ICC Vapor Recovery - VT Test Questions with Correct Answers Graded A+ Type of sealant you should you use on a Phil-Tite Ball Float nipple: - Answers Pipe dope Number of open valves on the clean air separator: - Answers One You must be CERTIFIED by Healy to re-connect a Healy breakaway, True or False? - Answers False The type of pressure gauge is recommended to test Healy Vac - Answers SYSA gauge measuring 0-100 WC On new construction, after July 1, 2004, Can you install an in-ground Spill Bucket? - Answers YES-When Piping is monitored and with VAC According to Executive Order 201 - Healy P/V Valve should be torqued at - Answers 20-50 ft-lbs For a fire to burn, these (3) three primary elements must exist: - Answers Fuel, Oxygen, Ignition Source When working with Electrical - Lock Out Tag Out procedures are under these guidelines. - Answers CAL-OSHA Organization that certifies vapor recovery systems. - Answers CARB or ARB According to RP 500, a level II technician may NOT inspect this part. - Answers Replace VP 1000 Healy Pump where hanging hardware repairs must be tracked. - Answers GDF maintenance log approved sealant when assembling a Phil-Tite Drop Tube. - Answers JB-Kwik Material direct bury OPW container sleeve shall be made of. - Answers Stainless steel What P/V vent cap shall be tightened to. - Answers 20-50 ft lbs From dispenser to manifold - 2" diameter vapor piping ( 2" ID) and From manifold to tank - 3" diameter vapor piping (3" ID) - Answers Vapor piping What is the maximum run for vapor piping? - Answers No maximum run How you know a nozzle spout is bad. - Answers 'BAD O-rinqs According to PEI RP 300, on a balance Stage II vapor recovery system nozzle, Vapors typically flow in what direction of the coaxial hose? - Answers The outside pathway What is the maximum allowable number of P/V caps allowed on a UST fuel system? - Answers One On a Healy Air Separator, there are four Ball Valves, the following shall be observed? - Answers One valve shall remain open on top The Pressure settings for the UST Vent Cap is. - Answers .0+- 0.5inches H2O Negative Pressure 1,0+-2.0 inches H2O Positive Pressure Given that in a balance Stage II vapor recovery system, the nozzle is equipped with a flexible nozzle bellows that seals around the automobile fill pipe. This is how vapors will typically flow. - Answers From the outside pathway of the coaxial hose The Healy 1301 flow limiter shall be used when the flow rate exceeds this. - Answers 10.0 GPM Given that: The VP1000 vacuum pump motor will operate automatically when the temperature drops. The VP1000 will automatically operate when the temperature drops below this temperature. - Answers 40 f (35f if 40f is not an option) How do you verify a nozzle spout is bad and needs to be replaced? - Answers Test the nozzle Given that a "Classified Area" is a located where a fire and explosion hazard exists due to the presence of fuel vapors. Because vapors are heavier than air In a Class I, Division 2 area, where may vapors be present - Answers Extending 20 feet from dispensers to a height of 1.5 feet above ground absorbent pads, and absorbent boom, fuel absorbet material - Answers When responding to Fuel Spills, it is advisable to have the following equipment.

Content preview

ICC Vapor Recovery - VT Test Questions with Correct Answers Graded A+

Type of sealant you should you use on a Phil-Tite Ball Float nipple: - Answers Pipe dope

Number of open valves on the clean air separator: - Answers One

You must be CERTIFIED by Healy to re-connect a Healy breakaway, True or False? - Answers False

The type of pressure gauge is recommended to test Healy Vac - Answers SYSA gauge measuring 0-100
WC

On new construction, after July 1, 2004, Can you install an in-ground Spill Bucket? - Answers YES-When
Piping is monitored and with VAC

According to Executive Order 201 - Healy P/V Valve should be torqued at - Answers 20-50 ft-lbs

For a fire to burn, these (3) three primary elements must exist: - Answers Fuel, Oxygen, Ignition Source

When working with Electrical - Lock Out Tag Out procedures are under these guidelines. - Answers CAL-
OSHA

Organization that certifies vapor recovery systems. - Answers CARB or ARB

According to RP 500, a level II technician may NOT inspect this part. - Answers Replace VP 1000 Healy
Pump

where hanging hardware repairs must be tracked. - Answers GDF maintenance log

approved sealant when assembling a Phil-Tite Drop Tube. - Answers JB-Kwik

Material direct bury OPW container sleeve shall be made of. - Answers Stainless steel

What P/V vent cap shall be tightened to. - Answers 20-50 ft lbs

From dispenser to manifold - 2" diameter vapor piping ( 2" ID) and From manifold to tank - 3" diameter
vapor piping (3" ID) - Answers Vapor piping

What is the maximum run for vapor piping? - Answers No maximum run

How you know a nozzle spout is bad. - Answers 'BAD O-rinqs

According to PEI RP 300, on a balance Stage II vapor recovery system nozzle, Vapors typically flow in
what direction of the coaxial hose? - Answers The outside pathway

What is the maximum allowable number of P/V caps allowed on a UST fuel system? - Answers One

On a Healy Air Separator, there are four Ball Valves, the following shall be observed? - Answers One
valve shall remain open on top

, The Pressure settings for the UST Vent Cap is. - Answers .0+- 0.5inches H2O Negative Pressure 1,0+-2.0
inches H2O Positive Pressure

Given that in a balance Stage II vapor recovery system, the nozzle is equipped with a flexible nozzle
bellows that seals around the automobile fill pipe. This is how vapors will typically flow. - Answers From
the outside pathway of the coaxial hose

The Healy 1301 flow limiter shall be used when the flow rate exceeds this. - Answers 10.0 GPM

Given that: The VP1000 vacuum pump motor will operate automatically when the temperature drops.
The VP1000 will automatically operate when the temperature drops below this temperature. - Answers
40 f (35f if 40f is not an option)

How do you verify a nozzle spout is bad and needs to be replaced? - Answers Test the nozzle

Given that a "Classified Area" is a located where a fire and explosion hazard exists due to the presence
of fuel vapors. Because vapors are heavier than air In a Class I, Division 2 area, where may vapors be
present - Answers Extending 20 feet from dispensers to a height of 1.5 feet above ground

absorbent pads, and absorbent boom, fuel absorbet material - Answers When responding to Fuel Spills,
it is advisable to have the following equipment.

In accordance with PEI RP-500, a Level II Qualified Person may not perform what duty? - Answers
Replace a Healy VP1000 Pump

Volatile Organic Compounds - Answers VOC's

What does a Combustible-Gas Detector check for in Vapor Recovery Systems? - Answers Leaks/Vapors in
Vapor Recovery Systems {or LELor LFL 10% max)

8.0 +- 2.0, The P/V Cap has a black sticker with gold letters stating these positive/negative specs: -
Answers 3.0 +- 0.5

This is what connecting above ground vent lines together is called. - Answers Manifolding

Continuous monitoring which includes pressure (hydrostatic), vacuum in brine, was required after July 1,
2004 for which station components? - Answers Sumps and UDCs

The Healy VPl000 runs at a higher RPM under what circumstances? - Answers When both sides are
activated and nozzles are removed from the dispenser

Where is the Vapor valve located at? - Answers Under the dispenser (nozzle is second choice if dispenser
is not available)

When installing a ball float vent valve, what type of sealant shall you use? - Answers A gasoline resistant
compound

Document information

Uploaded on
March 12, 2025
Number of pages
7
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$10.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TutorJosh
3.5
(77)
Sold
508
Followers
16
Items
33052
Last sold
1 day ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions