S12 definitions UPDATED ACTUAL Exam Questions and CORRECT Answers ALARM NOTIFICATION APPLIANCE - CORRECT ANSWER - A fire alarm system component, such as a bell, horn, speaker, light, text display or vibration device that issues an audible, tactile, and/or visual alert. ALARM SIGNAL - CORRECT ANSWER - A signal indicating an emergency requiring immediate action, such as a signal indicative of fire. ANTIFREEZE SPRINKLER SYSTEM - CORRECT ANSWER - A wet pipe sprinkler system employing automatic sprinklers that are attached to a piping system that contains an antifreeze solution and is connected to a water supply. The antifreeze solution is discharged, followed by water, immediately upon operation of sprinklers opened by heat from a fire.

Content preview

S12 definitions UPDATED ACTUAL Exam
Questions and CORRECT Answers
ALARM NOTIFICATION APPLIANCE - CORRECT ANSWER - A fire alarm system
component, such as a bell, horn, speaker, light, text display or vibration device that issues an
audible, tactile, and/or visual alert.


ALARM SIGNAL - CORRECT ANSWER - A signal indicating an emergency requiring
immediate action, such as a signal indicative of fire.


ANTIFREEZE SPRINKLER SYSTEM - CORRECT ANSWER - A wet pipe sprinkler
system employing automatic sprinklers that are attached to a piping system that contains an
antifreeze solution
and is connected to a water supply. The antifreeze solution is discharged, followed by water,
immediately upon operation of sprinklers opened by heat from a fire.


AUTOMATIC BALL DRIP - CORRECT ANSWER - An automatic drain valve
horizontally installed at the low point in the piping between the lower check valve and the Fire
Department connection of automatic sprinkler systems. Water pressure from a Fire Department
pumper automatically closes this valve. It automatically re-opens when pressure ceases,
permitting this piping to drain and thereby preventing freezing.


CENTRAL STATION - CORRECT ANSWER - A facility that receives alarm signals
from a protected premises and retransmits or otherwise reports such alarm signals to the
department.


COMBINATION STANDPIPE AND SPRINKLER SYSTEM - CORRECT ANSWER -
A system where the water piping services both 21⁄2 in. (65 mm) outlets for fire
department use and outlets for automatic sprinklers.


CONCEALED SPRINKLER - CORRECT ANSWER - A recessed sprinkler with a cover
plate.

, CONTROL MODE SPECIFIC APPLICATION SPRINKLERS (CMSA) - CORRECT
ANSWER - Control mode sprinkler systems are designed to control a fire until its original
fuel source is depleted or until fire-fighting activities can commence. A fire is controlled by
cooling the ceiling-level air temperatures, reducing the fire's rate of heat release and pre-wetting
adjacent combustibles.


CONTROL VALVE - CORRECT ANSWER - A valve controlling flow to water-based
fire protection systems. Control valves do not include hose valves, inspector's test valves, drain
valves, trim valves for dry pipe, preaction and deluge valves, check valves, or relief valves.


OS&Y Valve - CORRECT ANSWER - (Outside Stem and Yoke valve) an indicating type
of control valve used for fire sprinkler system.


Curb Valve - CORRECT ANSWER - a non-indicating gate valve equipped with a cast
iron extension box flushed with a sidewalk with an operating nut of 1 1⁄4 inch, this valve is
operated using a special curb key wrench. This valve controls the municipal water supply serving
the fire sprinkler system.


CORROSION-RESISTANT SPRINKLER - CORRECT ANSWER - A sprinkler
fabricated with corrosion resistant materials, or special coatings to be used in an atmosphere that
would corrode standard sprinklers.


DEFICIENCY - CORRECT ANSWER - A condition in which the application of the
component is not within its designed limits or specifications.


CRITICAL DEFICIENCY - CORRECT ANSWER - A deficiency that, if not corrected,
can have an effect on the performance of the fire protection system.


NON CRITICAL DEFICIENCY - CORRECT ANSWER - A deficiency that does not
have an effect on the performance of the fire protection system, but correction is needed for the
proper inspection, testing, and maintenance of the system(s).

Document information

Uploaded on
April 30, 2025
Number of pages
10
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$11.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
STANFORDGENIUS
4.0
(236)
Sold
1559
Followers
108
Items
113323
Last sold
4 hours ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions