EPA 608 TYPE II TEST (2025) EXAM QUESTIONS WITH COMPLETE
SOLUTIONS GUARANTEED PASS BRAND NEW 2025
Describe ways you can visually look for leaks.
a. Using soap bubbles
b. Looking for traces of oil
c. Excessive superheat, caused by low refrigerant charge
d. All the above - CORRECT ANSWER - >d. All the above
Type II classification, as identified by EPA, applies to what equipment?
a. Small appliances with five (5) pounds of refrigerant or less
b. Refrigerators, freezers, and vending machine appliances
c. Low pressure appliances
d. Split air conditioning equipment with five (5) pounds of refrigerant
or more - CORRECT ANSWER - >d. Split air conditioning equipment with
five (5) pounds of refrigerant
or more
What are the leak repair requirements for comfort cooling appliances
and commercial Appliances containing 50 lbs. or more of refrigerant?
a. Must be repaired if leak rate exceeds 15% in comfort cooling
appliances.
b. Must be repaired if leak rate exceeds 35% in all commercial and
industrial
process refrigeration\
c. a and b
d. None of the above - CORRECT ANSWER - >c. a and b
, What type of refrigerant was the most common before outlawing CFCs
and
HCFCs?
a. R-12
b. R-22
c. R-500
d. R-134A - CORRECT ANSWER - >b. R-22
The required level of evacuation for recovery equipment manufactured
after
November 15, 1993, on a system containing less than 200 pounds of R-
12
refrigerant is:
a. 0 inches Hg
b. 4 inches Hg
c. 10 inches Hg
d. 15 inches Hg - CORRECT ANSWER - >c. 10 inches Hg
What is the purpose of the filter drier and when should it be changed?
a. To filter the oil. Change every year.
b. To remove moisture from the refrigerant, replace on a routine basis
or anytime a system is opened
c. Cleans the air. Replace monthly
d. Dryer's air filters. Replace yearly - CORRECT ANSWER - >b. To remove
moisture from the refrigerant, replace on a routine basis or anytime a
system is opened
Industrial process and commercial refrigeration equipment with over
50 pounds
of refrigerant with an annual leak rate of ___ % requires repair under
EPA
regulations.
a. 0
SOLUTIONS GUARANTEED PASS BRAND NEW 2025
Describe ways you can visually look for leaks.
a. Using soap bubbles
b. Looking for traces of oil
c. Excessive superheat, caused by low refrigerant charge
d. All the above - CORRECT ANSWER - >d. All the above
Type II classification, as identified by EPA, applies to what equipment?
a. Small appliances with five (5) pounds of refrigerant or less
b. Refrigerators, freezers, and vending machine appliances
c. Low pressure appliances
d. Split air conditioning equipment with five (5) pounds of refrigerant
or more - CORRECT ANSWER - >d. Split air conditioning equipment with
five (5) pounds of refrigerant
or more
What are the leak repair requirements for comfort cooling appliances
and commercial Appliances containing 50 lbs. or more of refrigerant?
a. Must be repaired if leak rate exceeds 15% in comfort cooling
appliances.
b. Must be repaired if leak rate exceeds 35% in all commercial and
industrial
process refrigeration\
c. a and b
d. None of the above - CORRECT ANSWER - >c. a and b
, What type of refrigerant was the most common before outlawing CFCs
and
HCFCs?
a. R-12
b. R-22
c. R-500
d. R-134A - CORRECT ANSWER - >b. R-22
The required level of evacuation for recovery equipment manufactured
after
November 15, 1993, on a system containing less than 200 pounds of R-
12
refrigerant is:
a. 0 inches Hg
b. 4 inches Hg
c. 10 inches Hg
d. 15 inches Hg - CORRECT ANSWER - >c. 10 inches Hg
What is the purpose of the filter drier and when should it be changed?
a. To filter the oil. Change every year.
b. To remove moisture from the refrigerant, replace on a routine basis
or anytime a system is opened
c. Cleans the air. Replace monthly
d. Dryer's air filters. Replace yearly - CORRECT ANSWER - >b. To remove
moisture from the refrigerant, replace on a routine basis or anytime a
system is opened
Industrial process and commercial refrigeration equipment with over
50 pounds
of refrigerant with an annual leak rate of ___ % requires repair under
EPA
regulations.
a. 0