ACNS EEG

_____ channels of simultaneous recording are considered the minimum number
required to show the areas producing most normal and abnormal EEG patterns. -
answer SIXTEEN

Experimental evidence suggests that ____________ or __________________
electrodes held on by collodion are the best, but other electrode materials and electrode
pastes have been used effectively, especially with contemporary amplifiers having high-
input impedances - answer silver—silver chloride or gold disk

Recording electrodes should not significantly attenuate signals between ____ and
______ Hz - answer0.5 and 70 Hz

Needle electrodes are ____ recommended for routine clinical use. Beyond
considerations of patient discomfort and risk of injuries to personnel, these electrodes
have higher impedances than appropriately applied cup electrodes, resulting in
potentially higher levels of noise. - answerNOT

Subdermal needle electrodes (SNE) or wire electrodes (SWE) may be used for
___________________ recording of EEG in stuporous or comatose patients in
situations where application of cup electrodes is ______ feasible because of personnel
or time constraints. - answerprolonged
not

he 10 to 20 System is the only one officially recommended by the _________.It is the
most commonly used system and should be used universally. - answerIFCN

In every case, an isolated __________ electrode should be placed and connected to
the jackbox as specified by the manufacturer. - answerground

The isolated ground does not allow __________________ currents to pass and is not a
safety hazard as were earth grounds used in early analog EEG devices. -
answerdangerous

Interelectrode impedances should be checked as a routine prerecording procedure.
With modern digital EEG recording equipment, impedances up to ___ k Ohms are
acceptable, but optimal recording still requires impedances that are balanced. -
answer10

Unbalanced impedances compromise the ability of an EEG amplifier to ________
potentials that are the same at a pair of electrodes while ________________ those that
are different (common mode rejection) - answerreject

, amplifying

Impedances should also not be below _____ Ohms because this usually indicates a
____________ or short circuit, possibly related to a salt bridge on the scalp. -
answer100
shunt

Electrode impedances should be rechecked during the recording when any pattern that
might be ________________ appears - answerartifactual

It is desirable that at least some montages in all laboratories be ______________ to
facilitate communication and comparison - answeruniform

The information associated with the record should include, as a minimum: - answerthe
name and age of the patient,
the date of the recording,
an identification number,
and the name or initials of the technologist.

Appropriate calibrations should be made at the beginning of every EEG recording. This
includes at least ___ seconds (or the duration needed to reach a stable recording) of a
square wave calibration. - answer10

In addition to the standard square-wave calibration, the biologic calibration may
occasionally help in detecting _________ in the montage selection process or in the
pen-writing mechanism for analog recordings. For this purpose, an
____________________ (frontooccipital) derivation should be used because it can
include fast and alpha range patterns as well as eye movement activity in the delta
range. - answererrors
anteroposterior

The calibration is an integral part of every EEG recording. It gives a ________________
factor for the interpreter and tests the EEG machine for sensitivity, high-frequency and
low-frequency response, noise level, and pen alignment and damping (for analog
systems). Calibration voltages must be appropriate for the sensitivities used during the
recording. After calibration, visual review of a 30-second run on the system reference
montage _____________ the notch filter is also recommended. - answerscaling

The sensitivity of the EEG equipment for routine recording should be set in the range of
_____ to _______ μV/mm of trace deflection. - answer5 to 10

Sensitivity is defined as the ratio of input ___________ to trace ___________. It is
expressed in microvolts per millimeter. - answervoltage
deflection

Document information

Uploaded on
March 28, 2025
Number of pages
5
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$13.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Dreamer252
4.0
(117)
Sold
497
Followers
297
Items
21509
Last sold
3 weeks ago




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions