Comminutor - Answer-A __________________ does not remove solids from the
wastewater, it shreds them and passes them to the next process

Large debris - Answer-Screens are installed to remove ______________
___________ at the plant headworks

settle out - Answer-If wastewater is allowed to 'back up" behind a screen, organic
waste can ________ _______ and cause odor problems

break down - Answer-Grit is removed too since it does not ________ ________
during treatment and to prevent equipment damage in downstream processes

organic waste - Answer-A grit classifier separates and removes ________ ________
from the grit that has been removed from the grit channel

organic / low - Answer-_________ waste mixed with the grit indicates that flow
velocities are too ______ in the grit channel

Comminutor - Answer-A _______________ shreds solids and passes them along to
the next treatment process

burial - Answer-Grit is typically disposed of by _____ in a landfill

Hydrogen sulfide - Answer-____________ ____________ is a gas that smells like
rotten eggs, is heavier than air, dulls the sense of smell, is extremely toxic, and is
explosive at certain concentrations in air

heavy rainfall - Answer-Periods of ________ ________ will deliver wastewater with
high levels of grit in systems that experience infiltration and inflow in the collection
system

pumps / pipes and digesters - Answer-Grit is removed early in the treatment process
since it can damage ________, and cause problems in ________ and _______

30 degrees, 45 degrees - Answer-Trash racks (bar racks) are constructed of steel
bars spaced 2 to 6 inches apart, placed in a flow channel at an angle ranging from
____________ to ___________ from vertical

screens, racks - Answer-Bar _______ are similar to bar _______except the spacing
between the bars is smaller

0.75, 2 - Answer-Bar screen spacing ranges from ______ to ______ inches

,1 ft / sec - Answer-Flow through the grit channel should be approximately
____________

0.7 fps - 1.4 fps - Answer-The normal range of grit channel flow is ____ fps to ____
fps to keep organic material suspended while allowing the grit to settle

remove - Answer-The purpose of a grit classifier is to ______ organic material from
the grit

volume and weight - Answer-A screening press reduces the ______ and _____ of
screening waste sent to the landfill since it dewaters and compacts screening waste

organic - Answer-Fine screens collect more _______ waste than larger, more coarse
screens, which can cause odor problems

15 minutes - Answer-Lab analysis of pH, temperature and dissolved oxygen should
be performed within ______ minutes of samples collection since they can change
rapidly once collected

2 pH units - Answer-pH buffers used for pH meter calibration should bracket the
expected pH and be at least ______pH units apart

Winkler - Answer-Dissolved oxygen can be determined by the Azide modification of
the ___________titration method

8 hours - Answer-When preserved with Sulfuric acid, a sample collected for
dissolved oxygen can wait up to ______ hour(s) before analysis when using the
Winkler method

0 and 4 - Answer-Samples collected for BOD analysis can be preserved by
refrigerating between ____ and _____ degrees Celsius

2 days - Answer-Preserved BOD samples can be held for ____ days

BOD - Answer-_______ samples are generally not used for process control since the
test takes 5 days to complete

7 days - Answer-Samples collected for suspended solids can be preserved and held
for ______ days before analysis

beaker - Answer-A ______ is used in the laboratory for measuring approximate
volumes and mixing chemicals

graduated cylinder - Answer-A _____________ ___________ can be used to quickly
measure and pour various liquid volumes

immediately - Answer-Chlorine residual should be analyzed ___________after
sample collection

,Pipette - Answer-A ___________ is used to accurately measure small volumes of
liquid

Grit - Answer-______ is composed of primarily inorganic material that does not
decompose during the biological treatment process

Inorganic / organic - Answer-Heavier ____________ material will settle in the grit
channel while the lighter __________material will pass on to the primary clarifier for
settling

break down - Answer-Grit is removed since it will not _______________ in the
anaerobic digester

equipment damage - Answer-Grit is removed to prevent _____________
____________ in downstream processes

solids and floatables - Answer-The primary treatment process is designed to
separate ________ and ________ from wastewater

50% - Answer-The primary treatment process can remove up to _______ of
incoming BOD when chemical coagulants are used

Colloidal particles - Answer-_______ ________ are very small and tend to carry an
electrical charge which makes it very difficult for them to flocculate and settle out

coagulants - Answer-____________ can be used to neutralize the electrical charge
of the colloidal particles and enable them to flock together and increase in size so
that they too will settle out

surface, hydraulic - Answer-The two main parameters an operator should use to
ensure proper settling occurs in the primary clarifier are the _________ overflow rate
and the __________ retention time

below, below - Answer-Grease removal from wastewater with a pH ________7 is
more difficult since grease tends to remain in suspension if the wastewater pH is
_______7

50% and 65% - Answer-Without chemical addition, the primary clarification process
can achieve between _____ and _____ suspended solid removal

25% and 35% - Answer-Without chemical addition, the primary clarification process
can achieve between _____ and _____ BOD reduction

4% to 6% - Answer-If primary sludge is sent directly to an anaerobic digestion
process, the operator will want the sludge pumped to have a ______ to _______
total solids concentration

600-800 gpd/sq ft - Answer-A typical surface overflow rate range for a primary
clarifier receiving raw wastewater as well as the plant's waste activated sludge is
_____ - _____ gpd/sq ft

, total solids - Answer-70 - 80% of primary sludge ______ ______ are usually volatile

aerating - Answer-By __________ the wastewater prior to primary clarification,
grease in the wastewater will be easier to remove

annually - Answer-Primary clarifiers should be drained and inspected __________

phosphorous - Answer-Primary sludge fermentation is used in plants that are
required to remove ______________ from the wastewater

3 to 5 - Answer-Sludge will ferment and produce volatile fatty acids to aid with
phosphorous removal when allowed to accumulate for ______ to _____ days in a
clarifier

chemicals / solids and BOD - Answer-Enhanced primary treatment using _______ to
achieve better ________ and ________ removals from the clarification process

Uniform Size - Answer-Trickling filter media should be of _________ __________ to
allow adequate ventilation

lowest - Answer-Trickling filter operators should use the __________recirculation
rate possible that produces good effluent quality

increase - Answer-Water temperatures _________the biological activity of a trickling
filter zoogloeal mass leading to better treatment

Slime growth / ventilation - Answer-The purpose of trickling filter media is to provide
a surface for _______ _______ to develop and allow for adequate _____________

Roughing - Answer-A trickling filter can be used as a ___________ filter to reduce
the organic load of the wastewater prior to another biological process

underdrain - Answer-The _________ channel should be drained during periods of
trickling filter shutdown to prevent odors and insect problems from developing

Increasing - Answer-_______________ the recirculation rate will help to reduce the
effluent BOD from a trickling filter

hydraulic - Answer-Recirculation of the trickling filter effluent is done to maintain a
constant __________ load on the trickling filter

low / reduced - Answer-If the recirculation rate is too ____ in a trickling filter, it can
lead to _____BOD removal, ponding, and filter fly reproduction

orifice/ stay rod - Answer-Adjusting the distributor arm ______openings and the
_____ _____ turnbuckles may be necessary to ensure even distribution of
wastewater over the surface of a trickling filter

Document information

Uploaded on
April 13, 2025
Number of pages
31
Written in
2024/2025
Type
Exam (elaborations)
Contains
Unknown
$22.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
biggdreamer
4.0
(48)
Sold
300
Followers
67
Items
18337
Last sold
2 weeks ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions