LIQUID PENETRANT STUDY GUIDE QUESTIONS WITH ANSWERS 2025/2026 GRADED A+ How long must a port be kept wet with penetrate before the removal process is started - It varies depending on penetrant used, material testing, sensitivity desired, and the type of discontinuities to be detected Which of the following factors will affect resolution of penetrant indications - 1. The sensitivity of the penetrant materials used 2. The surface condition of the part 3. The temperature of the part and/or penetrate Which of the following is an acceptable method for applying a web developers - Spraying or dipping When using a fluorescent penetrant, the actual inspection must be performed - In a darkened area under a black light A generally excepted method for removing excess non-water washable penetrant is - Wiping in cautiously cleaning the test specimen with a cleaner dampened cloth Why is it not advisable to look directly into a black light - It will possibly cloud the vision of the person looking into the light for a short period of time

Content preview

LIQUID PENETRANT STUDY GUIDE QUESTIONS WITH
ANSWERS 2025/2026 GRADED A+
How long must a port be kept wet with penetrate before the removal process is started -
It varies depending on penetrant used, material testing, sensitivity desired, and the type
of discontinuities to be detected

Which of the following factors will affect resolution of penetrant indications - 1. The
sensitivity of the penetrant materials used
2. The surface condition of the part
3. The temperature of the part and/or penetrate

Which of the following is an acceptable method for applying a web developers -
Spraying or dipping

When using a fluorescent penetrant, the actual inspection must be performed - In a
darkened area under a black light

A generally excepted method for removing excess non-water washable penetrant is -
Wiping in cautiously cleaning the test specimen with a cleaner dampened cloth

Why is it not advisable to look directly into a black light - It will possibly cloud the vision
of the person looking into the light for a short period of time

The failure to completely remove acid materials for my part before fluorescent penetrant
is applied will result in - A decrease in the florescence of the penetrant

Penetrance may be classified or subdivided by the method used to remove excess
penetrate. Which of the following is a proper classification in accordance with the
statement - Water-washable

Which of the following surface contaminants cannot be removed by cleaning ports in a
vapor degreaser - Rust

Which of the following is not a basic inspection principle that applies to all penetrant
methods - Indications glow when illuminated with a black light

Which of the following parts could not be tested by the liquid penetrate method - Apart
made from a porous material

Usually, the most desirable method of removing excess water washable penetrant after
the dwell time is by - A low pressure coarse water spray

The purpose of an emulsifier is to - Combine with the penetrant to make the result
mixture removable by a water rinse

, Which of the following are commonly excepted methods for applying penetrants - 1.
Dipping the part in penetrant (dipping)
2. Pouring the penetrant over the test specimen (flowing)
3. Spraying the penetrate on the test specimen (spraying)

The penetrant applied to the surface of a test specimen - is drawn into discontinuities by
capillary action

When conducting a water washable liquid penetrant test, the web developer is applied -
After removal of the penetrant

Which of the following penetrant methods does not normally require a source of
electricity to properly conduct a test - Visible dye pentrant method

Which of the following penetrant systems is generally considered least sensitive - water
-washable, visible dye.

Black light with a proper functioning filter in place used for fluorescent penetrate
inspection can cause permanent damage to - None of the below
Human tissues, human eyes, human blood cells

Developer assist in the detection of liquid penetrant indications by - Providing a
contrasting background

Which of the following statements is true - If the dryer is too high, the heat may degrade
the effectiveness of the penetrate

Material which when applied over the film of the penetrant on the surface of a part
mixes with the penetrant, and which enables it to be washed off the surface is - An
emulsifier

Black light equipment is required when doing penetrant testing by the - Fluorescent
penetrant method

Liquid penetration testing is capable of detecting - discontinuities open to the surface

The term used to define the tendency of certain liquids to penetrate into small openings
such as cracks or fissures is - Capillary action

When using a web developer - A thin layer of developer is better than a thick layer for
showing very fine cracks

Color contrast penetrants are commercially available in which of the following variations
- 1. Normal solvent clean type
2. Water wash type
3. Post emulsification time

Document information

Uploaded on
February 22, 2025
Number of pages
6
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$10.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
BOARDWALK
3.5
(41)
Sold
287
Followers
11
Items
36004
Last sold
6 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions