S-12 CITYWIDE SPRINKLER SYSTEMS 2025/2026 QUESTIONS WITH ANSWERS RATED A+ the cof holder shall know the location of all sprinkler heads, control valves, supply lines and _________ rooms. - compactor a sign indicating the location of all _______ shall be kept in the compactor room. - control valves all indicating valves in the compactor sprinkler system shall be ________ open. - sealed a minimum of _________ extra sprinkler heads with the appropriate wrenches shall be available to replaced damaged ones - 6 the cof holder shall conduct an inspection of the entire sprinkler system at least __________. - once a month automatic ball drip devices shal

Content preview

S-12 CITYWIDE SPRINKLER SYSTEMS 2025/2026
QUESTIONS WITH ANSWERS RATED A+
✔✔the cof holder shall know the location of all sprinkler heads, control valves, supply
lines and _________ rooms. - ✔✔compactor

✔✔a sign indicating the location of all _______ shall be kept in the compactor room. -
✔✔control valves

✔✔all indicating valves in the compactor sprinkler system shall be ________ open. -
✔✔sealed

✔✔a minimum of _________ extra sprinkler heads with the appropriate wrenches shall
be available to replaced damaged ones - ✔✔6

✔✔the cof holder shall conduct an inspection of the entire sprinkler system at least
__________. - ✔✔once a month

✔✔automatic ball drip devices shall be installed in the _________ position. -
✔✔horizontal

✔✔if the sprinkler sys. Is supplied from public water main, the control valve sign may
read ________________. - ✔✔"shutoff for sprinkler sys. Located 6 feet from this sign"

✔✔gate valves of the non-indicating type are called ________. - ✔✔curb valves

✔✔in an outside stem and yolk valve (os&y), valve position is indicated by the position
of the ____________. - ✔✔stem

✔✔on a post indicator valve (piv), the position of the valve is shown through a
___________. - ✔✔telltale

✔✔fdny connections to automatic sprinkler systems shall be painted ___________. -
✔✔green

✔✔fdny connections to non-automatic sprinkler systems shall be painted ___________.
- ✔✔silver

✔✔fdny connections to standpipe systems shall be painted ____________. - ✔✔red

✔✔fdny connections to a combined standpipe/sprinkler system shall be painted
___________. - ✔✔yellow

, ✔✔fdny connections shall be fitted with a lower check valve. This will prevent ________
of water. - ✔✔backflow

✔✔pressure tanks should be kept ________ full and be maintained at or above
________ psi. - ✔✔2/3, 75

✔✔___________ are designed to take water from a supply and discharge it under
pressure. - ✔✔fire pumps

✔✔automatic fire pumps are usually needed where a ___________ may occur
immediately. - ✔✔high water demand

✔✔water alarms serve as fire extinguishing systems and serve as a(n) _________. -
✔✔automatic fire alarm.

✔✔sprinkler systems are required to have an approved motor gong, bell, horn, or
________. - ✔✔siren

✔✔sprinklers manufactured after 1/1/2000 are required to have a _____________. -
✔✔sprinkler identification number (sin)

✔✔_________ sprinklers have been recalled. - ✔✔cycling

✔✔sprinkler heads exposed to ___________ conditions are often covered with a coat of
wax, or lead. - ✔✔corrosive

✔✔at a distance of 4 feet below the deflector, the spray pattern covers a diameter of
_________ feet when discharging at 15 gpm. - ✔✔16

✔✔large drop sprinkler heads are used to break through the strong __________ of high
challenge fires. - ✔✔updrafts

✔✔if a fire has been completely extinguished, the __________ or their representative
may close the control valve. - ✔✔building owner

✔✔build up of foreign materials on sprinkler heads is commonly called _________. -
✔✔loading

✔✔spare sprinklers shall be kept at the facility when the temperature does not exceed
_________. - ✔✔100 degrees fahrenheit

Document information

Uploaded on
May 6, 2025
Number of pages
8
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$12.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
BOARDWALK
3.5
(41)
Sold
287
Followers
11
Items
36004
Last sold
6 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions