Which AFI states that aircrew will use supplemental oxygen anytime the cabin altitude exceeds 10,000 feet MSL? - Correct Ans-AFI 11-202 vol 3 What color cylinder is low pressure oxygen stored in? - Correct Ans-Yellow What color cylinder is high pressure oxygen stored in? - Correct Ans-Green At what PSI are low pressure cylinders considered full? - Correct Ans-425 +/- 25 psi At what PSI are high pressure cylinders considered full? - Correct Ans- psi At what PSI are low pressure cylinders considered empty? - Correct Ans-Operational: 100 psi Maintenance: 50 psi At what PSI are high pressure cylinders considered empty? - Correct Ans-Operational: 200 psi Maintenance: 100 psi In what unit is LOX measured? When is LOX considered full? Empty? - Correct Ans-Liters Full: 95% Empty: 10% One unit of liquid oxygen yields about _________ units of gaseous oxygen - Correct Ans-860 Low pressure LOX systems are usually found on what type of aircraft? What is the approximate line pressure? - Correct Ans-single/dual seat aircraft 70-90 psi AETC 50-120 psi USAF High-pressure LOX systems are usually found on what type of aircraft? What is the approximate line pressure? - Correct Ans-Multi-place aircraft 300 psi Solid state oxygen systems provide emergency oxygen via a _____________? For how long? - Correct Ans-chemical reaction 15 minutes What causes the chemical reaction in a solid state PBE or EEBD? - Correct Ans-sodium chlorate candle Users of a solid state oxygen system may detect a harmless amount of ____________ for about the first __________ seconds. - Correct Ans-chlorine 12 What does OBOGS stand for? - Correct Ans-On Board Oxygen Generating System In an OBOGS, Oxygen is extracted from engine bleed air through a ______________________. - Correct Ans-molecular sieve What type of oxygen system is utilized in the T-6? - Correct Ans-OBOGS In the event of an OBOGS failure the _____________ will supply approximately ___________________ of oxygen - Correct Ans-plenum 1 breath What two types of oxygen delivery systems are used in today's aircraft? - Correct Ans-Continuous flow Pressure demand With the exception of the oxygen generating system, each type of oxygen delivery system can be provided in a _________________ or a __________________ system - Correct Ans-fixed system (aircraft mounted) portable system (walk-around bottle) What is the transition altitude in the US? - Correct Ans-18,000 MSL The _____________ level is the altitude where the crew member selects an altimeter setting of _____________ during climb out and returns the altimeter to the __________ setting on descent. - Correct Ans-transition 29.92 local In a ________________ system, the regulator delivers continuously regardless of demand. - Correct Ans-continuous flow The emergency oxygen cylinder found in the ejection seat is a _____________________ system for emergency use up to ____________. - Correct Ans-continuous flow FL500 What is the operational and emergency ceiling for common continuous flow oxygen systems? - Correct Ans-FL250 op / FL300 emer In order for high-performance aircraft to operate at high altitudes (FL400), __________________ is insufficient to maintain normal levels of blood oxygen saturations. _________________ breathing is necessary to increase the lung pressure above the atmospheric pressure. - Correct Ans-100% oxygen Positive pressure The regulators used in a positive pressure system are different from _____________ demand system regulators, but function much the same until the ______________ feature is activated. - Correct Ans-diluter positive pressure _______________ regulators are the most widely used automatic pressure demand regulators in modern aircraft. - Correct Ans-Narrow panel The pressure demand system has an operational ceiling of _____________ and an emergency ceiling of _______________. - Correct Ans-FL430 FL500 What 3 components make up the fire triangle? - Correct Ans-Oxygen Heat Fuel Where is the oxygen regulator installed in the T-6 cockpit? - Correct Ans-Right side console What are three common regulators associated with pressure demand systems? - Correct Ans-CRU-68/A CRU-69/A CRU-73/A In the T-6, O2 concentration with the lever in NORMAL position will range from _________ to _________ for altitude from sea level to 15,000 MSL. - Correct Ans-25% to 70% In the T-6, O2 concentration with the lever in NORMAL position will range from _________ to _________ for altitude from 15,000 MSL to 31,000 MSL. - Correct Ans-45% to 95% In the T-6, with the lever in MAX position what is the O2 concentration? - Correct Ans-95% The _______________ light illuminates any time either concentration lever is in the MAX position - Correct Ans-maximum concentration The OBOGS regulator provides slight ______________ continuously while the supply lever is in the ON position. - Correct Ans-positive pressure The ____________ has two positions, placarded "ON" and "OFF" - Correct Ans-supply lever T or F? If the supply lever for either regulator, front or back seat, is on the OBOGS system is operative and can run down the battery. - Correct Ans-True The _____________ has two positions, placarded "NORMAL" and "MAX" - Correct Ans-concentration lever When the concentration lever is set to "MAX" the regulator directs the OBOGS concentrator to supply ________________. - Correct Ans-the highest possible O2 concentration The _____________ has three positions placarded, respectively, "EMERGENCY," "NORMAL," and "TEST MASK" - Correct Ans-pressure lever When the pressure lever is in the "EMERGENCY" position O2 is supplied with _______________ amount of water pressure and in the "TEST MASK" position O2 is supplied with ___________ amount of water pressure. - Correct Ans-2" 16" The built in test (BIT) button activates the initiated OBOGS BIT (I-BIT) any time after __________ and the ____________ warm-up. - Correct Ans-engine start 3 minute The I-BIT provides verification that the _________ and ___________ are operating properly. - Correct Ans-OBOGS sensor OBOGS FAIL annunciator During the I-BITthe "OBOGS FAIL" annunciator should extinguish within ______________. - Correct Ans-2 minutes What 3 things does the flow indicator tell you? - Correct Ans-1. If you have good flow 2. If you have a leak 3. If you are hyperventilating What do the colors of the flow indicator mean? - Correct Ans-Black = no flow (holding breath/exhale) White = flow (inhale) The T-6A OBOGS bleed air is tapped from a port on the ____________ side of the engine. - Correct Ans-left Where is the OBOGS unit located? - Correct Ans-Fuselage right side avionics bay Where does the OBOGS get oxygen? - Correct Ans-Extracts it from the engine bleed air T or F? A concentrator in the OBOGS unit automatically adjusts the oxygen concentration for the current altitude based on the current cockpit pressure. - Correct Ans-True The ____________ functions as a holding tank between the OBOGS unit and the regulators. - Correct Ans-plenum The emergency oxygen system in the T-6 is a _____________ pressure gas, _______________ flow system. - Correct Ans-high continuous The emergency O2 bottle in the T-6 provides 100% O2 for the first ___________ to ____________ minutes. After that the CRU-60/P (if ship supply hose is disconnected) mixes an increasing amount of ____________ until the bottle is depleted. - Correct Ans-2 to 4 ambient air What is the normal pressure (black band) on the T-6 emergency O2 cylinder? - Correct Ans- psi How long does the emergency O2 cylinder on the T-6 last? - Correct Ans-8 to 10 minutes T or F? Ejection automatically starts the positive flow of oxygen to the crew member. - Correct Ans-True What manually activates the emergency O2 bottle and where is it located? - Correct Ans-green control loop on the left side of each seat T or F? Pulling the green ring a second time will deactivate the emergency O2 bottle? - Correct Ans-False. Once activated the cylinder cannot be shut off until depletion. Air Force aircrews use the ________________ helmet. - Correct Ans-HGU-55/P What functions does the HGU-55/P provide? - Correct Ans-Protection from head injury and ambient noise mounting for the visor and oxygen mask communications T or F? The basic functions of the MBU-12/P mask and the MBU-20A/P mask are the same? - Correct Ans-True The MBU-series masks are designed for ____________ oxygen systems. - Correct Ans-pressure demand What is the main physical difference between th

Content preview

Aircrew



UPT Aircrew Flight Equipment Detailed
Exam 2025

Which AFI states that aircrew will use supplemental oxygen anytime the cabin altitude
exceeds 10,000 feet MSL? - Correct Ans-AFI 11-202 vol 3

What color cylinder is low pressure oxygen stored in? - Correct Ans-Yellow

What color cylinder is high pressure oxygen stored in? - Correct Ans-Green

At what PSI are low pressure cylinders considered full? - Correct Ans-425 +/- 25 psi

At what PSI are high pressure cylinders considered full? - Correct Ans-1800-2000 psi

At what PSI are low pressure cylinders considered empty? - Correct Ans-Operational:
100 psi
Maintenance: 50 psi

At what PSI are high pressure cylinders considered empty? - Correct Ans-Operational:
200 psi
Maintenance: 100 psi

In what unit is LOX measured? When is LOX considered full? Empty? - Correct Ans-
Liters
Full: 95%
Empty: 10%

One unit of liquid oxygen yields about _________ units of gaseous oxygen - Correct
Ans-860

Low pressure LOX systems are usually found on what type of aircraft? What is the
approximate line pressure? - Correct Ans-single/dual seat aircraft
70-90 psi AETC
50-120 psi USAF

High-pressure LOX systems are usually found on what type of aircraft? What is the
approximate line pressure? - Correct Ans-Multi-place aircraft
300 psi

Solid state oxygen systems provide emergency oxygen via a _____________? For how
long? - Correct Ans-chemical reaction
15 minutes


Aircrew

,Aircrew


What causes the chemical reaction in a solid state PBE or EEBD? - Correct Ans-sodium
chlorate candle

Users of a solid state oxygen system may detect a harmless amount of ____________
for about the first __________ seconds. - Correct Ans-chlorine
12

What does OBOGS stand for? - Correct Ans-On Board Oxygen Generating System

In an OBOGS, Oxygen is extracted from engine bleed air through a
______________________. - Correct Ans-molecular sieve

What type of oxygen system is utilized in the T-6? - Correct Ans-OBOGS

In the event of an OBOGS failure the _____________ will supply approximately
___________________ of oxygen - Correct Ans-plenum
1 breath

What two types of oxygen delivery systems are used in today's aircraft? - Correct Ans-
Continuous flow
Pressure demand

With the exception of the oxygen generating system, each type of oxygen delivery
system can be provided in a _________________ or a __________________ system -
Correct Ans-fixed system (aircraft mounted)
portable system (walk-around bottle)

What is the transition altitude in the US? - Correct Ans-18,000 MSL

The _____________ level is the altitude where the crew member selects an altimeter
setting of _____________ during climb out and returns the altimeter to the __________
setting on descent. - Correct Ans-transition
29.92
local

In a ________________ system, the regulator delivers continuously regardless of
demand. - Correct Ans-continuous flow

The emergency oxygen cylinder found in the ejection seat is a
_____________________ system for emergency use up to ____________. - Correct
Ans-continuous flow
FL500

What is the operational and emergency ceiling for common continuous flow oxygen
systems? - Correct Ans-FL250 op / FL300 emer



Aircrew

, Aircrew


In order for high-performance aircraft to operate at high altitudes (FL400),
__________________ is insufficient to maintain normal levels of blood oxygen
saturations. _________________ breathing is necessary to increase the lung pressure
above the atmospheric pressure. - Correct Ans-100% oxygen
Positive pressure

The regulators used in a positive pressure system are different from _____________
demand system regulators, but function much the same until the ______________
feature is activated. - Correct Ans-diluter
positive pressure

_______________ regulators are the most widely used automatic pressure demand
regulators in modern aircraft. - Correct Ans-Narrow panel

The pressure demand system has an operational ceiling of _____________ and an
emergency ceiling of _______________. - Correct Ans-FL430
FL500

What 3 components make up the fire triangle? - Correct Ans-Oxygen
Heat
Fuel

Where is the oxygen regulator installed in the T-6 cockpit? - Correct Ans-Right side
console

What are three common regulators associated with pressure demand systems? -
Correct Ans-CRU-68/A
CRU-69/A
CRU-73/A

In the T-6, O2 concentration with the lever in NORMAL position will range from
_________ to _________ for altitude from sea level to 15,000 MSL. - Correct Ans-25%
to 70%

In the T-6, O2 concentration with the lever in NORMAL position will range from
_________ to _________ for altitude from 15,000 MSL to 31,000 MSL. - Correct Ans-
45% to 95%

In the T-6, with the lever in MAX position what is the O2 concentration? - Correct Ans-
95%

The _______________ light illuminates any time either concentration lever is in the
MAX position - Correct Ans-maximum concentration

The OBOGS regulator provides slight ______________ continuously while the supply
lever is in the ON position. - Correct Ans-positive pressure

Aircrew

Document information

Uploaded on
April 8, 2025
Number of pages
21
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$16.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
AlexScorer
2.5
(2)
Sold
11
Followers
0
Items
1800
Last sold
2 weeks ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions