• Wrong document? Swap it for free
  • Written by students who passed
  • Immediately available after payment
  • Read online or as PDF
Sell
Where do you study
Your language
Document preview thumbnail
Preview 2 out of 15 pages
Exam (elaborations)

RHODE ISLAND Journeyman/Master Plumber Exam| Questions Solved 100% Correct | Verified Answers

Document preview thumbnail
Preview 2 out of 15 pages

RHODE ISLAND Journeyman/Master Plumber Exam| Questions Solved 100% Correct | Verified Answers Water line is installed minimum 12" above sewer line at highest point - ANSWER -Water service separation distance is not required if: 50' - ANSWER -Distance for a septic tank/sewer to a private water supply(well) is: 6"below the roof with an approved fitting - ANSWER -Where frost closure is common an increase in vent size shall take place: "V" zone (subject to wave heights in excess of 3') - ANSWER -High Hazard flood zone is: 8.0% Lead - ANSWER -Lead free pipe and fittings contain less than: 110 degrees - ANSWER -Hot water is water at temperature greater than or equal to: 0.2% Lead - ANSWER -Lead free solder and flux contain no more than 0.5 inches - ANSWER -Strainer plates on drain lines for rodent proofing must have openings: Two pipe size greater than the pipe passing through it - ANSWER Sleeves for pipes passing through foundation walls or under footings shall be: 500' - ANSWER -Travel distance to toilet facilities in merchantile/occupancies are: 300' - ANSWER -Travel distance to toilet facilities in covered malls are: 15" - ANSWER -Water closets, bidets or lavatories shall have a clearance from center of fixture to wall of: 21" - ANSWER -The required clearance from front of fixture to a wall, door or other fixture is: 3" - ANSWER -Minimum size floor drains for public laundries or central washing facilities is: 1 1/2" - ANSWER -Shower waste outlets shall be minimum of: 3" - ANSWER -Minimum size removable strainer for shower compartments are: .25 inches - ANSWER -Minimum size floor drain strainer opening is: 4 pounds per square foot - ANSWER -Sheet lead shall not weigh less than: 12 ounces per square foot - ANSWER -Sheet copper shall not weigh less than: 67% - ANSWER -Urinals shall not be substituted for more than what percent of water closets? 120 degrees - ANSWER -Shower and Tub/Shower valves maximum hot water setting is: 140 degrees - ANSWER -Maximum water temperature of a tankless heater or domestic hot water heater is: 210 degrees 150 psi - ANSWER -Maximum setting of a temperature pressure and relief valve or a combination thereof is: 160 psi - ANSWER -Minimum working pressure of a domestic water service either outside or buried is: 100 psi @180 degrees - ANSWER -All hot water distribution piping and tubing shall have a minimum pressure rating of: 50 parts per million of chlorine for 24 hours - ANSWER -Disinfection of the potable water system uses: Air gap or air gap device - ANSWER -The discharge from a reverse osmosis system enters the drainage system through: Side by side in the same trench - ANSWER -Sanitary sewer and storm drains for the same property can be installed: Not less than 1" - ANSWER -Molten lead should be poured in one operation to a depth of: 0.125 inches - ANSWER -A lead pour when caulked shall not recede

Content preview

RHODE ISLAND Journeyman/Master Plumber Exam|
Questions Solved 100% Correct | Verified Answers

Water line is installed minimum 12" above sewer line at highest point -
ANSWER -Water service separation distance is not required if:

50' - ANSWER -Distance for a septic tank/sewer to a private water
supply(well) is:

6"below the roof with an approved fitting - ANSWER -Where frost
closure is common an increase in vent size shall take place:

"V" zone (subject to wave heights in excess of 3') - ANSWER -High
Hazard flood zone is:

8.0% Lead - ANSWER -Lead free pipe and fittings contain less than:

110 degrees - ANSWER -Hot water is water at temperature greater than
or equal to:

0.2% Lead - ANSWER -Lead free solder and flux contain no more than

0.5 inches - ANSWER -Strainer plates on drain lines for rodent
proofing must have openings:

Two pipe size greater than the pipe passing through it - ANSWER -
Sleeves for pipes passing through foundation walls or under footings
shall be:

, 500' - ANSWER -Travel distance to toilet facilities in
merchantile/occupancies are:

300' - ANSWER -Travel distance to toilet facilities in covered malls
are:

15" - ANSWER -Water closets, bidets or lavatories shall have a
clearance from center of fixture to wall of:

21" - ANSWER -The required clearance from front of fixture to a wall,
door or other fixture is:

3" - ANSWER -Minimum size floor drains for public laundries or
central washing facilities is:

1 1/2" - ANSWER -Shower waste outlets shall be minimum of:

3" - ANSWER -Minimum size removable strainer for shower
compartments are:

.25 inches - ANSWER -Minimum size floor drain strainer opening is:

4 pounds per square foot - ANSWER -Sheet lead shall not weigh less
than:

12 ounces per square foot - ANSWER -Sheet copper shall not weigh
less than:

67% - ANSWER -Urinals shall not be substituted for more than what
percent of water closets?

Document information

Uploaded on
May 5, 2025
Number of pages
15
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$14.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TheExamMaestro
3.6
(18)
Sold
158
Followers
5
Items
3820
Last sold
3 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions