Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 11 pages
Exam (elaborations)

Refrigeration ESCO Exam Questions and Answers 100% Pass

Document preview thumbnail
Preview 2 out of 11 pages

©JASONMcCONNELL 2025 ALL RIGHTS RESERVED 1 Refrigeration ESCO Exam Questions and Answers 100% Pass _____ can be used for a leak detection with all high pressure refrigerant - Answersoap bubbles 10 pounds of refrigerant passing through a water cooled condenser will lose 20 BTUs of heat per pound. If 10 pounds of water passes through the condenser with an entering temperature of 80°F the temperature of the water leaving the condenser is - Answer100 degrees a compound pressure gauge measures - Answerpressure and vacuum a compressor that has a broken reed valve will cause these symptoms - Answerhigh suction pressure and low discharge pressure a customer complains that their air conditioning system is running constantly, but not cooling enough. the suction line is very cold and the compressor is sweating, the most likely cause is - Answera restriction of the return air or a dirty evaporator a customer reports that their residential split system had a compressor replaced last week by another service company. Now the unit is not cooling properly. when you arrive and inspect the unit, you find that the evaporator seems to be starved for refrigerant. on examining the condensing unit you find that the liquid line is sweating where it leaves the drier. This is most likely the result of - Answerdebris from the burned out compressor has clogged the drier ©JASONMcCONNELL 2025 ALL RIGHTS RESERVED 2 a decrease in superheat causes the thermostatic expansion valve to begin to - Answerclose A dirty evaporator in an air conditioning system will cause these symptoms - Answerlow suction pressure and low discharge pressure a faulty condenser fan motor on an air conditioning system will cause these symptoms - Answerhigh suction pressure and high discharge pressure a liquid receiver is used to - Answerstore liquid refrigerant a liquid to suction heat exchanger is often used to - Answerincrease liquid subcooling a low pressure cut off switch is used to - Answerestablish minimum operating pressure in the evaporator a low refrigerant charge in an air conditioning system will causes these symptoms - Answerlow suction pressure and low discharge pressure a mechanical shaft seal is necessary on a - Answeropen drive compressor a partially clogged capillary tube can cause - Answera starved evaporator a partially iced over evaporator can be caused by - Answeran undercharge a refrigerant gives up heat when - Answerit condenses A refrigerant overcharge in a capillary tube air conditioning system will cause these symptoms - Answerhigh suction pressure and high discharge pressure

Content preview

©JASONMcCONNELL 2025 ALL RIGHTS RESERVED




Refrigeration ESCO Exam Questions and
Answers 100% Pass




_____ can be used for a leak detection with all high pressure refrigerant - Answer✔soap
bubbles


10 pounds of refrigerant passing through a water cooled condenser will lose 20 BTUs of heat
per pound. If 10 pounds of water passes through the condenser with an entering temperature
of 80°F the temperature of the water leaving the condenser is - Answer✔100 degrees



a compound pressure gauge measures - Answer✔pressure and vacuum



a compressor that has a broken reed valve will cause these symptoms - Answer✔high suction
pressure and low discharge pressure


a customer complains that their air conditioning system is running constantly, but not cooling
enough. the suction line is very cold and the compressor is sweating, the most likely cause is -
Answer✔a restriction of the return air or a dirty evaporator


a customer reports that their residential split system had a compressor replaced last week by
another service company. Now the unit is not cooling properly. when you arrive and inspect the
unit, you find that the evaporator seems to be starved for refrigerant. on examining the
condensing unit you find that the liquid line is sweating where it leaves the drier. This is most
likely the result of - Answer✔debris from the burned out compressor has clogged the drier



1

, ©JASONMcCONNELL 2025 ALL RIGHTS RESERVED


a decrease in superheat causes the thermostatic expansion valve to begin to - Answer✔close



A dirty evaporator in an air conditioning system will cause these symptoms - Answer✔low
suction pressure and low discharge pressure


a faulty condenser fan motor on an air conditioning system will cause these symptoms -
Answer✔high suction pressure and high discharge pressure



a liquid receiver is used to - Answer✔store liquid refrigerant



a liquid to suction heat exchanger is often used to - Answer✔increase liquid subcooling



a low pressure cut off switch is used to - Answer✔establish minimum operating pressure in the
evaporator


a low refrigerant charge in an air conditioning system will causes these symptoms -
Answer✔low suction pressure and low discharge pressure



a mechanical shaft seal is necessary on a - Answer✔open drive compressor



a partially clogged capillary tube can cause - Answer✔a starved evaporator



a partially iced over evaporator can be caused by - Answer✔an undercharge



a refrigerant gives up heat when - Answer✔it condenses


A refrigerant overcharge in a capillary tube air conditioning system will cause these symptoms -
Answer✔high suction pressure and high discharge pressure

2

Document information

Uploaded on
May 1, 2025
Number of pages
11
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$11.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
StarGuide
4.3
(4)
Sold
21
Followers
0
Items
2587
Last sold
4 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions