S-12 CITYWIDE SPRINKLER SYSTEMS EXAM SCRIPT 2025/2026 QUESTIONS WITH ANSWERS RATED A+ WET PIPE SYSTEMS HAVE WATER AT A MINIMUM TEMP. OF _______ TO PREVENT THE SYSTEM FROM FREEZING. - 40 FAHRENHEIT __________ VALVES ARE NO LONGER PERMITTED TO BE INSTALLED. - COLD WEATHER ________ SYSTEMS ARE INSTALLED WHERE A WET PIPE SYSTEM CANNOT BE HEATED TO PREVENT FREEZING. - DRY PIPE THE DROP IN ________ CAUSES A SPECIAL DRY PIPE VALVE TO OPEN. - AIR PRESSURE IN BUILDINGS WHERE LIFE HAZARD IS HIGH (SCHOOLS, HOSPITALS) THE ALARM IS TRANSMI

Content preview

S-12 CITYWIDE SPRINKLER SYSTEMS EXAM SCRIPT
2025/2026 QUESTIONS WITH ANSWERS RATED A+
✔✔WET PIPE SYSTEMS HAVE WATER AT A MINIMUM TEMP. OF _______ TO
PREVENT THE SYSTEM FROM FREEZING. - ✔✔40 FAHRENHEIT

✔✔__________ VALVES ARE NO LONGER PERMITTED TO BE INSTALLED. -
✔✔COLD WEATHER

✔✔________ SYSTEMS ARE INSTALLED WHERE A WET PIPE SYSTEM CANNOT
BE HEATED TO PREVENT FREEZING. - ✔✔DRY PIPE

✔✔THE DROP IN ________ CAUSES A SPECIAL DRY PIPE VALVE TO OPEN. -
✔✔AIR PRESSURE

✔✔IN BUILDINGS WHERE LIFE HAZARD IS HIGH (SCHOOLS, HOSPITALS) THE
ALARM IS TRANSMITTED DIRECTLY TO THE _________. - ✔✔FIRE DEPARTMENT

✔✔DRY PIPE VALVES ARE OF A ______ DESIGN. - ✔✔CLAPPER

✔✔DRY PIPE VALVES ARE USUALLY SET AT ________ PSI ABOVE THE NORMAL
TRIP LEVEL. - ✔✔15-20

✔✔AN ACCELERATOR AND EXHAUSTER ARE USED TO _______THE TIME TO
ALLOW WATER INTO THE SYSTEM. - ✔✔REDUCE

✔✔BOTH ACCLERATOR AND EXHAUSTER ARE ACTIVATED WHEN A DROP OF
_______ PSI IS DETECTED IN THE SYSTEM. - ✔✔2

✔✔IN A PREACTION SYSTEM, THE ___________ IS OPENED BEFORE THE
SPRINKLER HEADS. - ✔✔PREACTION VALVE

✔✔PREACTION SYSTEM ALARMS ARE GIVEN AS SOON AS THE _________ IS
OPENED. - ✔✔VALVE

✔✔THREE DEVICES USED TO TRIP PREACTION VALVES ARE FIXED TEMP
DEVICES, RATE DEVICES, AND ___________ DEVICES. - ✔✔COMBINATION

✔✔THE _________ FEATURE SHUTS OFF WATER WHEN THE FIRE IS
EXTINGUISHED AND TURNS ON AGAIN IF THE FIRE REKINDLES. -
✔✔RECYCLING

,✔✔THE ________ IN THE DELUGE SYSTEM ARE OPEN AT ALL TIMES. -
✔✔SPRINKLER HEADS

✔✔_________ SYSTEMS ARE USUALLY FOUND IN BASEMENTS OR OTHER
DIFFICULT TO REACH AREAS. - ✔✔PERFORATED PIPE

✔✔________ NOZZLES ARE USED FOR TRANSFORMER VAULTS AND OTHER
HAZARDOUS AREAS. - ✔✔OPEN-FIXED

✔✔EXTERIOR EXPOSURE SPRINKLERS USE OPEN SPRINKLER HEADS TO
FORM A _______ ON THE WALL OF A BUILDING. - ✔✔WATER CURTAIN

✔✔_________ SYSTEMS ARE USED FOR THE PROTECTION OF SPECIAL
HAZARDOUS OCCUPANCIES. - ✔✔FOAM SUPPLY

✔✔THE COF HOLDER SHALL KNOW THE LOCATION OF ALL SPRINKLER HEADS,
CONTROL VALVES, SUPPLY LINES AND _________ ROOMS. - ✔✔COMPACTOR

✔✔A SIGN INDICATING THE LOCATION OF ALL _______ SHALL BE KEPT IN THE
COMPACTOR ROOM. - ✔✔CONTROL VALVES

✔✔ALL INDICATING VALVES IN THE COMPACTOR SPRINKLER SYSTEM SHALL
BE ________ OPEN. - ✔✔SEALED

✔✔A MINIMUM OF _________ EXTRA SPRINKLER HEADS WITH THE
APPROPRIATE WRENCHES SHALL BE AVAILABLE TO REPLACED DAMAGED
ONES - ✔✔6

✔✔THE COF HOLDER SHALL CONDUCT AN INSPECTION OF THE ENTIRE
SPRINKLER SYSTEM AT LEAST __________. - ✔✔ONCE A MONTH

✔✔AUTOMATIC BALL DRIP DEVICES SHALL BE INSTALLED IN THE _________
POSITION. - ✔✔HORIZONTAL

✔✔IF THE SPRINKLER SYS. IS SUPPLIED FROM PUBLIC WATER MAIN, THE
CONTROL VALVE SIGN MAY READ ________________. - ✔✔"SHUTOFF FOR
SPRINKLER SYS. LOCATED 6 FEET FROM THIS SIGN"

✔✔GATE VALVES OF THE NON-INDICATING TYPE ARE CALLED ________. -
✔✔CURB VALVES

, ✔✔IN AN OUTSIDE STEM AND YOLK VALVE (OS&Y), VALVE POSITION IS
INDICATED BY THE POSITION OF THE ____________. - ✔✔STEM

✔✔ON A POST INDICATOR VALVE (PIV), THE POSITION OF THE VALVE IS
SHOWN THROUGH A ___________. - ✔✔TELLTALE

✔✔FDNY CONNECTIONS TO AUTOMATIC SPRINKLER SYSTEMS SHALL BE
PAINTED ___________. - ✔✔GREEN

✔✔FDNY CONNECTIONS TO NON-AUTOMATIC SPRINKLER SYSTEMS SHALL BE
PAINTED ___________. - ✔✔SILVER

✔✔FDNY CONNECTIONS TO STANDPIPE SYSTEMS SHALL BE PAINTED
____________. - ✔✔RED

✔✔FDNY CONNECTIONS TO A COMBINED STANDPIPE/SPRINKLER SYSTEM
SHALL BE PAINTED ___________. - ✔✔YELLOW

✔✔FDNY CONNECTIONS SHALL BE FITTED WITH A LOWER CHECK VALVE. THIS
WILL PREVENT ________ OF WATER. - ✔✔BACKFLOW

✔✔PRESSURE TANKS SHOULD BE KEPT ________ FULL AND BE MAINTAINED
AT OR ABOVE ________ PSI. - ✔✔2/3, 75

✔✔___________ ARE DESIGNED TO TAKE WATER FROM A SUPPLY AND
DISCHARGE IT UNDER PRESSURE. - ✔✔FIRE PUMPS

✔✔AUTOMATIC FIRE PUMPS ARE USUALLY NEEDED WHERE A ___________
MAY OCCUR IMMEDIATELY. - ✔✔HIGH WATER DEMAND

✔✔WATER ALARMS SERVE AS FIRE EXTINGUISHING SYSTEMS AND SERVE AS
A(N) _________. - ✔✔AUTOMATIC FIRE ALARM.

✔✔SPRINKLER SYSTEMS ARE REQUIRED TO HAVE AN APPROVED MOTOR
GONG, BELL, HORN, OR ________. - ✔✔SIREN

✔✔SPRINKLERS MANUFACTURED AFTER 1/1/2000 ARE REQUIRED TO HAVE A
_____________. - ✔✔SPRINKLER IDENTIFICATION NUMBER (SIN)

✔✔_________ SPRINKLERS HAVE BEEN RECALLED. - ✔✔CYCLING

Document information

Uploaded on
May 6, 2025
Number of pages
17
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$12.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
BOARDWALK
3.5
(41)
Sold
287
Followers
11
Items
36004
Last sold
6 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions