Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 4 out of 31 pages
Exam (elaborations)

ASNT ULTRASONIC LEVEL I EXAM NEWEST 2025 ACTUAL EXAM COMPLETE 170 QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+

Document preview thumbnail
Preview 4 out of 31 pages

ASNT ULTRASONIC LEVEL I EXAM NEWEST 2025 ACTUAL EXAM COMPLETE 170 QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+

Content preview

ASNT ULTRASONIC LEVEL I EXAM NEWEST 2025 ACTUAL EXAM COMPLETE 170 QUESTIONS AND
CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+


1. The indication on the instrument display that repre- the back surface reflec-
sents the far boundary of the material being tested is tion.
called:

2. In immersion testing, the position of the transducer is angulation.
often varied by a manipulator to transmit sound into
the test part at various angles to the front surface.
Such a procedure is referred to as:

3. The technical name for the cable that connects the conduit.
ultrasonic instrument to the transducer is:

4. The process of standardizing an instrument or device calibration.
by using a reference standard is called:
"家的爱"
5. Another name for a compressional wave is: longitudinal wave(Jiā de
ài)

6. Another name for Rayleigh waves is: surface waves

7. A material used between the face of a transducer and couplant
the test surface to permit or improve the transmission
of ultrasonic vibrations from the transducer to the
material being tested is called:

8. The piezoelectric material in a transducer that vibrates crystal
to produce ultrasonic waves is called a:

9. Ultrasonic testing of material where the probe is in straight beam testing
direct contact with the material being tested may be:

10. An advantage of using lithium sulfate in transducers is one of the most eflcient
is that it: receivers of ultrasonic en-
ergy.




, ASNT ULTRASONIC LEVEL I EXAM NEWEST 2025 ACTUAL EXAM COMPLETE 170 QUESTIONS AND
CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+


11. The transducer shown in figure 1 is used for: straight beam testing




12. The transducer that contains the thinnest piezoelec- 25mhz
tric crystal is:
a: 1 MHz
b: 5 MHz
c: 15 MHz
d: 25 MHz

13. The amount of beam divergence from a crystal is pri- frequency and crystal size
"家的爱"
(Jiā de
marily dependent on the: ài)

14. Penetration of ultrasonic waves in a material is nor- 1 Mhz
mally the function of test frequency used. The great-
est depth of penetration is provided by a frequency of
a: 1 MHz
b: 2.25 MHz
c: 5 MHz
d: 10 Mhz

15. When an ultrasonic beam passes through the inter- refraction
face between two dissimilar materials at an angle, a
new angle of sound travel takes place in the second
material due to:

16. Figure 2 illustrates a contact test on. 203mm (8 in) alu- The initial pulse or front
minum block. A discontinuity is located 152mm (6in) surface indication
from the front surface. The display representation for



, ASNT ULTRASONIC LEVEL I EXAM NEWEST 2025 ACTUAL EXAM COMPLETE 170 QUESTIONS AND
CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+


this is shown to the right. What does indication A
represent?
A. The initial pulse or front surface indication
B. the first discontinuity indication
C. The first back surface reflection
D. Baseline

17. In figure 2, indication B represents: the first discontinuity indi-
A: the initial pulse or front surface indication cation
B. the first discontinuity indication
C: the first back-surface reflection
D: baseline

18. In figure 2, indication C represents the: first back surface reflec-
"家的爱"
A: second back surface reflection tion
(Jiā de
B: first discontinuity indication ài)
C: second indication of the discontinuity
D: first back surface reflection

19. In figure 2, indication D represents the: second indication of the
A: first discontinuity indication discontinuity
B: second indication of the discontinuity
C: first back-surface reflection
D: second back-surface reflection

20. In figure 2, indication E represents the: second back surface re-
A: first discontinuity indication flection
B: second indication of the discontinuity
C: first back-surface reflection
D: second back-surface reflection

21. two times




, ASNT ULTRASONIC LEVEL I EXAM NEWEST 2025 ACTUAL EXAM COMPLETE 170 QUESTIONS AND
CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+


The velocity of longitudinal waves is approximately
the velocity of shear waves in the same ma-
terial.

22. Figure 3 illustrates an immersion test of a 76 mm (3 in) The initial pulse
block of aluminum with a discontinuity located 51 mm
(2 in) below the surface. The display pattern is shown
also. What does indication A represent? Assume no
sweep delay is used.
A: first front surface indication
B: the initial pulse
C: the first discontinuity indication
D: the first back-surface indication
"家的爱"
23. In figure 3, indication B represents the: First front surface indica-
(Jiā de
A: first front surface indication tion ài)
B: the initial pulse
C: the first discontinuity indication
D: the first back-surface indication

24. In figure 3, indication C represents: first discontinuity indica-
A: first front surface indication tion
B: first discontinuity indication
C: first back-surface reflection
D: second front surface indication

25. In figure 3, indication D represents the: first back surface reflec-
A: first discontinuity indication tion
B: first back surface reflection
C: second front surface indication
D: second discontinuity indication

26.

Document information

Uploaded on
February 19, 2025
Number of pages
31
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$15.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
QuickFixer
3.6
(19)
Sold
2073
Followers
7
Items
1202
Last sold
3 months ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions