAofAtheAskullAfaceAandAcervicalAspineAi
sAindicated
ThreeAorAfourAphaseAboneAimagingAisAparticularlyAusefulAwhenAwhichAofAtheAfollowingAcon
ditionsAisAsuspected
A.AOsteomyelitisA
B.AOsteoporosisA
C.ASkeletalAMetastasesA
D.AStressAfractureA
E.ACompoundAfractureA-ACORRECTAANSWERSA-A.AOsteomyelitis
EarlyAimagesAareAimportantAinAdiagnosingAinflammatoryAconditionsAsuchAasAosteomyelitis.
ATheAflowAstudy,AtheAfirstAphaseAofAaAmultiphaseAboneAimageAisAimportantAinAdemonstratin
gAincreasedAbloodAflowAtoAtheAaffectedAarea.AInAosteomyelitisAtracerAconcentrationAremain
sAincreasedAthroughoutAtheAotherAphases
TheAstandardAviewsAperformedAinAaAlungAperfusionAstudyAare
A.AAnteriorAandAposteriorAonly
B.APosteriorAandAobliquesAonly
,C.AAnterior,AposteriorAandAlateralAofAtheAaffectedAlung
D.ALateralsAandAobliquesAonlyA
E.AAnterior,Aposterior,Alateral,AandAobliquesA-ACORRECTAANSWERSA-
E.AAnterior,APosterior,ALateral,AObliques
AtAleastA6AviewsAshouldAbeAperformedAinAaAlungAperfusionAstudyA(someArequireA8Aviews)
Anterior,Aposterior,ArightAandAleftAlaterals,ArightAandAleftAposteriorAobliques.ASometimesArig
htAandAleftAanteriorAobliques
UponAcompletionAofAanAimagingAprocedureAtheApatientAsitsAupAquicklyAandAcomplainsAofAdi
zzinessAandAfeelingAfaint.ATheAmostAappropriateAactionAforAtheAtechnologistAwouldAbeAto
A.AHaveAtheApatientAstandAandAwalkAaroundAtheAroomA
B.ACheckAvitalAsigns
C.AHaveAtheApatientAlieAdownAagain
D.ATalkAwithAtheApatientAandAhaveAtheApatientAbreatheAslowlyAandAdeeplyA
E.AAskAtheApatientAifAtheyAhaveAaAfamilyAhistoryAofAsyncopeA-ACORRECTAANSWERSA-
D.ATalkAwithApatientAandAhaveAtheApatientAbreatheAslowlyAandAdeeply
AllAofAtheAfollowingAstatementsAaboutAperformingAaAlungAventilationAstudyAwithA99mTcAPen
tetateAaerosolAareAtrueAexcept
A.AMultipleAprojectionsAmayAbeAobtainedAwithAoneAdoseAofAtracer
B.ATheApatientAisAdisconnectedAfromAtheAnebulizerAafterAinhalationAofAtheAaerosolA
C.ATheApatientAisAimagedAwhileAinhalingAparticlesAfromAtheAnebulizer
D.ATheAfaceAmask,AtubingAandAnebulizerAmustAbeAdisposedAofAasAradioactiveAwaste
E.ASomeAresidualAtracerAmayAbeApresentAinAtheAesophagusA-ACORRECTAANSWERSA-
C.ATheApatientAisAimagedAwhileAinhalingAparticlesAfromAtheAnebulizerA
ToAperformAaAventilationAstudyAwithA99mTcAPentetateAaerosolAtheAliquidAtracerAisAplacedAi
ntoAtheAnebulizerAwhereAitAisAbrokenAupAintoAsmallAairborneAparticlesAthatAareAinhaledAbyAth
eApatient.ATheApatientAisAconnectedAtoAtheAnebulizerAwithAtubingAandAaAfaceAmaskAorAmout
hpiece.AAfterAinhalationAofAtheAtracer,AtheApatientAisAdisconnectedAfromAapparatus.AThenAt
heApatientAisAimaged.ABecauseAtheAparticlesAremainAwhereAtheyAhaveAbeenAdepositedAforA
aAperiodAofAtime,AtheAsameAviewsAthatAareAacquiredAforAtheAperfusionAimagesAmayAbeAacq
uiredAforAtheAventilationAimages.ATheAnebulizer,AtubingAandAfaceAmaskAallAareAcontaminat
edAandAmustAbeAhandledAasAradioactiveAwaste
TheApurposeAofAwrappingAtheAlegsAwithAelasticAbandagesAbeforeAperformingAaAradionuclid
eAvenogramAwithA99mTcAMAAAisAto
A.ADistendAtheAveinsAinAtheAfeet
B.APreventAbloodAclotsAfromAtravelingAtoAtheAlung
C.ASuppressAsuperficialAcirculationA
D.ATrapAtheAtracerAonAtheAlowerAextremitiesA
E.AIncreaseAlowAbloodApressureAinAtheApatientA-ACORRECTAANSWERSA-
C.ASuppressAsuperficialAcirculation
A
TheApurposeAofAradionuclideAvenographyAisAtoAdemonstrateAtheApresenceAofAthrombiAinAth
eAdeepAveinsAofAtheAlegsAandApelvisA(internalAiliac).AThereforeAelasticAbandagesAareAusedAt
,oAwrapAtheAlegsAbetweenAtheAanklesAandAkneesAtoAdiverAbloodAflowAfromAtheAsuperficialAcir
culationAtoAtheAdeepAvenousAsystem
WhenAtheAradiationAlevelAcomingAfromAaAradioiodineAtherapyApatientAinAisolationAisAmeasu
red,AitAshouldAbeAmeasured
A.AEveryAday
B.AEveryAdayAatAtheAsameAtime
C.AAtAtheAsameAdistanceAfromAtheApatientAeachAtime
D.AEveryAdayAandAatAtheAsameAdistanceAfromAtheApatientAeachAtime
E.AAtAdifferentAdistancesAfromAtheApatientAeachAtimeA-ACORRECTAANSWERSA-
D.AEverydayAandAatAtheAsameAdistanceAfromAtheApatientAeachAtime
ItAisAimportantAtoAmonitorAaAradioiodineAtherapyApatientAdailyAtoAdetermineAtheAearliestApos
sibleAreleaseAfromAisolation.ATheAmeasurementAshouldAbeAperformedAusingAtheAsameAinst
rumentAandAcountingAgeometryAeachAtimeAtheAradiationAlevelAisAmonitoredAtoApermitAcomp
arisonAofAmeasurements
TheAfunctionAofAaAdrawAsheetAisAtoAprovide
A.ASupportAforAtheApatientAduringAaAstretcherAtoAbedAtransferA
B.AWarmthAtoAtheApatientAduringAtheAprocedure
C.AProtectionAfromAinfectiousAdisease
D.APatientAprivacyAduringAanAimagingAprocedure
E.AAnAactivityAforAtheApatientAduringAtransferA-ACORRECTAANSWERSA-
A.ASupportAforAtheApatientAduringAaAstretcherAtoAbedAtransfer
AAgatedAequilibriumAventricularAfunctionAstudyAcanAbeAperformedAwithAwhichAofAtheAfollowi
ngA99mTcAlabeledAtracers
A.APentetateA
B.AMedronate
C.AHumanASerumAAlbumin
D.APyrophosphateA
E.AMacroAAggregatedAAlbuminA-ACORRECTAANSWERSA-C.AHumanASerumAAlbumin
AnAequilibriumAventricularAfunctionAstudyArequiresAaAradiopharmaceuticalAthatAremainsAinA
theAbloodApool.AManyAdepartmentsAlabelAtheApatientsAredAbloodAcellsAwithA99mTcAPertech
netate,AbutAotherAfacilitiesApreferAtheAimmediateAavailabilityAofA99mTc-
Albumin.ACurrentlyA99mTcAalbuminAisAavailableAonlyAoutsideAtheAUS
WhichAofAtheAfollowingAdiagramsAisAaAcorrectlyAlabeledArepresentativeAsliceAofAtheAhorizon
talAlongAaxisAofAtheAleftAventricularAmyocardiumA
(NumberA11AofAExamA3,ApageA268)
A.ATransaxial
B.AShortAAxis
C.AHorizontalALongAAxis
D.AVerticalALongAAxisA-ACORRECTAANSWERSA-C.AHorizontalALongAAxis
(LooksAlikeAupsideAdownAU,AleftAsideAofAUAisAseptum,AtopAofAUAisAapex,ArightAsideAofAUAisAlat
eralAwall,AbottomAofAUAisAbase)
, Stress-
restAmyocardialAimagingAperformedAwithA99mTcAsestamibiArequiresAtwoAadministrationsAo
fAtracerAbecauseAtheAtracer
A.ADoesAnotAredistributeAonceAitAhasAbeenAtakenAupAbyAtheAmyocardium
B.ARapidlyAwashesAoutAofAtheAmyocardiumAafterAadministrationA
C.AHasAtooAshortAaAhalfAlifeAtoApermitAdelayedAimaging
D.AMustAbeAadministeredAimmediatelyAafterAitsApreparationA
E.AHasAaAfastAbiologicalAhalfAlifeA-ACORRECTAANSWERSA-
A.ADoesAnotAredistributeAonceAitAhasAbeenAtakenAupAbyAtheAmyocardiumA
99mTcASestamibiAisAtakenAupAintoAtheAmyocardiumAinAproportionAtoAbloodAflow.AItAisAtakenA
intoAtheAmyocardialAcells,AboundAandAretainedAinAtheAmyocardium.AThereforeAitAdoesAnotAr
edistributeAtheAwayA201TlAThallousAChlorideAdoes,AmakingAitAnecessaryAtoAadministerAtrac
erAforAbothAtheAstressAandArestAportionsAofAtheAexamination
InAaAnormalAHepatobiliaryAstudyAwhichAofAtheAfollowingAstructuresAwillAnotAbeAvisualized?
A.ALiver
B.ACommonAbileAduct
C.ASpleenA
D.AGallbladder
E.AIntestinesA-ACORRECTAANSWERSA-C.ASpleen
HepatobiliaryAagentsAareAclearedAfromAtheAbloodAbyAtheAhepatocytesAinAtheAliver.ATheAtrac
erAisAclearedAfromAtheAhepatocytesAintoAtheAcommonAbileAductAandAgallbladderAandAfromAt
hereAintoAtheAsmallAintestine
InApreparationAforAHepatobiliaryAimaging,ApatientsAareArequiredAtoAfastAto
A.APreventArenalAuptakeAofAtheAtracer
B.AEnhanceAliverAuptakeAofAtheAtracer
C.AMinimizeAtheAriskAofAradioactiveAemesis
D.AAvoidAstimulatingAtheAgallbladder
E.AAvoidAgastricAinterferenceA-ACORRECTAANSWERSA-
D.AAvoidAstimulatingAtheAgallbladder
IngestionAofAfoodAmayAcauseAtheAgallbladderAtoAcontract,ApotentiallyAcausingAaAfalseApositi
veAresult,AthatAisAtheAgallbladderAisAnotAvisualizedA.AWhileAtheAgallbladderAisAcontracting,Atr
acerAwillAnotAbeAableAtoAflowAintoAit
ToAdetermineAtheApotencyAofAaALeVeenAshunt,AtheAradiopharmaceuticalAisAadministeredAi
nto
A.AAAvein
B.ATheACircleAofAWillis
C.ATheAintrathecalAspaceA
D.ATheAshuntAtubing
E.ATheAperitonealAcavityA-ACORRECTAANSWERSA-E.ATheAperitonealAcavity
TheAphysicianAperformsAanAintraperitonealAinjectionAofAtracer
WhichAofAtheAfollowingAisAtheAcorrectApatient/cameraApositioningAforAimagingAaAtransplante
dAkidney
Answers 2025
StaticAboneAimagingAisAperformedAseveralAhoursAafterAtracerAadministrationAtoApermit
A.AMaximumAtracerAuptakeAinAtheAskeleton
B.ATracerAclearanceAfromAnormalAboneAtissue
C.ATracerAclearanceAfromAsitesAofAinfiltrationA
D.ABloodAclearanceAofAexcessAtracer
E.ATracerAclearanceAfromAtheAkidneysA-ACORRECTAANSWERSA-
D.ABloodAclearanceAofAexcessAtracer
MaximumAskeletalAuptakeAofA99mTcAMedronateAandA99mTcAOxidronateAoccursAwithinA45
minAafterAtracerAadministrationAandAimagingAisAtoAallowAtheAexcessAcirculatingAtracerAtoAbe
AclearedAfromAtheAbloodAbyAtheAkidneys.ASuchAcleaenceAisAnecesaryAtoAincreaseAtheAtarge
tA(bone)AnonAtargetA(softAtissue)AratioAforAanAoptimalAimage
ForAwhichAofAtheAfollowingAclinicalAindicationsAwouldAlimitedAboneAimagingA("spot"Aviews)A
beAmostAappropriateA
A.ARuleAoutAskeletalAmetastasesA
B.AEvaluateAPaget'sAdisease
C.AEvaluateAtemporomandibularAjointApain
D.AWithAhistoryAofAchidAabuse,AruleAoutAoccultAfractures
E.ARuleAoutAkidneyAstonesA-ACORRECTAANSWERSA-
C.AEvaluateATemporomandibularAjointApain
A,AB,ACAtendAtoAwidespreadAthroughoutAtheAskeletalAsystem.AForAtheseAaAtotalAboneAimagi
ngAisAindicated.AForATMJAimagingAspotAviewAimagingAofAtheAskullAfaceAandAcervicalAspineAi
sAindicated
ThreeAorAfourAphaseAboneAimagingAisAparticularlyAusefulAwhenAwhichAofAtheAfollowingAcon
ditionsAisAsuspected
A.AOsteomyelitisA
B.AOsteoporosisA
C.ASkeletalAMetastasesA
D.AStressAfractureA
E.ACompoundAfractureA-ACORRECTAANSWERSA-A.AOsteomyelitis
EarlyAimagesAareAimportantAinAdiagnosingAinflammatoryAconditionsAsuchAasAosteomyelitis.
ATheAflowAstudy,AtheAfirstAphaseAofAaAmultiphaseAboneAimageAisAimportantAinAdemonstratin
gAincreasedAbloodAflowAtoAtheAaffectedAarea.AInAosteomyelitisAtracerAconcentrationAremain
sAincreasedAthroughoutAtheAotherAphases
TheAstandardAviewsAperformedAinAaAlungAperfusionAstudyAare
A.AAnteriorAandAposteriorAonly
B.APosteriorAandAobliquesAonly
,C.AAnterior,AposteriorAandAlateralAofAtheAaffectedAlung
D.ALateralsAandAobliquesAonlyA
E.AAnterior,Aposterior,Alateral,AandAobliquesA-ACORRECTAANSWERSA-
E.AAnterior,APosterior,ALateral,AObliques
AtAleastA6AviewsAshouldAbeAperformedAinAaAlungAperfusionAstudyA(someArequireA8Aviews)
Anterior,Aposterior,ArightAandAleftAlaterals,ArightAandAleftAposteriorAobliques.ASometimesArig
htAandAleftAanteriorAobliques
UponAcompletionAofAanAimagingAprocedureAtheApatientAsitsAupAquicklyAandAcomplainsAofAdi
zzinessAandAfeelingAfaint.ATheAmostAappropriateAactionAforAtheAtechnologistAwouldAbeAto
A.AHaveAtheApatientAstandAandAwalkAaroundAtheAroomA
B.ACheckAvitalAsigns
C.AHaveAtheApatientAlieAdownAagain
D.ATalkAwithAtheApatientAandAhaveAtheApatientAbreatheAslowlyAandAdeeplyA
E.AAskAtheApatientAifAtheyAhaveAaAfamilyAhistoryAofAsyncopeA-ACORRECTAANSWERSA-
D.ATalkAwithApatientAandAhaveAtheApatientAbreatheAslowlyAandAdeeply
AllAofAtheAfollowingAstatementsAaboutAperformingAaAlungAventilationAstudyAwithA99mTcAPen
tetateAaerosolAareAtrueAexcept
A.AMultipleAprojectionsAmayAbeAobtainedAwithAoneAdoseAofAtracer
B.ATheApatientAisAdisconnectedAfromAtheAnebulizerAafterAinhalationAofAtheAaerosolA
C.ATheApatientAisAimagedAwhileAinhalingAparticlesAfromAtheAnebulizer
D.ATheAfaceAmask,AtubingAandAnebulizerAmustAbeAdisposedAofAasAradioactiveAwaste
E.ASomeAresidualAtracerAmayAbeApresentAinAtheAesophagusA-ACORRECTAANSWERSA-
C.ATheApatientAisAimagedAwhileAinhalingAparticlesAfromAtheAnebulizerA
ToAperformAaAventilationAstudyAwithA99mTcAPentetateAaerosolAtheAliquidAtracerAisAplacedAi
ntoAtheAnebulizerAwhereAitAisAbrokenAupAintoAsmallAairborneAparticlesAthatAareAinhaledAbyAth
eApatient.ATheApatientAisAconnectedAtoAtheAnebulizerAwithAtubingAandAaAfaceAmaskAorAmout
hpiece.AAfterAinhalationAofAtheAtracer,AtheApatientAisAdisconnectedAfromAapparatus.AThenAt
heApatientAisAimaged.ABecauseAtheAparticlesAremainAwhereAtheyAhaveAbeenAdepositedAforA
aAperiodAofAtime,AtheAsameAviewsAthatAareAacquiredAforAtheAperfusionAimagesAmayAbeAacq
uiredAforAtheAventilationAimages.ATheAnebulizer,AtubingAandAfaceAmaskAallAareAcontaminat
edAandAmustAbeAhandledAasAradioactiveAwaste
TheApurposeAofAwrappingAtheAlegsAwithAelasticAbandagesAbeforeAperformingAaAradionuclid
eAvenogramAwithA99mTcAMAAAisAto
A.ADistendAtheAveinsAinAtheAfeet
B.APreventAbloodAclotsAfromAtravelingAtoAtheAlung
C.ASuppressAsuperficialAcirculationA
D.ATrapAtheAtracerAonAtheAlowerAextremitiesA
E.AIncreaseAlowAbloodApressureAinAtheApatientA-ACORRECTAANSWERSA-
C.ASuppressAsuperficialAcirculation
A
TheApurposeAofAradionuclideAvenographyAisAtoAdemonstrateAtheApresenceAofAthrombiAinAth
eAdeepAveinsAofAtheAlegsAandApelvisA(internalAiliac).AThereforeAelasticAbandagesAareAusedAt
,oAwrapAtheAlegsAbetweenAtheAanklesAandAkneesAtoAdiverAbloodAflowAfromAtheAsuperficialAcir
culationAtoAtheAdeepAvenousAsystem
WhenAtheAradiationAlevelAcomingAfromAaAradioiodineAtherapyApatientAinAisolationAisAmeasu
red,AitAshouldAbeAmeasured
A.AEveryAday
B.AEveryAdayAatAtheAsameAtime
C.AAtAtheAsameAdistanceAfromAtheApatientAeachAtime
D.AEveryAdayAandAatAtheAsameAdistanceAfromAtheApatientAeachAtime
E.AAtAdifferentAdistancesAfromAtheApatientAeachAtimeA-ACORRECTAANSWERSA-
D.AEverydayAandAatAtheAsameAdistanceAfromAtheApatientAeachAtime
ItAisAimportantAtoAmonitorAaAradioiodineAtherapyApatientAdailyAtoAdetermineAtheAearliestApos
sibleAreleaseAfromAisolation.ATheAmeasurementAshouldAbeAperformedAusingAtheAsameAinst
rumentAandAcountingAgeometryAeachAtimeAtheAradiationAlevelAisAmonitoredAtoApermitAcomp
arisonAofAmeasurements
TheAfunctionAofAaAdrawAsheetAisAtoAprovide
A.ASupportAforAtheApatientAduringAaAstretcherAtoAbedAtransferA
B.AWarmthAtoAtheApatientAduringAtheAprocedure
C.AProtectionAfromAinfectiousAdisease
D.APatientAprivacyAduringAanAimagingAprocedure
E.AAnAactivityAforAtheApatientAduringAtransferA-ACORRECTAANSWERSA-
A.ASupportAforAtheApatientAduringAaAstretcherAtoAbedAtransfer
AAgatedAequilibriumAventricularAfunctionAstudyAcanAbeAperformedAwithAwhichAofAtheAfollowi
ngA99mTcAlabeledAtracers
A.APentetateA
B.AMedronate
C.AHumanASerumAAlbumin
D.APyrophosphateA
E.AMacroAAggregatedAAlbuminA-ACORRECTAANSWERSA-C.AHumanASerumAAlbumin
AnAequilibriumAventricularAfunctionAstudyArequiresAaAradiopharmaceuticalAthatAremainsAinA
theAbloodApool.AManyAdepartmentsAlabelAtheApatientsAredAbloodAcellsAwithA99mTcAPertech
netate,AbutAotherAfacilitiesApreferAtheAimmediateAavailabilityAofA99mTc-
Albumin.ACurrentlyA99mTcAalbuminAisAavailableAonlyAoutsideAtheAUS
WhichAofAtheAfollowingAdiagramsAisAaAcorrectlyAlabeledArepresentativeAsliceAofAtheAhorizon
talAlongAaxisAofAtheAleftAventricularAmyocardiumA
(NumberA11AofAExamA3,ApageA268)
A.ATransaxial
B.AShortAAxis
C.AHorizontalALongAAxis
D.AVerticalALongAAxisA-ACORRECTAANSWERSA-C.AHorizontalALongAAxis
(LooksAlikeAupsideAdownAU,AleftAsideAofAUAisAseptum,AtopAofAUAisAapex,ArightAsideAofAUAisAlat
eralAwall,AbottomAofAUAisAbase)
, Stress-
restAmyocardialAimagingAperformedAwithA99mTcAsestamibiArequiresAtwoAadministrationsAo
fAtracerAbecauseAtheAtracer
A.ADoesAnotAredistributeAonceAitAhasAbeenAtakenAupAbyAtheAmyocardium
B.ARapidlyAwashesAoutAofAtheAmyocardiumAafterAadministrationA
C.AHasAtooAshortAaAhalfAlifeAtoApermitAdelayedAimaging
D.AMustAbeAadministeredAimmediatelyAafterAitsApreparationA
E.AHasAaAfastAbiologicalAhalfAlifeA-ACORRECTAANSWERSA-
A.ADoesAnotAredistributeAonceAitAhasAbeenAtakenAupAbyAtheAmyocardiumA
99mTcASestamibiAisAtakenAupAintoAtheAmyocardiumAinAproportionAtoAbloodAflow.AItAisAtakenA
intoAtheAmyocardialAcells,AboundAandAretainedAinAtheAmyocardium.AThereforeAitAdoesAnotAr
edistributeAtheAwayA201TlAThallousAChlorideAdoes,AmakingAitAnecessaryAtoAadministerAtrac
erAforAbothAtheAstressAandArestAportionsAofAtheAexamination
InAaAnormalAHepatobiliaryAstudyAwhichAofAtheAfollowingAstructuresAwillAnotAbeAvisualized?
A.ALiver
B.ACommonAbileAduct
C.ASpleenA
D.AGallbladder
E.AIntestinesA-ACORRECTAANSWERSA-C.ASpleen
HepatobiliaryAagentsAareAclearedAfromAtheAbloodAbyAtheAhepatocytesAinAtheAliver.ATheAtrac
erAisAclearedAfromAtheAhepatocytesAintoAtheAcommonAbileAductAandAgallbladderAandAfromAt
hereAintoAtheAsmallAintestine
InApreparationAforAHepatobiliaryAimaging,ApatientsAareArequiredAtoAfastAto
A.APreventArenalAuptakeAofAtheAtracer
B.AEnhanceAliverAuptakeAofAtheAtracer
C.AMinimizeAtheAriskAofAradioactiveAemesis
D.AAvoidAstimulatingAtheAgallbladder
E.AAvoidAgastricAinterferenceA-ACORRECTAANSWERSA-
D.AAvoidAstimulatingAtheAgallbladder
IngestionAofAfoodAmayAcauseAtheAgallbladderAtoAcontract,ApotentiallyAcausingAaAfalseApositi
veAresult,AthatAisAtheAgallbladderAisAnotAvisualizedA.AWhileAtheAgallbladderAisAcontracting,Atr
acerAwillAnotAbeAableAtoAflowAintoAit
ToAdetermineAtheApotencyAofAaALeVeenAshunt,AtheAradiopharmaceuticalAisAadministeredAi
nto
A.AAAvein
B.ATheACircleAofAWillis
C.ATheAintrathecalAspaceA
D.ATheAshuntAtubing
E.ATheAperitonealAcavityA-ACORRECTAANSWERSA-E.ATheAperitonealAcavity
TheAphysicianAperformsAanAintraperitonealAinjectionAofAtracer
WhichAofAtheAfollowingAisAtheAcorrectApatient/cameraApositioningAforAimagingAaAtransplante
dAkidney