International Mechanical Code Study
Guide – IMC Exam Preparation & HVAC
Code Review
Guidehttps://www.stuvia.com/dashboard!@_)#*)(@$)($@*($@)($@*_
International Mechanical Code
International
Study GuideMechanical
– IMC Exam
Code
International
Preparation
Study GuideMechanical
&–
HVAC
IMCCode
Exam
Code
Review.pdf
Preparation
Study Guide&–
HVAC
IMCCode
ExamReview.pdf
Preparation & HVAC Code Review.pdf
,International Mechanical Code Study Guide.pdf International Mechanical Code Study Guide.pdf International Mechanical Code Study Guide.pdf
luminaire and a receptacle outlet zone
3 4
[imc-306.3.1] [imc-202]
Don't know?
Terms in this set (111)
What is the clearance reduction above the appliance 18 inches
for a horizontal 24 gage sheet metal connector over
1-inch glass fiber reinforced with wire on rear face [IFGC-T-308.4.2]
with vented airspace?
Working clearance of passageways around all sides 18
of boilers shall have an unobstructed width of not
less than ____ inches. [IMC-1004.3]
International Mechanical Code Study Guide.pdf International Mechanical Code Study Guide.pdf International Mechanical Code Study Guide.pdf
,International Mechanical Code Study Guide.pdf International Mechanical Code Study Guide.pdf International Mechanical Code Study Guide.pdf
Safety or relief valves shall be installed directly into by gravity
the safety or relief valve opening on the boiler. The
relief valve shall discharge _______ . [IMC-1006.5]
Low-water cutoff controls and flow sensing controls combustion operation
shall automatically stop the _____ of the appliance
when the water level drops below the lowest safe [IMC-1007.2]
water level.
International Mechanical Code Study Guide.pdf International Mechanical Code Study Guide.pdf International Mechanical Code Study Guide.pdf
, International Mechanical Code Study Guide.pdf International Mechanical Code Study Guide.pdf International Mechanical Code Study Guide.pdf
You do not need a permit when you _____ a replace any minor part 106.1, IMC 2018 page 3
mechanical system.
[IMC-106.1]
How much mechanical ventilation exhaust air is 3500 cfm
needed if you have a refrigerant detector alarm in a
Central Plant where you have one chiller with 775# of [IMC-1105.6.3.2]
R-11 refrigerant and another chiller with 1225# of R-
123 refrigerant?
Refrigerant piping that crosses an open space that 7 feet 3 inches
affords passageway in any building shall be not less
than ____ above the floor unless the piping is located [IMC-1107.2]
against the ceiling of such space.
The use of air as a Test Gas is allowed to test _______ , R-717
ammonia, systems provided that they are
subsequently evacuated before charging with [IMC-1108.2]
refrigerant.
International Mechanical Code Study Guide.pdf International Mechanical Code Study Guide.pdf International Mechanical Code Study Guide.pdf