WITH ANSWERS GUARANTEE A+
✔✔What is PATRIOT prime power? - ✔✔150KW, 400Hz, 3 phase, 208/120 volts
✔✔True/False: When conducting PMCS, if a fault is found that can be corrected, the
operators should finish the remaining checks before correcting - ✔✔False
✔✔Passing underneath a mast while it is being stowed or erected is a _____ -
✔✔Warning
✔✔True/False: All personnel need to be licensed on their assigned equipment
regardless of crew position. - ✔✔True
✔✔To be Table IV certified, you must accomplish certain tasks at the battery and
battalion level. Circle all that apply - ✔✔Be licensed on your equipment, Be taught how
to complete proper PMCS, Attain a 90% or higher on the written examination
✔✔What is the radiation hazard zone of the RADAR? - ✔✔120 degrees in front of and
120 meters downrange of the PTL, 2 meters around
✔✔What is a class III leak? - ✔✔Leakage of fluid great enough to form drops that fall
from the item being checked/inspected
✔✔True/False: A broken or inoperable turn signal is considered a safety deadline -
✔✔True
✔✔Ground guides are required when - ✔✔when vehicles are backed or when moved in
an assembly area or motor pool
✔✔True/False: When ground guiding a vehicle, the SM at the rear of the vehicle will
provide movement signals directly to the driver - ✔✔False
✔✔What must be removed during RS emplacement to ensure that you do not destroy
the comparator window? - ✔✔Comparator Travel Cover
✔✔True/False: AMG operators can open hydraulic bleed plugs if masts are stuck in
order to lower them - ✔✔False
✔✔Name 3 types of hazards to personnel on the EPP III that are specifically outlined in
44-CW-D0017 - ✔✔Shocks, Burns, Noise
, ✔✔Operation of the EPP III with a Class I or II leak is allowable, except for ______
leaks - ✔✔Fuel
✔✔True/False: A broken or missing stop lock on the EPP power cable reel always
renders the equipment NMC - ✔✔False
✔✔How are the masts of the AMG erected? - ✔✔Hydraulically
✔✔How are the masts of the AMG extended? - ✔✔Pneumatically
✔✔What is the approximate maximum height of the AMG masts, platform to top? -
✔✔81 feet
✔✔During emplacement when will time start for the EPP crew drill? - ✔✔When the
vehicle is oriented and halted
✔✔What is the maximum load on the AMG antenna protective covers? - ✔✔600 lbs
✔✔How many outriggers on the RS must have contact with the ground when
emplaced? - ✔✔4
✔✔What is the minimum number of people required to emplace the Radar Shroud? -
✔✔2
✔✔How many minutes should you allow the EPP generators to cool down for after
disconnecting AC power? - ✔✔5 minutes
✔✔If the EPP generator does not start within 20 seconds, how long should you wait
before repeating the starting procedure? - ✔✔30 seconds
✔✔How long does the radar crew have to emplace the system? - ✔✔45 minutes
✔✔How often should you empty the AMG mast air tanks? - ✔✔Daily
✔✔True/False: AMVs, except nontactical vehicles, will be equipped with properly sized
chock blocks for use when parked on sloped terrain, while maintenance is being
performed, or when a vehicle is parked and a trailer is attached - ✔✔True
✔✔True/False: Head protection (combat vehicle crew, approved ballistic helmet, or
flight helmet as appropriate) will be worn by all personnel operating or riding as a
passenger in Army tactical vehicles in the field. Commanders at company, troop, and
battery level may determine the headgear worn in garrison - ✔✔True