Example of nonspecular reflector - correct answers-red blood cells

What happens to spatial pulse length when frequency increases? - correct answers-decreases

Axial resolution is dependent on? - correct answers-wavelength

Lateral resolution is dependent on? - correct answers-beam diameter

Where does the beam of an unfocused transducer diverge? - correct answers-Fraunhofer zone

Reverberation artifacts are a result of - correct answers-two or more strong reflecting surfaces

True/False: Grating lobes are essential for the proper operation of a linear phased array. - correct
answers-False

True/False: Electronically steered scanners always produce higher resolution images than do
mechanically steered scanners. - correct answers-False

True/False: An annular array scanner uses mechanical beam steering. - correct answers-True

True/False: A linear sequenced array cannot be dynamically focused. - correct answers-False

registration or B-mode alignment - correct answers-Which AIUM test object function utilizes all the
groups of wires in the AIUM 100 mm test object?

axial resolution - correct answers-Which AIUM test object function utilizes the A group of wires in the
AIUM 100 mm test object?

lateral resolution - correct answers-Which AIUM test object function utilizes the B group of wires in the
AIUM 100 mm test object?

dead zone - correct answers-Which AIUM test object function utilizes the D group of wires in the AIUM
100 mm test object?

depth calibration - correct answers-Which AIUM test object function utilizes the C or E groups of wires in
the AIUM 100 mm test object?

What happens to axial resolution when spatial pulse length is decreased? - correct answers-improves

How much will a 3.5 MHz pulse be attenuated after passing through 2 cm of soft tissue? - correct
answers-3.5 dB

Propagation speed errors result in - correct answers-improper axial position

Enhancement is caused by - correct answers-weakly attenuating structures

The Doppler shift frequency is - correct answers-directly proportional to the velocity of the reflector

,The number of frames per second necessary for a real-time image to be flicker free is - correct answers-
more than 15

True/False: The SPTA intensity will always be larger than the SATA intensity. - correct answers-True

The intensity of the ultrasound beam is usually greater at the focal zone because of - correct answers-
the smaller beam diameter

If the amplitude is doubled, the intensity is - correct answers-quadrupled

The attenuation for soft tissue is - correct answers-increased with tissue thickness

The acoustic impedance of the matching layer - correct answers-can be chosen to improve transmission
into the body

True/False: In a pulse-echo system, the quality factor should be made as large as possible. - correct
answers-False

True/False: The beam diameter is constant in the near zone. - correct answers-False

The operating frequency is dependent on - correct answers-thickness of the crystal

The period of an ultrasound wave is - correct answers-the time of one wavelength

The dynamic range of a system is - correct answers-the ratio of smallest to largest power level that the
system can handle

True/False: The intensity of an ultrasonic beam can be measured with radiation force balance. - correct
answers-True

Increasing the pulse repetition period - correct answers-increases the maximum depth that can be
imaged

Ultrasound bioeffects - correct answers-are not confirmed below 100 mW/cm² SPTA

True/False: No refraction can occur at an interface if the media impedances are equal. - correct answers-
False

True/False: Smaller transducers always produce smaller beam diameters. - correct answers-False

True/False: The ultrasound beam profile can be measured with a hydrophone. - correct answers-True

True/False: The pulsed-Doppler system yields better depth resolution than the continuous wave (CW)
system. - correct answers-True

True/False: The gray-scale display was made possible when digital scan converters replaced analog scan
converters. - correct answers-False

True/False: Videotape recorders operating at 30 frames per second cannot be used with mechanical
real-time units because the fram rate is too slow. - correct answers-False

True/False: Linear phased array scanners need no form of mechanical focusing because focusing is
performed electronically. - correct answers-False

,True/False: The fram rate of real-time scanners depends on the number of lines used to form the image.
- correct answers-True

True/False: It is not possible to steer an annular phased array electronically. - correct answers-True

True/False: The near zone length should be kept as short as possible. - correct answers-False

What percentage of intensity of an ultrasound pulse incident on an interface of 0.25 and 0.75 rayls is
reflected? - correct answers-25%

Axial resolution can be improved by using - correct answers-higher frequency transducers

When particle motion of a medium is parallel to the direction of a wave propagation, the wave being
transmitted is called a - correct answers-longitudinal wave

The wavelength in a material having a wave velocity of 1500 m/s emplying a transducer frequency of 5
MHz is - correct answers-0.3 mm

The factor that determines the amount of reflection at the interface of two dissimilar materials is -
correct answers-difference in acoustic impedances

The equation that describes the relationship among propagation, wavelength, and frequency is - correct
answers-λ = c/ƒ

What three things can occur when an ultrasonic beam reaches the interface of two dissimilar materials?
- correct answers-reflection, refraction, mode conversion

The acoustic impedance of a material is - correct answers-equal to the product of density and velocity

The average velocity of ultrasonic waves in soft tissue is - correct answers-1540 m/s

True/False: Receiver-angle values in CW Doppler analysis do not influence the final Doppler shift. -
correct answers-False

Refraction occurs because of difference in ______ across an interface between two materials - correct
answers-wave velocity

Reflection factor at an interface between two materials depends primarily on the change in ______
across the interface. - correct answers-acoustic impedance

The velocity of sound waves is primarily dependent on - correct answers-medium and mode of vibration

Increasing the frequency of an ultrasonic longitudinal wave will result in ______ in the velocity of that
wave. - correct answers-no change

The change in direction of an ultrasonic beam, when it passes from one medium to another, in which
elasticity and density differ from those of the first medium is called - correct answers-refraction

A long near zone can be obtained by - correct answers-using a higher frequency transducer

If a 2 MHz frequency is used in human soft tissue, the wavelength is approximately - correct answers-
0.75 mm

, The ratio of particle pressure to particle velocity at a given point within the ultrasonic field is - correct
answers-impedance

What is the following formula used to determine?

(2 × velocity of reflector × original frequency) / velocity of sound - correct answers-Doppler shift
frequency

The principle that states that all points on a wavefront can be considered as point sources for the
production of sperical secondary wavelets was postulated by - correct answers-Huygens

A 10 dB difference in signal intensity is equivalent to a _______ difference. - correct answers-tenfold

The level below which signals are not transmitted through an ultrasound receiver system is the - correct
answers-threshold, negative, reject level

Gray-scale systems typically use _____ as a means of signal dynamic range reduction. - correct answers-
compression

The strength of the echo is related to the height of the deflection on the oscilloscope for the ____
display. - correct answers-A-mode

What are methods of restricting the dynamic range of the signal? - correct answers-suppression,
rejection, compression

Most of the scan converters currently in use are of the _____ type? - correct answers-digital

The fraction of time that pulsed ultrasound is actually on is the - correct answers-duty factor

The ability of an imaging system to detect weak reflections is called - correct answers-sensitivity

What image shape is produced by a linear sequenced array transducer? - correct answers-rectangular

The major factor in determining the acoustic power output of the transducer is the - correct answers-
magnitude of the voltage spike

Two primary mechanisms that produce tissue biological effects are - correct answers-thermal and
cavitational

The _____ relates bandwidth to operating frequency. - correct answers-quality factor, Q Factor

The extraneous beams of ultrasound generated from the edges of individual transducer elements and
not in the direction of the main ultrasonic beam are called - correct answers-side lobes

The product of the period and the number of cycles in the pulse is the - correct answers-pulse duration

The substance typically used as a matrix on the imaging surface of an analog scan converter tube is -
correct answers-silicon oxide

Specular reflection occurs when - correct answers-the reflector surface is small and smooth as
compared with wavelength

Document information

Uploaded on
March 10, 2025
Number of pages
35
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$10.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
EliteStudyHub
2.0
(11)
Sold
94
Followers
6
Items
9677
Last sold
1 week ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions