Sprinkler System S-12
2nd Notification for Fire Department - ANS -the work or repairs cannot be completed and the system restored to service
within 8 hours of the time the system was placed or went out of service
\3rd Notification for Fire Department - ANS -With respect to a fire alarm system, the work or repairs will require the fire
alarm system to be out of service for more than 8 hours in any 24 hour period
\4th Notification for Fire Department - ANS -One or more other fire protection systems in the area in which a fire protection
system is out of service are or will also be out of service at the same time.
\A CCTV camera that is stalled inside a shell that resembles a sprinkler head is an example of... - ANS -A device similar
to fire protection equipment
\A sprinkler system - ANS -is a fire extinguishing system, that utilizes water as the extinguishing agent
\A supply of at least ______ extra sprinkler heads shall be kept available on the premises, to replace promptly any fused
or damaged sprinklers - ANS -Six
\Any head which has opened or has been damaged shall be replaced immediately with sprinkler head of similar
characteristics such as? - ANS -Operating temperature, orifice size, deflector orientation and thermal sensitivity
\At least once every______, the fire department connection for a sprinkler system shall be subjected to a hydro static
pressure test to demonstrate its suitability. - ANS -5 years
\Bronx Telephone Number - ANS -718-430-0200
\Brooklyn Telephone Number - ANS -718-965-8300
\By competent authority holding a S-12 certificate - ANS -Automatic and non automatic sprinkler systems shall be
inspected, tested, and maintenance
\detailed records - ANS -shall include information relative to conditions of water supply, gravity, and pressure tanks, levels
therein, valves, risers, piping, sprinkler heads. record shall be READILY AVAILABLE to any representative
\Drain test results - ANS -shall be posted on the tag indicating both the static and flow pressures before and after the
system was placed in an out of service condition
\Email - ANS -
, New York City Fire Department
Bureau of Fire Prevention
Fire Suppression Unit 3rd floor
9 Metro Tech Center
Brooklyn, NY 11201
\Fire Department notifications for out of service conditions - ANS -notification that a sprinkler system or fire alarm system,
or any part thereof, is or will be out of service shall be made to the fire department
\Fire guard - ANS -Under 50,000 the impairment coordinator can act as guard for the first 4 hours.
Greater than 50,000 guard required for every 50,000 thereafter
\Identifying OOS systems using discs/tags - ANS -Systems that are out of service shall be immediately identified by
placing a tag at each of the following locations: Fire department connections, system control valves, fire command center
or other clearly visible location in the lobby of the building
\If no impairment is found in the entire system green tags will be placed on the ________ ___________ __________ -
ANS -Main control valve
\Impaired equipment - ANS -underground service mains, water storage tanks, fire department connections, control valves,
fire and or booster pumps, that are out of service and are considered vital to part of the system that are required to be
tagged
\Impairment Coordinator - ANS -The person responsible for ensuring that proper safety precautions are taken when a fire
protection system is placed out of service. The building owner shall assign an impairment coordinator to comply with the
requirements of this section. In the absence of a specific designee, the owner shall be considered the impairment
coordinator.
\Manhattan Telephone Number - ANS -212-570-4300
\Master Plumber - ANS -is limited to residential occupies 30 sprinkler heads or less without a booster jump,
\Minor defect - ANS -If it is not corrected within 30 days it shall be deemed to be an impairment and reported in writing to
FD.
\National Fire Protection Association - ANS -What does NFPA stand for? Personally supervise inspection, testing,
servicing and maintenance of sprinkler systems
\Notification for Fire Department - ANS -Notification for Fire Department The sprinkler system or fire alarm system is or
will be out of service on more than one floor or building
2nd Notification for Fire Department - ANS -the work or repairs cannot be completed and the system restored to service
within 8 hours of the time the system was placed or went out of service
\3rd Notification for Fire Department - ANS -With respect to a fire alarm system, the work or repairs will require the fire
alarm system to be out of service for more than 8 hours in any 24 hour period
\4th Notification for Fire Department - ANS -One or more other fire protection systems in the area in which a fire protection
system is out of service are or will also be out of service at the same time.
\A CCTV camera that is stalled inside a shell that resembles a sprinkler head is an example of... - ANS -A device similar
to fire protection equipment
\A sprinkler system - ANS -is a fire extinguishing system, that utilizes water as the extinguishing agent
\A supply of at least ______ extra sprinkler heads shall be kept available on the premises, to replace promptly any fused
or damaged sprinklers - ANS -Six
\Any head which has opened or has been damaged shall be replaced immediately with sprinkler head of similar
characteristics such as? - ANS -Operating temperature, orifice size, deflector orientation and thermal sensitivity
\At least once every______, the fire department connection for a sprinkler system shall be subjected to a hydro static
pressure test to demonstrate its suitability. - ANS -5 years
\Bronx Telephone Number - ANS -718-430-0200
\Brooklyn Telephone Number - ANS -718-965-8300
\By competent authority holding a S-12 certificate - ANS -Automatic and non automatic sprinkler systems shall be
inspected, tested, and maintenance
\detailed records - ANS -shall include information relative to conditions of water supply, gravity, and pressure tanks, levels
therein, valves, risers, piping, sprinkler heads. record shall be READILY AVAILABLE to any representative
\Drain test results - ANS -shall be posted on the tag indicating both the static and flow pressures before and after the
system was placed in an out of service condition
\Email - ANS -
, New York City Fire Department
Bureau of Fire Prevention
Fire Suppression Unit 3rd floor
9 Metro Tech Center
Brooklyn, NY 11201
\Fire Department notifications for out of service conditions - ANS -notification that a sprinkler system or fire alarm system,
or any part thereof, is or will be out of service shall be made to the fire department
\Fire guard - ANS -Under 50,000 the impairment coordinator can act as guard for the first 4 hours.
Greater than 50,000 guard required for every 50,000 thereafter
\Identifying OOS systems using discs/tags - ANS -Systems that are out of service shall be immediately identified by
placing a tag at each of the following locations: Fire department connections, system control valves, fire command center
or other clearly visible location in the lobby of the building
\If no impairment is found in the entire system green tags will be placed on the ________ ___________ __________ -
ANS -Main control valve
\Impaired equipment - ANS -underground service mains, water storage tanks, fire department connections, control valves,
fire and or booster pumps, that are out of service and are considered vital to part of the system that are required to be
tagged
\Impairment Coordinator - ANS -The person responsible for ensuring that proper safety precautions are taken when a fire
protection system is placed out of service. The building owner shall assign an impairment coordinator to comply with the
requirements of this section. In the absence of a specific designee, the owner shall be considered the impairment
coordinator.
\Manhattan Telephone Number - ANS -212-570-4300
\Master Plumber - ANS -is limited to residential occupies 30 sprinkler heads or less without a booster jump,
\Minor defect - ANS -If it is not corrected within 30 days it shall be deemed to be an impairment and reported in writing to
FD.
\National Fire Protection Association - ANS -What does NFPA stand for? Personally supervise inspection, testing,
servicing and maintenance of sprinkler systems
\Notification for Fire Department - ANS -Notification for Fire Department The sprinkler system or fire alarm system is or
will be out of service on more than one floor or building