100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

ASNT ULTRASONIC LEVEL I EXAM NEWEST 2025 ACTUAL EXAM QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+

Rating
-
Sold
-
Pages
23
Grade
A+
Uploaded on
24-03-2025
Written in
2024/2025

ASNT ULTRASONIC LEVEL I EXAM NEWEST 2025 ACTUAL EXAM QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+ Far boundary indication - CORRECT ANSWER ->The indication on the instrument display that represents the far boundary of the material being tested. Immersion testing - CORRECT ANSWER ->The position of the transducer is often varied to transmit sound into the test part at various angles to the front surface. Coaxial cable - CORRECT ANSWER ->The cable that connects the ultrasonic instrument to the transducer is specially designed so that one conductor is centered inside another. Calibration - CORRECT ANSWER ->The process of comparing an instrument or device with a standard. Compressional wave - CORRECT ANSWER ->Another name for a longitudinal wave. Rayleigh wave - CORRECT ANSWER ->Another name for surface waves. Couplant - CORRECT ANSWER ->A material used between the face of a transducer and the test surface to permit or improve the transmission of ultrasonic vibrations. Piezoelectric material - CORRECT ANSWER ->The material in a transducer that vibrates to produce ultrasonic waves. Ultrasonic testing - CORRECT ANSWER ->Testing of material where the transducer is in direct contact with the material being tested. Lithium sulfate - CORRECT ANSWER ->An advantage of using lithium sulfate in transducers is that it is one of the most efficient generators of ultrasonic energy. Transducer frequency - CORRECT ANSWER ->The transducer that contains the thinnest piezoelectric crystal is a 25 MHz transducer. Beam divergence - CORRECT ANSWER ->The amount of beam divergence from a crystal is primarily dependent on the frequency and crystal size. Refraction - CORRECT ANSWER ->When an ultrasonic beam passes through the interface between two dissimilar materials at an angle, a new angle of sound travel takes place in the second material. Indication A - CORRECT ANSWER ->Represents the initial pulse or front surface indication in Figure 2. Indication B - CORRECT ANSWER ->Represents the first discontinuity indication in Figure 2. Indication C - CORRECT ANSWER ->Represents the second back surface reflection in Figure 2. Indication D - CORRECT ANSWER ->Represents the second indication of the discontinuity in Figure 2. Indication E - CORRECT ANSWER ->Represents the second back surface reflection in Figure 2. Velocity of surface waves - CORRECT ANSWER ->Approximately the velocity of shear waves in the same material. Indication A - CORRECT ANSWER ->The first front surface indication. Indication B - CORRECT ANSWER ->First back surface reflection. Indication C - CORRECT ANSWER ->First discontinuity reflection. Indication D - CORRECT ANSWER ->Second discontinuity indication. Distance between indications A and B - CORRECT ANSWER ->The distance from the front surface of the aluminum block to the discontinuity. Best resolving power frequency - CORRECT ANSWER ->5 MHz. Greatest sound attenuation material - CORRECT ANSWER ->A coarse-grained casting. Entry surface indication in contact testing - CORRECT ANSWER ->The initial pulse. Ultrasonic instrument display pattern with low-level indications - CORRECT ANSWER ->Could be caused by a gas pocket. Test method with two transducers - CORRECT ANSWER ->Through-transmission testing. Number of complete waves in a given period - CORRECT ANSWER ->Frequency of a wave motion. Boundary between two materials - CORRECT ANSWER ->An interface. Longitudinal wave - CORRECT ANSWER ->When the motion of the particles of a medium is parallel to the direction of propagation. Shear wave - CORRECT ANSWER ->When the motion of the particles of a medium is transverse to the direction of propagation. 25 million cycles per second - CORRECT ANSWER ->Can also be stated as 25 MHz. Moving a transducer over a test surface - CORRECT ANSWER ->Scanning. Rate at which sound waves pass through substances - CORRECT ANSWER ->Velocity. Maximum signal height of a vertical indication - CORRECT ANSWER ->Distance amplitude height. Ultrasonic testing technique with non-parallel transducer elements - CORRECT ANSWER ->Angle beam testing. Angle of incidence - CORRECT ANSWER ->Angle 1 (01) in Figure 4. Angle of reflection - CORRECT ANSWER ->Angle 2 (02) in Figure 4. Angle of refraction - CORRECT ANSWER ->Angle 3 (03) in Figure 4. Commercial ultrasonic testing frequencies - CORRECT ANSWER ->Frequencies between 1 and 25 kHz, 1 and 1000 kHz, 0.2 and 25 MHz, or 15 and 100 MHz. Horizontal base line in A-scan - CORRECT ANSWER ->Represents the elapsed time or distance. Vertical indications in A-scan - CORRECT ANSWER ->Represents the amount of ultrasonic sound energy returning to the transducer.

Show more Read less
Institution
ASNT ULTRASONIC LEVEL I
Course
ASNT ULTRASONIC LEVEL I










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
ASNT ULTRASONIC LEVEL I
Course
ASNT ULTRASONIC LEVEL I

Document information

Uploaded on
March 24, 2025
Number of pages
23
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

1



ASNT ULTRASONIC LEVEL I EXAM NEWEST 2025
ACTUAL EXAM QUESTIONS AND CORRECT DETAILED
ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED
A+
Far boundary indication - (answers)The indication on the instrument display that
represents the far boundary of the material being tested.



Immersion testing - (answers)The position of the transducer is often varied to
transmit sound into the test part at various angles to the front surface.



Coaxial cable - (answers)The cable that connects the ultrasonic instrument to the
transducer is specially designed so that one conductor is centered inside another.



Calibration - (answers)The process of comparing an instrument or device with a
standard.



Compressional wave - (answers)Another name for a longitudinal wave.



Rayleigh wave - (answers)Another name for surface waves.



Couplant - (answers)A material used between the face of a transducer and the
test surface to permit or improve the transmission of ultrasonic vibrations.

, 2


Piezoelectric material - (answers)The material in a transducer that vibrates to
produce ultrasonic waves.



Ultrasonic testing - (answers)Testing of material where the transducer is in direct
contact with the material being tested.



Lithium sulfate - (answers)An advantage of using lithium sulfate in transducers is
that it is one of the most efficient generators of ultrasonic energy.



Transducer frequency - (answers)The transducer that contains the thinnest
piezoelectric crystal is a 25 MHz transducer.



Beam divergence - (answers)The amount of beam divergence from a crystal is
primarily dependent on the frequency and crystal size.



Refraction - (answers)When an ultrasonic beam passes through the interface
between two dissimilar materials at an angle, a new angle of sound travel takes
place in the second material.



Indication A - (answers)Represents the initial pulse or front surface indication in
Figure 2.



Indication B - (answers)Represents the first discontinuity indication in Figure 2.

, 3


Indication C - (answers)Represents the second back surface reflection in Figure 2.



Indication D - (answers)Represents the second indication of the discontinuity in
Figure 2.



Indication E - (answers)Represents the second back surface reflection in Figure 2.



Velocity of surface waves - (answers)Approximately _________ the velocity of
shear waves in the same material.



Indication A - (answers)The first front surface indication.



Indication B - (answers)First back surface reflection.



Indication C - (answers)First discontinuity reflection.



Indication D - (answers)Second discontinuity indication.



Distance between indications A and B - (answers)The distance from the front
surface of the aluminum block to the discontinuity.



Best resolving power frequency - (answers)5 MHz.

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Nurslink Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
216
Member since
2 year
Number of followers
72
Documents
1675
Last sold
2 weeks ago
Nurslink.

Pre-eminent study guidance.

3.4

23 reviews

5
8
4
6
3
3
2
0
1
6

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions