CNIM Instrumentation Exam Questions With Complete Solutions /A unit of resistance is symbolized by A- A B- ohms C- E D- micro - Answer-B- ohms The capacity to resolve amplitudes of 256 discrete steps would require an 8 bit A to D converter. This can be represented by: A- 8 B- 8/256 C- 256 D- 2^8 - Answer-D- 2^8 What is the minimum required bandpass for an EP system? A- 1 - 1000 Hz B- 0.1 ‐ 5000 Hz C- 30 ‐ 1500 Hz D- 1 Hz - 20 KHz - Answer-B- 0.1 ‐ 5000 Hz The gain of an amplifier, set to give an output signal of 1 volt for an input signal of 10 microV, is A- 100,000 B- 10,000 C- 100 D- 1,000 - Answer-A- 100,000 A 100 mS epoch is recorded with a 10 mS post ‐ stimulus triggering. Which of the following best describes the resulting sweep? A- A 100 mS sweep starting 10 mS after the stimulus B- A 90 mS sweep starting 10 mS after the stimulus C- A 100 mS sweep starting 10 mS prior to the stimulus D- A 110 mS sweep starting 10 mS prior to the stimulus - Answer-A- A 100 mS sweep starting 10 mS after the stimulus SSEP recordings typically require a bandpass of A- 1000 Hz to 5,000 Hz B- 30 Hz to 3,000 Hz C- 100 Hz to 1,000 Hz D- .5 Hz to 200 Hz - Answer-B- 30 Hz to 3,000 Hz To accurately represent the amplitude of an EP waveform, a match must be made between the A- dwell time and sampling rate B- signal size and the vertical capacity of the digitizer C- high‐frequency noise and smoothing operation of the instrument D- horizontal resolution and signal size - Answer-B- signal size and the vertical capacity of the digitizer In selecting the horizontal parameters of analysis, the A- sampling rate should be the equivalent of the highest frequency in the signal B- analysis period should be at least twice the Nyquist frequency C- sampling rate should be at least two times greater than the highest frequency in the signal D- analysis period should approach the Nyquist frequency - Answer-C- sampling rate should be at least two times greater than the highest frequency in the signal The assumption that responses of excessive amplitude are likely to contain artifact forms the basis for A- digital filtering B- artifact rejection C- dwell time D- digital averaging - Answer-B- artifact rejection In a differential amplifier used for intraoperative monitoring, the common mode rejection of in phase signals is typically A- 100:1 B- 5:1 C- 10,000:1 D- 500:1 - Answer-C- 10,000:1 A differential amplifier records A- the second half of the two inputs B- only the first two inputs C- the second half of the two inputs D- the difference between the two inputs - Answer-D- the difference between the two inputs The Nyquist frequency is: A- equal to the sampling rate B- 1/3 the highest frequency C- 1/2 the highest frequency D- twice as great as the highest frequency - Answer-D- twice as great as the highest

Content preview

CNIM Instrumentation Exam Questions With
Complete Solutions

/A unit of resistance is symbolized by
A- A
B- ohms
C- E
D- micro - Answer-B- ohms

The capacity to resolve amplitudes of 256 discrete steps would require an 8 bit A to D
converter. This can be represented by:
A- 8
B- 8/256
C- 256
D- 2^8 - Answer-D- 2^8

What is the minimum required bandpass for an EP system?
A- 1 - 1000 Hz
B- 0.1 ‐ 5000 Hz
C- 30 ‐ 1500 Hz
D- 1 Hz - 20 KHz - Answer-B- 0.1 ‐ 5000 Hz

The gain of an amplifier, set to give an output signal of 1 volt for an input signal of 10
microV, is
A- 100,000
B- 10,000
C- 100
D- 1,000 - Answer-A- 100,000

A 100 mS epoch is recorded with a 10 mS post ‐ stimulus triggering. Which of the
following best describes the resulting sweep?
A- A 100 mS sweep starting 10 mS after the stimulus
B- A 90 mS sweep starting 10 mS after the stimulus
C- A 100 mS sweep starting 10 mS prior to the stimulus
D- A 110 mS sweep starting 10 mS prior to the stimulus - Answer-A- A 100 mS sweep
starting 10 mS after the stimulus

SSEP recordings typically require a bandpass of
A- 1000 Hz to 5,000 Hz
B- 30 Hz to 3,000 Hz
C- 100 Hz to 1,000 Hz
D- .5 Hz to 200 Hz - Answer-B- 30 Hz to 3,000 Hz

, To accurately represent the amplitude of an EP waveform, a match must be made
between the
A- dwell time and sampling rate
B- signal size and the vertical capacity of the digitizer
C- high‐frequency noise and smoothing operation of the instrument
D- horizontal resolution and signal size - Answer-B- signal size and the vertical capacity
of the digitizer

In selecting the horizontal parameters of analysis, the
A- sampling rate should be the equivalent of the highest frequency in the signal
B- analysis period should be at least twice the Nyquist frequency
C- sampling rate should be at least two times greater than the highest frequency in the
signal
D- analysis period should approach the Nyquist frequency - Answer-C- sampling rate
should be at least two times greater than the highest frequency in the signal

The assumption that responses of excessive amplitude are likely to contain artifact
forms the basis for
A- digital filtering
B- artifact rejection
C- dwell time
D- digital averaging - Answer-B- artifact rejection

In a differential amplifier used for intraoperative monitoring, the common mode rejection
of in phase signals is typically
A- 100:1
B- 5:1
C- 10,000:1
D- 500:1 - Answer-C- 10,000:1

A differential amplifier records
A- the second half of the two inputs
B- only the first two inputs
C- the second half of the two inputs
D- the difference between the two inputs - Answer-D- the difference between the two
inputs

The Nyquist frequency is:
A- equal to the sampling rate
B- 1/3 the highest frequency
C- 1/2 the highest frequency
D- twice as great as the highest frequency - Answer-D- twice as great as the highest
frequency

The following are examples of good insulating materials, inhibiting current flow:
A- silicon and germanium

Document information

Uploaded on
March 28, 2025
Number of pages
16
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$14.29

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Brainariam
3.4
(29)
Sold
158
Followers
7
Items
8420
Last sold
2 days ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions