The discharge outlet of a safety valve must correct answers Be as short and straight as possible and arranged to avoid stress on the pipe An altitude gauge is required on a hot water supply boiler when the altitude is more than how many feet correct answers 20 The most appropriate valve application for a surface blow down system would be what valve correct answers Meter valve a safety valve over 3" and over 15 psig shall have what type of inlet connection? correct answers flanged or welded The appropriate valve application for a boiler blow off valve on a high pressure boiler is a correct answers Y- Type Globe Valve Which form of Safety Valve mounting is not permissible in the Heating Boiler Code? correct answers To an internal pipe in the boiler Which is true regarding a boiler water column correct answers Reduces the turbulence of the water to give a more accurate reading in the gauge glass Two Low Water cut-offs are required on a steam heating boiler when correct answers The Boiler has pumped condensate returns and has an input over 200,000 BTU When piping low water fuel cutoff devices to a boiler, the devices must be piped to what height in relation to the level of the gauge glass? correct answers Lowest visible part of the water gauge glass

Content preview

Journeyman Pipefitter Test || correct answers 100%.

The discharge outlet of a safety valve must correct answers Be as short and straight as possible
and arranged to avoid stress on the pipe


An altitude gauge is required on a hot water supply boiler when the altitude is more than how
many feet correct answers 20


The most appropriate valve application for a surface blow down system would be what valve
correct answers Meter valve


a safety valve over 3" and over 15 psig shall have what type of inlet connection? correct answers
flanged or welded


The appropriate valve application for a boiler blow off valve on a high pressure boiler is a correct
answers Y- Type Globe Valve


Which form of Safety Valve mounting is not permissible in the Heating Boiler Code? correct
answers To an internal pipe in the boiler


Which is true regarding a boiler water column correct answers Reduces the turbulence of the
water to give a more accurate reading in the gauge glass


Two Low Water cut-offs are required on a steam heating boiler when correct answers The Boiler
has pumped condensate returns and has an input over 200,000 BTU


When piping low water fuel cutoff devices to a boiler, the devices must be piped to what height
in relation to the level of the gauge glass? correct answers Lowest visible part of the water gauge
glass

, A 3/4 blow off may be used on a high pressure boiler if the boiler heating surface is less than
how many square feet on the heating surface correct answers 100'


Which device shall cause a safety shutdown (lockout) requiring a manual reset correct answers
Auxiliary low water cut-off with a manual reset


The required boiler feedwater stop valve on a high pressure boiler is located between what
correct answers The boiler and the check valve


The return pipe connections of each boiler supplying a gravity return steam heating system shall
be so arranged as to form a loop so that the water in each boiler cannot be forced out below the
safe water level. This loop is most commonly known as correct answers The Hartford steam loop


When are steam valves required correct answers Each boiler outlet


When is a Pipefitter license required and under what law correct answers Anything over 700,000
BTU (522) CMR


The bourdon tube of a steam pressure gauge must be protected by correct answers Loop seal,
siphon, pigtail


What is the minimum size of the drain pipe and the blow off valve required on a low water cutoff
that has a separate float chamber correct answers 3/4"


The valve that offers the least resistance to flow is what correct answers Gate Valve


What type of fitting must be placed in the water piping connection at every right angle to
facilitate cleaning and inspection of a water column of low water cutoff correct answers Cross
fitting

Document information

Uploaded on
May 5, 2025
Number of pages
10
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$11.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
SirAnton
3.7
(118)
Sold
807
Followers
438
Items
40070
Last sold
2 weeks ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions