The purpose of electrical symbols on plans is ____. - (ANSWER)to graphically represent
electrical products and systems

The National Electrical Code is a minimum ____ standard. - (ANSWER)Safety

The meaning of approved is ____. - (ANSWER)acceptable to the authority having jurisdiction
Article 100 Def.

As defined in Article 100, a dwelling unit has the following feature(s): ____. -
(ANSWER)permanent provisions for living, sleeping, cooking, and sanitation Article 100 Def.

Devices are equipment whose primary function is to carry current, not ____. - (ANSWER)utilize
electric energy Article 100 Def.

The NEC requires that a(n) ____ be installed at each conductor splice connection point. -
(ANSWER)box or conduit body NEC 300.15

In order that the connections inside an outlet box remain accessible, the NEC requires that a
surface extension from an outlet box cover be made using ____. - (ANSWER)flexible conduit
NEC 314.22 Exception

Unused knockouts in boxes, spaces for ____________________ in a panel, meter socket
enclosures, and all other similar equipment must be effectively closed. - (ANSWER)circuit
breakers NEC 110.12(A) & 408.7

Where noncombustible surface material is used on walls or ceilings, outlet boxes must be
mounted so that they will be set back not more than ____ from the face of the surface material. -
(ANSWER)1/4 in. NEC 314.20

All of the following are included when calculating the usable area of a dwelling to compute the
required lighting load, except for ____. - (ANSWER)crawl space NEC 220.12

The 20-ampere appliance circuits required by NEC are permitted to serve no other loads, except
for - (ANSWER)clock outlets and receptacles that are installed to plug in the cords of gas-fired
ranges, ovens, or counter-mounted cooking units NEC 210.52(B)(2) Exception 1 and 2

NEC Article 210 provides ____ guidelines for locating receptacle outlets in residences. -
(ANSWER)mandatory Article 210

Wall receptacles in a habitable room must be placed so they are no further than ____ feet from
any point along the wall. - (ANSWER)6 ft. NEC 210.52(A)(1)


Page 1 of 5

, A continuous load shall not exceed ____ of the rating of the branch circuit - (ANSWER)80%

The smallest wire size for which overcurrent protection is specified in the Code is ____. -
(ANSWER)14 AWG NEC 210.24, Table 210.24, and 240.3(D)(3)

The NEC requires that conductors 8 AWG and larger must be ____ when installed in a raceway.
- (ANSWER)Stranded NEC 310.106(C)

Branch circuit conductors shall have an ampacity ____ the maximum to be served. -
(ANSWER)not less than NEC 210.19(A)

The rating of a branch circuit is determined by its ____. - (ANSWER)overcurrent protective
device (fuse or circuit-breaker)

The total rating of utilization equipment fastened in place, other than luminaires (lighting
fixtures), shall not exceed ____ percent of the branch-circuit ampere rating, where lighting units,
cord and plug connected utilization equipment not fastened in place, or both, are also supplied -
(ANSWER)50% NEC 210.23(A)(2)

Table 310.15(B)(2)(a) gives allowable ampacities of copper conductors with various types of
insulation. When conductors will be used in ambient temperatures exceeding 30°C (86°F), the
____ for the table must be applied. - (ANSWER)correction factors

Article 210 applies to branch circuits, but branch-circuit calculations are covered in ____. -
(ANSWER)Article 220

Under certain circumstances, the grounded (neutral) conductors of a residential service ____
permitted to be sized smaller than the phase conductors. - (ANSWER)are NEC 215.2(A)(2) and
NEC 230.42(C)

The ampacity of Type NM cable shall be in accordance with ____ conductor temperature rating -
(ANSWER)60°C (140°F) NEC 334.80

When using individual conductors in raceway, all of the following colors of insulation are
permitted for the grounded conductor (neutral), except for ____. - (ANSWER)green with three
white stripes NEC 200.7(A)

Phase conductors 6 AWG and smaller ____ permitted to be re-identified as equipment ground
conductors using green paint, tape, or other effective means. - (ANSWER)Are Not NEC
210.5(B), NEC 250.119 and NEC 310.110(B)

The NEC requires that switching be done only in ____ conductors. - (ANSWER)ungrounded
NEC 404.2(A)

To avoid inductive heating in metallic raceways, the NEC requires that ____. - (ANSWER)all
circuit conductors be run in the same raceway NEC 300.3(B)

Page 2 of 5

Document information

Uploaded on
May 4, 2025
Number of pages
5
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$8.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
mercymutinda
5.0
(1)
Sold
4
Followers
0
Items
753
Last sold
4 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions