Content preview

ICC California UST Service Technician
Questions with Complete Solutions
(Latest 2025)
UDC was required at time of installation for all systems
installed after? - Correct Answers ✅January 1, 2000


July 1, 2005, service techs shall possess or work under
someone who has a current certification indicating he or she
has passed the? - Correct Answers ✅ICC UST Service
Technician Exam


ICC cert must be renewed every? - Correct Answers ✅24
months


Service techs must possess or be employed by a person who
has the appropriate contractor's license unless? - Correct
Answers ✅The individual has a tank testing license


Service tech is defined by any individual who? - Correct
Answers ✅Tests UST monitoring equipment, trouble shoots
UST systems, and/or installs UST monitoring equipment.


If the manufacturer training no longer exist, the local agency
may? - Correct Answers ✅Approve comparable alternate
training .


UST includes? - Correct Answers ✅Tank and connected
piping

,ICC California UST Service Technician
Questions with Complete Solutions
(Latest 2025)

What is considered a UST? - Correct Answers ✅A
petroleum storage tank.


What UST system meets the requirements for secondary
containment? - Correct Answers ✅Doubled wall tanks


According to title 23; the following piping components if
installed after July 1, 1987 must have secondary
containment. - Correct Answers ✅Pressured product piping


Considered "pipe" on tanks installed after July 1, 2003. -
Correct Answers ✅Pressured product piping and below
ground vapor recovery.


Under dispenser containment (UDC) was required for all
existing UST systems by - Correct Answers ✅December 31,
2003


System for exchanging gas vapors in a storage tank and
product in a fuel delivery truck - Correct Answers ✅Stage 1
vapor recovery

,ICC California UST Service Technician
Questions with Complete Solutions
(Latest 2025)
An approved method for non-visual monitoring for existing
UST systems. - Correct Answers ✅Statistical Inventory
Reconciliation (SIR)


ATG must be capable for detecting a release of? - Correct
Answers ✅0.2 gallons per hour


What is no longer an approved method for non-visual
monitoring on existing UST systems? - Correct Answers
✅Manual inventory reconciliation.


Automatic line leak detectors installed on underground piping
with secondary containment shall be capable of detecting a
leak of ? - Correct Answers ✅3 gallons per hour at 10 psi


How often should ATG be programmed to test the tank? -
Correct Answers ✅At least monthly


According to PEI RP 300, a combustible gas can be used to? -
Correct Answers ✅Detect vapor leaks in a vapor recovery
system.


According to PEI RP 300, a written scope of work for vapor
recovery installation should include? - Correct Answers
✅Construction plans

, ICC California UST Service Technician
Questions with Complete Solutions
(Latest 2025)

Positive shut off overfill protection device must stop the flow
of fuel when the tank is no more then? - Correct Answers
✅95% full


According to Executive Order (EO) VR 201-A , what could
cause a nozzle shut off mechanism or malfunction? - Correct
Answers ✅Depended filter seal damage


According to VR 201-A, breakaway reconnection must be? -
Correct Answers ✅Logged in GDF log


According to PEI RP 300 what is an INCORRECT method of
documenting piping location? - Correct Answers
✅Sketching a diagram on the inside cover of vapor recovery
equipment manual


According to PEI RP 300 as built drawing or pictures of the
underground pipping and other components shall
be_________. - Correct Answers ✅maintained as long as
UST is in service.


According to EO VR 101-E maintenance records are required
to include what? - Correct Answers ✅Name and
Designated UST Operator.

Document information

Uploaded on
March 22, 2025
Number of pages
47
Written in
2024/2025
Type
Exam (elaborations)
Contains
Unknown
$13.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Allivia
3.9
(149)
Sold
797
Followers
400
Items
16140
Last sold
1 day ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions