Motor Control Exam Questions and Answers 100% Solved Define Full Load Current or FLA - Answers nameplate current when motor is running Define Starting Current or inrush current - Answers the current that is drawn by starting the motor Define Rotor - Answers rotating portion of an ac motor define Locked rotor current - Answers current drawn from line when rotor is jammed define Contactor - Answers device used to establish or interrupt a power circuit. no olr protection define HP rated - Answers able to establish or interrupt motor full load current define Overload Relay - Answers device that provides overload protection for motor only What are the main parts of a overload relay - Answers overload heater, contact and thermal connection Define Motor starter - Answers device rated to start a motor, it provides overload protection and can stop motor What does the motor starter consist of - Answers contacts and overload relay Define Combination starter - Answers a starter with a manual disconnection means built into the same enclosure Define Across the line starter - Answers starter designed to start motor with full line voltage define reduced voltage starter - Answers starter designed to start motor with reduced line voltage define Manual starter - Answers starter with contacts that must be manually opened and closed mechanically define Magnetic starter - Answers Starter with contacts that open and close electromagnetically define Normally Open - Answers in the de-energized state it is normally open define Normally Closed - Answers in the de-energized state it is normally closed define Auxiliary Contacts - Answers additional control contacts in addition to main contacts define Chatter - Answers noise in contacts, caused by attraction and release of the armature by the electromagnetic coil define shading coil - Answers copper ring around part of the contacts magnetic face that is used to prevent chatter and premature wear to contacts define Blow out coil - Answers electromagnetic coil that deflects and defuses arc that may occur when circuit is interrupted define power circuit - Answers carries the power from the line to motor define Control Circuit - Answers carries signals either electrical or mechanical to control devices define Low voltage release - Answers on failure of supply voltage the motor restarts automatically. define 2 wire control - Answers low voltage release define low voltage protection - Answers on failure of power supply and return of power, it must be manually restart before it can be turned on again define Maintain Contact or Seal in contact - Answers contacts that are in parallel with the start button which keeps coil energized after push button has been released define Schematic diagram - Answers shows components in their electrical relationship, not physical location. best for trouble shooting define Wiring Diagram - Answers Shows components mounted in their general locations and their physical relationship define Jogging - Answers moving machine with short jabs that are quickly repeated of opening and closing circuit define Control Relay - Answers similar to contacts, used to control circuit components define interlock - Answers can be electrical or mechanical. is a safety to prevent from two operations happening at the same time define plugging - Answers rapid stop or braking of motor by reversing the phase sequence of a 3 phase motor define service factor - Answers rating factor that can be applied to FLA define Insulation Code - Answers this indicates the ambient temperature the motor is rated to run in What are the three types of common manual motor starters - Answers Drum, toggle, push button List three significant rating found on manual motor starters - Answers Volts, amps and Horsepower What are the different ratings for the drum switch - Answers 120V=1.5HP and 240V=3HP

Content preview

Motor Control Exam Questions and Answers 100% Solved

Define Full Load Current or FLA - Answers nameplate current when motor is running

Define Starting Current or inrush current - Answers the current that is drawn by starting the motor

Define Rotor - Answers rotating portion of an ac motor

define Locked rotor current - Answers current drawn from line when rotor is jammed

define Contactor - Answers device used to establish or interrupt a power circuit. no olr protection

define HP rated - Answers able to establish or interrupt motor full load current

define Overload Relay - Answers device that provides overload protection for motor only

What are the main parts of a overload relay - Answers overload heater, contact and thermal connection

Define Motor starter - Answers device rated to start a motor, it provides overload protection and can
stop motor

What does the motor starter consist of - Answers contacts and overload relay

Define Combination starter - Answers a starter with a manual disconnection means built into the same
enclosure

Define Across the line starter - Answers starter designed to start motor with full line voltage

define reduced voltage starter - Answers starter designed to start motor with reduced line voltage

define Manual starter - Answers starter with contacts that must be manually opened and closed
mechanically

define Magnetic starter - Answers Starter with contacts that open and close electromagnetically

define Normally Open - Answers in the de-energized state it is normally open

define Normally Closed - Answers in the de-energized state it is normally closed

define Auxiliary Contacts - Answers additional control contacts in addition to main contacts

define Chatter - Answers noise in contacts, caused by attraction and release of the armature by the
electromagnetic coil

define shading coil - Answers copper ring around part of the contacts magnetic face that is used to
prevent chatter and premature wear to contacts

define Blow out coil - Answers electromagnetic coil that deflects and defuses arc that may occur when
circuit is interrupted

, define power circuit - Answers carries the power from the line to motor

define Control Circuit - Answers carries signals either electrical or mechanical to control devices

define Low voltage release - Answers on failure of supply voltage the motor restarts automatically.

define 2 wire control - Answers low voltage release

define low voltage protection - Answers on failure of power supply and return of power, it must be
manually restart before it can be turned on again

define Maintain Contact or Seal in contact - Answers contacts that are in parallel with the start button
which keeps coil energized after push button has been released

define Schematic diagram - Answers shows components in their electrical relationship, not physical
location. best for trouble shooting

define Wiring Diagram - Answers Shows components mounted in their general locations and their
physical relationship

define Jogging - Answers moving machine with short jabs that are quickly repeated of opening and
closing circuit

define Control Relay - Answers similar to contacts, used to control circuit components

define interlock - Answers can be electrical or mechanical. is a safety to prevent from two operations
happening at the same time

define plugging - Answers rapid stop or braking of motor by reversing the phase sequence of a 3 phase
motor

define service factor - Answers rating factor that can be applied to FLA

define Insulation Code - Answers this indicates the ambient temperature the motor is rated to run in

What are the three types of common manual motor starters - Answers Drum, toggle, push button

List three significant rating found on manual motor starters - Answers Volts, amps and Horsepower

What are the different ratings for the drum switch - Answers 120V=1.5HP and 240V=3HP

What are the different ratings of HP for the common starters - Answers Toggle is 1HP, push button is
5HP and drum is 1.5-3HP

What is the difference of a single phase toggle switch and single pole light switch - Answers The toggle
switch has HP, voltage and amp ratings and also hp rated contacts. Is also able to interrupt locked rotor
current

Document information

Uploaded on
April 9, 2025
Number of pages
6
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$10.89

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TutorJosh
3.5
(76)
Sold
502
Followers
16
Items
32970
Last sold
1 day ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions