Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 8 pages
Exam (elaborations)

S-12 CITYWIDE SPRINKLER SYSTEMS EXAM STUDY GUIDE 2025/2026 QUESTIONS WITH ANSWERS RATED A+

Document preview thumbnail
Preview 2 out of 8 pages

S-12 CITYWIDE SPRINKLER SYSTEMS EXAM STUDY GUIDE 2025/2026 QUESTIONS WITH ANSWERS RATED A+ glycerin not greater than _________ percent or glycol not greather than ________ percent shall be used to protect from freezing. - 50, 40 the cof number and signature of cof holder shall be posted near the ____________. - main control valve __________ shall be readily available to any representative of the fire dept. These are to be maintained on site for 3 years. - records failure to make inspections may result in __________ of the cof and court proceedings. - revocation the cof holder may inspect, test, and perform routine mx if they hold the following certs: - refrigeration operating engineer, high pressure operating engineer, and nys high pressure operating engineer

Content preview

S-12 CITYWIDE SPRINKLER SYSTEMS EXAM STUDY GUIDE
2025/2026 QUESTIONS WITH ANSWERS RATED A+
✔✔glycerin not greater than _________ percent or glycol not greather than ________
percent shall be used to protect from freezing. - ✔✔50, 40

✔✔the cof number and signature of cof holder shall be posted near the ____________.
- ✔✔main control valve

✔✔__________ shall be readily available to any representative of the fire dept. These
are to be maintained on site for 3 years. - ✔✔records

✔✔failure to make inspections may result in __________ of the cof and court
proceedings. - ✔✔revocation

✔✔the cof holder may inspect, test, and perform routine mx if they hold the following
certs: - ✔✔refrigeration operating engineer, high pressure operating engineer, and nys
high pressure operating engineer.

✔✔a ________ can inspect, maintain, test, and repair all fire standpipe and sprinkler
systems. - ✔✔master fire suppression piping contractor (mfspc)

✔✔a master plumber (mp) with cof is limited to residential occupancies with _________
sprinkler heads or less. - ✔✔30

✔✔about ______ percent of fires are extinguished or controlled when sprinklers are
installed. - ✔✔96

✔✔wet pipe systems have water at a minimum temp. Of _______ to prevent the system
from freezing. - ✔✔40 fahrenheit

✔✔__________ valves are no longer permitted to be installed. - ✔✔cold weather

✔✔________ systems are installed where a wet pipe system cannot be heated to
prevent freezing. - ✔✔dry pipe

✔✔the drop in ________ causes a special dry pipe valve to open. - ✔✔air pressure

✔✔in buildings where life hazard is high (schools, hospitals) the alarm is transmitted
directly to the _________. - ✔✔fire department

✔✔dry pipe valves are of a ______ design. - ✔✔clapper

, ✔✔dry pipe valves are usually set at ________ psi above the normal trip level. - ✔✔15-
20

✔✔an accelerator and exhauster are used to _______the time to allow water into the
system. - ✔✔reduce

✔✔both acclerator and exhauster are activated when a drop of _______ psi is detected
in the system. - ✔✔2

✔✔in a preaction system, the ___________ is opened before the sprinkler heads. -
✔✔preaction valve

✔✔preaction system alarms are given as soon as the _________ is opened. - ✔✔valve

✔✔three devices used to trip preaction valves are fixed temp devices, rate devices, and
___________ devices. - ✔✔combination

✔✔the _________ feature shuts off water when the fire is extinguished and turns on
again if the fire rekindles. - ✔✔recycling

✔✔the ________ in the deluge system are open at all times. - ✔✔sprinkler heads

✔✔_________ systems are usually found in basements or other difficult to reach areas.
- ✔✔perforated pipe

✔✔________ nozzles are used for transformer vaults and other hazardous areas. -
✔✔open-fixed

✔✔exterior exposure sprinklers use open sprinkler heads to form a _______ on the wall
of a building. - ✔✔water curtain

✔✔_________ systems are used for the protection of special hazardous occupancies. -
✔✔foam supply

✔✔the cof holder shall know the location of all sprinkler heads, control valves, supply
lines and _________ rooms. - ✔✔compactor

✔✔a sign indicating the location of all _______ shall be kept in the compactor room. -
✔✔control valves

Document information

Uploaded on
May 6, 2025
Number of pages
8
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$12.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
BOARDWALK
3.5
(41)
Sold
287
Followers
11
Items
36004
Last sold
6 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions