SSOPPs - Answers Forceful Backup
Formality
Procedural Compliance
Integrity
Questioning Attitude
Level of Knowledge
Ownership
Self-sufficiency
Four supporting processes of SSOPPs - Answers ORM
Supervisory control
PBED/P5
Critiques and Lessons Learned Reporting
Engineering Department Primary Task - Answers Maintain and operate engineering plant in high state of
readiness to support ships mission
Six management precepts of engineering - Answers Enforce quality training and qualifications
PQS
Clear communications
Increased level of knowledge
Adherence to approved operational procedures
Adherence to approved maintenance procedures
Fuel oil and lube oil leak standards in this pub - Answers EDORM
Oil Leak classifications - Answers Running leakage: >10 drops in 5 mins
Leakage: 6-10 drops in 5 mins
Seepage: 1-5 drops in 5 mins
Weepage: visible sheen
,Gas turbine F/O pub - Answers GGTB No. 17
Diesel F/O pub - Answers NSTM 233
Piping, Valves, and Flange Shield pub - Answers NSTM 505
DC & Firefighting and equipment pub - Answers NSTM 555
Balanced Joiner Door (Ellison Door) pub - Answers NSTM 600
L/O Pump pub - Answers NSTM 503
Steam pub - Answers NSTM 231
F/O Leak Tolerance - Answers No leaks allowed
Steam L/O leakage tolerance - Answers No leaks allowed
Portable CO2 - Answers Pin with tamper seal
Hose and nozzle secured
Stenciled/labeled
Tag with PMS date
Hydrostatic test date (within 12 years)
Balanced joiner door specs - Answers Closing speed range 6-8 seconds optimal
5-10 seconds acceptable
Frame and gasket clearance 1/16 inch
Calibration pubs - Answers JFMM
NAVSEAINST 4734.1
Flexible hoses pub - Answers TED-010
Flexible hose life - Answers Critical - 12 years
20 years with life extension program
Non-critical - when fails PMS or life of ship
Critical flexible hose criteria - Answers Mission critical
Failure impacts systems related to safety
, Hazardous fluid or pressure
Beyond ships repair capability
Operating log - Answers Records parameters on hourly basis
Indicates min/max parameters
Situational logs - Answers Logs not requiring hourly readings
Ex: daily fuel and water, boat report, etc
Out of parameters log entry - Answers Circle in red
Cause
Corrective action
Op log retention time - Answers 6 months recommended by ASA
Ex: lube oil sample log 2 years, heat stress surveys 1 year
Engineering Log retention time - Answers 3 years
Engineers bell book retention - Answers 3 years
Engineers bell book times of use - Answers When shaft is moving, including PMS
When auto logger is inop or offline
At all times plant not secured
CO Approval Items - light off - Answers Commence MLOCs
Major changes to plant config
Desig of safety observer other than EOOW, PPWO, RCO to observe light off
CO approval items - procedures, testing, repairs - Answers Use of battle override
Re-commence equipment after suspected tampering
Op testing main engines
Bypassing interlocks
Deviation from EOSS
Approval of LOPs where no EOSS available