Type of sealant you should you use on a Phil-Tite Ball Float nipple: Correct
Answer - Pipe dope
Number of open valves on the clean air separator: Correct Answer - One
You must be CERTIFIED by Healy to re-connect a Healy breakaway, True or
False? Correct Answer - False
The type of pressure gauge is recommended to test Healy Vac Correct
Answer - SYSA gauge measuring 0-100 WC
On new construction, after July 1, 2004, Can you install an in-ground Spill
Bucket? Correct Answer - YES-When Piping is monitored and with VAC
According to Executive Order 201 - Healy P/V Valve should be torqued at
Correct Answer - 20-50 ft-lbs
For a fire to burn, these (3) three primary elements must exist: Correct
Answer - Fuel, Oxygen, Ignition Source
When working with Electrical - Lock Out Tag Out procedures are under these
guidelines. Correct Answer - CAL-OSHA
Organization that certifies vapor recovery systems. Correct Answer -
CARB or ARB
According to RP 500, a level II technician may NOT inspect this part.
Correct Answer - Replace VP 1000 Healy Pump
where hanging hardware repairs must be tracked. Correct Answer - GDF
maintenance log
approved sealant when assembling a Phil-Tite Drop Tube. Correct Answer -
JB-Kwik
, Material direct bury OPW container sleeve shall be made of. Correct
Answer - Stainless steel
What P/V vent cap shall be tightened to. Correct Answer - 20-50 ft lbs
From dispenser to manifold - 2" diameter vapor piping ( 2" ID) and From
manifold to tank - 3" diameter vapor piping (3" ID) Correct Answer -
Vapor piping
What is the maximum run for vapor piping? Correct Answer - No
maximum run
How you know a nozzle spout is bad. Correct Answer - 'BAD O-rinqs
According to PEI RP 300, on a balance Stage II vapor recovery system nozzle,
Vapors typically flow in what direction of the coaxial hose? Correct Answer
- The outside pathway
What is the maximum allowable number of P/V caps allowed on a UST fuel
system? Correct Answer - One
On a Healy Air Separator, there are four Ball Valves, the following shall be
observed? Correct Answer - One valve shall remain open on top
The Pressure settings for the UST Vent Cap is. Correct Answer - .0+-
0.5inches H2O Negative Pressure 1,0+-2.0 inches H2O Positive Pressure
Given that in a balance Stage II vapor recovery system, the nozzle is equipped
with a flexible nozzle bellows that seals around the automobile fill pipe. This is
how vapors will typically flow. Correct Answer - From the outside
pathway of the coaxial hose
The Healy 1301 flow limiter shall be used when the flow rate exceeds this.
Correct Answer - 10.0 GPM
Given that: The VP1000 vacuum pump motor will operate automatically when
the temperature drops. The VP1000 will automatically operate when the
temperature drops below this temperature. Correct Answer - 40 f (35f if
40f is not an option)
Solutions
Type of sealant you should you use on a Phil-Tite Ball Float nipple: Correct
Answer - Pipe dope
Number of open valves on the clean air separator: Correct Answer - One
You must be CERTIFIED by Healy to re-connect a Healy breakaway, True or
False? Correct Answer - False
The type of pressure gauge is recommended to test Healy Vac Correct
Answer - SYSA gauge measuring 0-100 WC
On new construction, after July 1, 2004, Can you install an in-ground Spill
Bucket? Correct Answer - YES-When Piping is monitored and with VAC
According to Executive Order 201 - Healy P/V Valve should be torqued at
Correct Answer - 20-50 ft-lbs
For a fire to burn, these (3) three primary elements must exist: Correct
Answer - Fuel, Oxygen, Ignition Source
When working with Electrical - Lock Out Tag Out procedures are under these
guidelines. Correct Answer - CAL-OSHA
Organization that certifies vapor recovery systems. Correct Answer -
CARB or ARB
According to RP 500, a level II technician may NOT inspect this part.
Correct Answer - Replace VP 1000 Healy Pump
where hanging hardware repairs must be tracked. Correct Answer - GDF
maintenance log
approved sealant when assembling a Phil-Tite Drop Tube. Correct Answer -
JB-Kwik
, Material direct bury OPW container sleeve shall be made of. Correct
Answer - Stainless steel
What P/V vent cap shall be tightened to. Correct Answer - 20-50 ft lbs
From dispenser to manifold - 2" diameter vapor piping ( 2" ID) and From
manifold to tank - 3" diameter vapor piping (3" ID) Correct Answer -
Vapor piping
What is the maximum run for vapor piping? Correct Answer - No
maximum run
How you know a nozzle spout is bad. Correct Answer - 'BAD O-rinqs
According to PEI RP 300, on a balance Stage II vapor recovery system nozzle,
Vapors typically flow in what direction of the coaxial hose? Correct Answer
- The outside pathway
What is the maximum allowable number of P/V caps allowed on a UST fuel
system? Correct Answer - One
On a Healy Air Separator, there are four Ball Valves, the following shall be
observed? Correct Answer - One valve shall remain open on top
The Pressure settings for the UST Vent Cap is. Correct Answer - .0+-
0.5inches H2O Negative Pressure 1,0+-2.0 inches H2O Positive Pressure
Given that in a balance Stage II vapor recovery system, the nozzle is equipped
with a flexible nozzle bellows that seals around the automobile fill pipe. This is
how vapors will typically flow. Correct Answer - From the outside
pathway of the coaxial hose
The Healy 1301 flow limiter shall be used when the flow rate exceeds this.
Correct Answer - 10.0 GPM
Given that: The VP1000 vacuum pump motor will operate automatically when
the temperature drops. The VP1000 will automatically operate when the
temperature drops below this temperature. Correct Answer - 40 f (35f if
40f is not an option)