Question: What refers to the maximum voltage that can be reached by a signal? - CORRECT
ANSWER✔✔Amplitude




Question: Electricity may flow only when? - CORRECT ANSWER✔✔There has to be a for it to
return making a complete circuit



Question: What is the return path for electrical power to flow back to the service panel? -
CORRECT ANSWER✔✔Neutral




Question: The live wire is always ungrounded? - CORRECT ANSWER✔✔True. They are very hot
caring electrical power




Question: A ground electrode conductor originates at the neutral or equipment ground bus of
the service panel? - CORRECT ANSWER✔✔True




Question: A ground electrode should not be made in contact with the earth? - CORRECT
ANSWER✔✔False. sound be on contact with the earth

, Page 2 of 51




Question: Compare Watts with Voltage - CORRECT ANSWER✔✔Watts are the measure of
power. Voltage is the measure of potential energy.




Question: You should size conductors no less ______ of the continuous loads plus _________ of
the non-continuous loads,. - CORRECT ANSWER✔✔125% / 100%




Question: Conductor sizes are often expressed in? - CORRECT ANSWER✔✔American Wire Gage
(AWG)



Question: What refers to the allowable current-carrying capacity of a conductor? - CORRECT
ANSWER✔✔Ampacity




Question: The insulation type determines the areas the writers can and cannot used? -
CORRECT ANSWER✔✔True




Question: RHH wires use rubber insulation that is high heat resistant and is good in? - CORRECT
ANSWER✔✔Is only good in dry locations.




Question: RHW-2 wires use the rubber insulation but are suitable for wet locations? - CORRECT
ANSWER✔✔True

, Page 3 of 51


Question: What cables can be used inside wall, ceiling or under the floor. - CORRECT
ANSWER✔✔Non-metallic (NM)




Question: What cables are most appropriate for damp areas? - CORRECT
ANSWER✔✔Underground feeder (UF) or Non-metallic Wet underground (NMWU)




Question: THWN means? - CORRECT ANSWER✔✔Flame retardant, Heat resistant, Moisture
resistant, Gasoline resistant, and oil resistant.



Question: An insulated grounded conductor which is ____ AWG or below should be identified
by a continuous white or gray outer finish. - CORRECT ANSWER✔✔6 AWG




Question: What is the amount of voltage measured between any two line conductors of a
balanced three-phase system. - CORRECT ANSWER✔✔Line voltage




Question: What describes the voltage measured across any one component of a balanced
three-phase system. - CORRECT ANSWER✔✔Phase Voltage




Question: A _______ is unintentional mess up. - CORRECT ANSWER✔✔Ground Fault




Question: An effective Ground-Fault current path is? - CORRECT ANSWER✔✔An effective
Ground-Fault current paths a path intentionally constructed to facilitate the operation of the
overcurrent protective devices currently in place.

, Page 4 of 51




Question: GFCI is never sensitive to small "leaks" of current - CORRECT ANSWER✔✔False. GFCI
= ground-fault circuit interrupter




Question: Grounding and bonding means exactly the same thing? - CORRECT ANSWER✔✔False.
Bonding is a means of allowing electrical continuity between metallic objects.



Question: A typical work space (for a working voltage under 600V) should have a minimum
headroom of ______ m. - CORRECT ANSWER✔✔2.0 m




Question: typically there are ____ hot wires running from the utility company into the service
panel. - CORRECT ANSWER✔✔2




Question: A service disconnect need to have a rating which is? - CORRECT ANSWER✔✔No less
than that the calculated load or for the type of installation




Question: Fast- blow fuses tend to open real quick when the rated current is reached. -
CORRECT ANSWER✔✔True




Question: System grounding is required when you have a supply transformer of a SOV or lower
system? - CORRECT ANSWER✔✔System grounding is required when you have a supply
transformer of a 50V or lower system which itself is supplied from a source over 150V to the
ground

Document information

Uploaded on
February 22, 2025
Number of pages
51
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$13.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ressyshii
3.8
(10)
Sold
69
Followers
7
Items
2357
Last sold
3 weeks ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions