1



RAC Practice Exam 2025|Actual Exam Test(MULTIPLE
CHOICES) and (RATIONALES) questions and verified
answers |GET IT 100% ACCURATE!!
A physician reports to a manufacturer that a patient was hospitalized with acute
sepsis after treatment with an approved device. This side effect is not listed in the
package insert. This event must be reported by the manufacturer to FDA no later
than:



A. 5 calendar days.

B. 15 calendar days.

C. 30 calendar days.

D. The next quarterly or annual report. - (answers)C. 30 calendar days.



Serious injury must be reported within 30 days. 21 CFR 803.50(a).



Under the IDE regulation, all of the following must be reported to the sponsor
within five working days EXCEPT:



A. A deviation from the investigational plan.

B. Withdrawal of IRB approval.

C. An unanticipated adverse device effect.

D. Use of a device without informed consent. - (answers)C. An unanticipated
adverse device effect.

, 2


The investigator notifies the sponsor and IRB within 10 days of notification of any
unanticipated adverse effect. 21 CFR 812.150.



When design verification testing is being performed by a manufacturer, which
element is NOT included as a potential requirement under device design
verification section of the QSR?



A. Identification of the design.

B. Software validation.

C. Identification of test methods used.

D. Name of individuals performing the testing. - (answers)C. Identification of test
methods used.



Refer to 820.30(f)



Under the statutory violations, lack of an approved PMA for a PMA device that is
not exempt and is in commercial distribution is considered to be:



A. Adulteration

B. Improper use

C. Misbranded

D. Fraudulent - (answers)A. Adulteration

, 3


PMA products introduced into commercial distribution without an approval PMA
are considered to be adulterated. FD&C Act 501(f).



A manufacturer of the following must file an IDE before conducting a human
clinical study?



A. A device in commercial distribution before 28 May 1976 when used or
investigated in accordance with its indications in labeling in effect at that time.

B. A device intended solely for veterinary use.

C. A custom device being studied for safety and effectiveness.

D. A device in commercial distribution before 28 May 1976 when used or
investigated in accordance with its indications in labeling in effect at that time.
And a device intended solely for veterinary use. - (answers)C. A custom device
being studied for safety and effectiveness.



While a custom device may be studied in humans without an IDE, if its safety and
efficacy are being studied in support of commercial marketing, an IDE must be
filed (21 CFR 812.2(c)(7)



The regulatory affairs professional performs all of the following prior to
submitting a PMA to FDA EXCEPT:



A. Preparing criteria for the MDR report.

B. Preparing a brief statement of reasons for noncompliance with regulation.

C. Identifying all omissions in PMA content.

, 4


D. Reviewing, organizing and checking adequacy of data pertaining to safety and
efficacy evaluation. - (answers)A. Preparing criteria for the MDR report.



MDR reporting is a post PMA approval requirement.



Which of the following sections is required in a PMA?



A. Patent certification information.

B. A copy of quality manual.

C. An economic cost/benefit assessment.

D. A discussion of benefit and risk considerations. - (answers)D. A discussion of
benefit and risk considerations.



See 21 CFR 814.20(b)(3)(vi).



Subacute toxicity testing should be performed:



A. In two rodent species.

B. In one rodent and one non-rodent species.

C. For a minimum of two weeks.

D. For a minimum of six months. - (answers)B. In one rodent and one non-rodent
species.

Document information

Uploaded on
April 14, 2025
Number of pages
56
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$21.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
DocBeast
4.9
(629)
Sold
10782
Followers
7
Items
2753
Last sold
3 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions