QUESTIONS |GUARANTEED
ACCURATE ANSWERS |VERIFIED
which of the following technical factors adjustments should be made
when negative contrast media agents are used?
A. decrease kilovoltage peak (kVp)
B. increase kilovoltage peak (kVp)
C. increased milliampere seconds (mAs)
D. decreased milliampere seconds (mAs) - ACCURATE ANSWERS✔✔
A. decrease kilovoltage peak (kVp)
a patient is seen in the emergency department with a possible fracture of
the 4th finger which of the following would be proper positioning for
this patient?
A. lateral projection with the arm resting on the ulnar surface
B. anteriorpostier (AP) projection with the finger curled as much as
possible
C. oblique projection with the arm resting on the radial surface
D. posteroanterior (PA) projection with the hand curled around a sponge
- ACCURATE ANSWERS✔✔ A. lateral projection with the arm resting
on the ulnar surface
, which of the following characteristics describes x-ray beams used in
diagnostic radiography
A. polyenergetic
B. heterogeneous
C. homogeneous
D. monoenergetic - ACCURATE ANSWERS✔✔ A. polyenergetic & B.
heterogeneous
a histogram in digital radiography refers to:
A. the number of brightness levels that can be assigned to a pixel
B. the size of the digital matrix
C. the frequency of recored exposure values
D. the range of exposure values that can be detected by the receptor -
ACCURATE ANSWERS✔✔ C. the frequency of recored exposure
values
during a series of a mobile chest x-rays in the emergency room
department , the technologist fails to adjust kilovoltage peak (kVp) for a
hypersthenic patient after their previous asthenic patient . this is likely to
result in which of the following?
A. saturation
B. excessive image receptor exposure
C. ghosting
D. quantum mottle - ACCURATE ANSWERS✔✔ D. quantum mottle